• Title/Summary/Keyword: Anion Concentration

Search Result 507, Processing Time 0.024 seconds

Continuous dialysis of selected salts of sulphuric acid

  • Bendova, Helena;Snejdrla, Pavel;Palaty, Zdenek
    • Membrane and Water Treatment
    • /
    • v.1 no.3
    • /
    • pp.171-179
    • /
    • 2010
  • The transport of selected salts of sulphuric acid (cobalt, copper, iron(II), manganese, nickel and zinc sulphate) through an anion-exchange membrane Neosepta-AFN was investigated in a counter-current continuous dialyzer at various salt concentrations and volumetric liquid flow rates. The basic transport characteristics - the rejection coefficient of salt and the permeability of the membrane - were calculated from measurements at steady state. The salt concentration in model mixtures was changed in the limits from 0.1 to 1.0 kmol $m^{-3}$ and the volumetric liquid flow rate of the inlet streams was in the limits from $8{\times}10^{-9}$ to $24{\times}10^{-9}m^3\;s^{-1}$. Under the experimental conditions given, the rejection coefficient of salts tested was in the range from 65% to 94%. The lowest values were obtained for iron(II) sulphate, while the highest for copper sulphate. The maximum rejection of salt was reached at the highest volumetric liquid flow rate and the highest salt concentration in the feed. The permeability ($P_A$) of the Neosepta-AFN membrane for the individual salts was in the range from $0.49{\times}10^{-7}m\;s^{-1}$ to $1.8{\times}10^{-7}m\;s^{-1}$ and it can be described by the following series: $P_{FeSO_4}$ < $P_{NiSO_4}$ < $P_{ZnSO_4}$ < $P_{CoSO_4}$ < $P_{MnSO_4}$ < $P_{CuSO_4}$. The permeability of the membrane was strongly affected by the salt concentration in the feed - it decreased with an increasing salt concentration.

A Study of the Adsorption Behavior of Organic Acids by Polymeric Adsorbents (고분자 흡착제에 대한 유기산의 흡착성에 관한 연구)

  • Dai Woon Lee;In Ho Lee;Dal Ho Kim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.483-494
    • /
    • 1988
  • The adsorption behavior of aromatic acids on Amberlite XAD-4 resin was investigated by measuring the distribution coefficient by batch method. The adsorption of solutes on XAD-4 was affected by the several factors such as, analyte concentration, the pH of solution and concentration of pairing ion. The enhanced adsorption of solutes on XAD-4 in the presence of tetraalkylammonium salt as an ion pairing reagent, referred to as ion interaction, was suggested to follow a double layer model where the pairing ion occupies a primary layer at the adsorbent while the solute anion and other anions in the system comlpete for the secondary layer. Therefore, the ability of an ion pairing reagent to enhance solute adsorption depended significantly on the type and concentration of counter-ion and co-anion accompanying the ion pairing reagent or salt used for ionic strength control. In addition, a good linear relationship between the logarithm of capacity factors measured by batch and elution method as a function of the concentration of ion pairing reagent and methanol can be used to predict the retention in elution method on the basis of capacity factors measured by batch method.

  • PDF

A Study on the Chemical characteristics of Anion Components and Metallic Elements of PM10 in Miryang and Changwon (밀양·창원지역의 PM10 중 음이온 성분 및 금속성분의 화학적 특성에 관한 연구)

  • Suh Jeong-Min;Jeon Bo-Kyung;Choi Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1049-1058
    • /
    • 2004
  • PM10 concentration of total 48 samples collected from 4 sites (the root of Miryang University, Sangnam township Office in Miryang. the root of Changwon elementary school, and Junam reservoir in Changwon) turned out to range from 42.29 to 69.49{\mu}g/m^{3}$, and the average concentration was the root of Changwon elementary school $(69.49{\mu}g/m^{3})$>the root of Miryang university $(58.59{\mu}g/m^{3})$>Junam reservoir $(43.56{\mu}g/m^{3})$>Sangnam township Office $(42.29{\mu}g/m^{3}).> In particular, Junam reservoir, the Clean Area, had a slightly higher value than Sangnam township Office. It was thought although the site was plane and windy without pollutants around. it had a higher concentration value influenced by external factors including bigger population and a northeasterly wind due to a newly-established industrial complex nearby. As for water-soluble ions among PM10 particle collected in Miryang and Changwon area, SO42- accounted for $50{/%}$ and NO3-, was $35{\%}$, and the concentration order was S042->N03->Cl->F-. As for the average concentration of metallic components among PM10 particle collected in Miryang and Changwon area. the root of Changwon elementary school had the AI concentration, Fe concentration and Zn concentration 4 times, 3 times and 1.5 times that of Junam reservoir, respectively. The root of Miryang University had the AI concentration 2 times that of Sangnam township Office, and had Fe concentration and Zn concentration $1.2\~1.5$ times those of Sangnam township Office. When it comes to the relation between metallic elements and meteorological factors in Changwon area, the highest coefficient of correlation was between temperature and humidity with 0.92, and temperature and wind speed turned out in the reverse correlation. The coefficient of correlation between Al and Cr was as high as 0.78. Among metallic elements, the coefficient of correlation between Cu and Pb, Cd, Al were 0.84, 0.85, 0.79, respectively. It is thought that the high coefficient of correlation between Cu and Pb is ascribed to busy traffic and wind in the urban areas, Sammun-dong and Gagok-dong in Miryang. Meanwhile, the coefficients of correlation between Fe and Cu, Al, Zn, Cd, Pb were in the reverse correlation. These coefficients of correlation are attributed to the difference in pollutant sources, rather than difference in pollutant and non-pollutant.

Liquid Chromatography of Aromatic Sulfonic Acids by Tetramethylammonium Bromide (Tetramethylammonium Bromide를 이용한 방향족 술폰산들의 액체크로마토그래피)

  • Oh, Hae-Beom
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.9
    • /
    • pp.793-799
    • /
    • 1993
  • Ion-pair model was predominated over ion-interaction model in the retention mechanism of analytes when tetramethylammonium bromide (TMAB) was used as a counter-ion in the investigation of aromatic sulfonic acids on the reversed-phase liquid chromatography by $C_{18}$ column as a stationary phase. The capacity factors of analytes were influenced by the type and concentration of counter-ions, concentrations of methanol and co-anion, types and position of functional group, and the pH mobile phase. Components of analyte mixture could be separated under the optimum conditions by this method.

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

A Comparative Study on the Chemical Compositions of Precipitations in Sungnam City of Kyunggi Province, Inchon City, Kangneung City of Kangwon Province, and Chongwon-gun of Chungbuk Province (경기도 성남시, 인천시, 강원도 강릉시, 충북 청원군 강수의 화학적 성분에 관한 비교 연구)

  • 박국태;문경언
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.285-294
    • /
    • 1995
  • A comparative study on the chemical compositions of precipitations from February 1993 to April 1993 in Sungnam city of Kyunggi province, Inchon city, Kangneung city of Kangwon province, and Chongwon-gun of Chungbuk province has been performed. The metal cation and anion concentrations were measured by atomic absorption spectrometer and ion liquid chromatography, respectively. pH/Ion meter and direct nesslerization method were used for the concentration measurements of $H^+$ and $NH^{4+}$ ions, respectively. The quantitative orders of the cation and anion average concentrations, correlation coefficients between the ion concentrations, and pH values are used for chemical analysis on the environmental pollution and pollutant sources in the urban, surburban, seaside, and rural areas of the Korean Peninsula.

  • PDF

Determination of Impurities in Uranium Dioxide by Neutron Activation Analysis (중성자방사화분석법에 의한 이산화우라늄중의 불순물정량)

  • Nak Bae Kim;Hae-Ill Bak;Chul Lee
    • Nuclear Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.237-244
    • /
    • 1981
  • The preliminary concentration of trace elements in uranium dioxide using an anion exchange resin is presented for neutron activation analysis. The uranyl solution in sulfuric acid is adjusted to the acidity of about pH 2.7 and loaded on a column of the anion exchange resin. An appropriate volume of eluates obtained from the column shows good recoveries of trace elements. By combining this preconcentration with a radiochemical separation scheme, which was developed for the determinations of impurities in aluminum, it is possible to determine 21 trace elements in reactor grade uranium dioxide.

  • PDF

Preparation of Tantalum Anodic Oxide Film in Citric Acid Solution - Evidence and Effects of Citrate Anion Incorporation

  • Kim, Young-Ho;Uosaki, Kohei
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.163-170
    • /
    • 2013
  • Tantalum anodic oxide film was prepared in citric acid solution of various concentrations and the prepared Ta anodic oxide film was characterized by various electrochemical techniques and X-ray photoelectron spectroscopy (XPS). The prepared Ta anodic oxide film showed typical n-type semiconducting properties and the dielectric properties were strongly dependent on the citric acid concentration. The variation of electrochemical and electronic properties was explained in terms of electrolyte anion incorporation into the anodic oxide film, which was supported by XPS measurements.

Effect of Propolis on the Activity of Antioxidant Enzymes in Rat Liver Irradiated by X-ray

  • Lee, Ji-Hoon;Ji, Tae-Jeong;Seo, Eul-Won
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.427-433
    • /
    • 2006
  • We investigated the effect of propolis on the activity of antioxidant enzymes in rat liver exposed by X-ray irradiation. The dosage of propolis showed the effect of lowering the concentration of superoxide anion in irradiated rat liver, suggesting that propolis has a significant role to remove superoxide anion as an antioxidant and/or by activating the antioxidant enzyme. The activities of superoxide dismutase (SOD) and glutathione reductase (GR), disturbed by X-ray irradiation, were restored in 30 days to normal status in the group which dosed propolis before X-ray irradiation. Interestingly, catalase (CAT) and glutathione peroxidase (GPOX) activities were highly increased with feeding propolis to rat compared to untreated group, whereas glutathione s-transferase (GST) activity was little affected. Taken together, it suggests that the propolis has a protective role in the rat liver cells against X-ray irradiation by increasing and recovering the activities of antioxidant enzymes.

  • PDF

A Study on the Well-being Technique Natural Dyeing with Natural Resources (2) -Effect of Monazite Treatment on the Cotton Fabric with Natural Dyeing using Perilla frutescens var. acuta - (천연물질을 활용한 웰빙기법 천연염색에 관한 연구 (2) -소엽염색 면직물의 모나자이트 처리효과-)

  • Kim, Sang-Yool
    • Fashion & Textile Research Journal
    • /
    • v.12 no.2
    • /
    • pp.240-245
    • /
    • 2010
  • The effects of monazite and fixing agents on cotton fabric dyed with Perilla frutescens var. acuta extract were investigated. The proper monazite treatment concentration, temperature and time were 10%(o.w.b.), $50^{\circ}C$ and 60minutes. By various fixing agent treatment, $FeSO_4$ showed a relatively high K/S value and the order of K/S value decreased as follows, cation surface active agents, soybean and NaCl. And the monazite and $FeSO_4$ fixing agent showed higher anion emissity than those of untreated cotton and other fixing agents. The cotton fabrics showed improved color fastness by monazite and fixing agents treatments with the exception of light fastness. And the cotton fabrics fixed with fixing agents were showed effective bacterial reduction with the exception of NaCl.