• 제목/요약/키워드: Angular dependence factor

검색결과 12건 처리시간 0.019초

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구 (Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head)

  • 조성구;최상현;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.165-171
    • /
    • 2006
  • 국내에서는 현재 물리적 인형 모의피폭체와 수십 개의 소형 MOSFET 선량계를 이용하여 유효선량(Effective Dose)을 실시간으로 정확하게 측정할 수 있는 시스템을 개발 중에 있다. 이때 사용되는 MOSFET 선량계는 그 크기가 매우 작으며, 상대적으로 높은 민감도를 가지고 선량을 실시간으로 측정할 수 있다는 장점이 있는 반면, 검출부위가 조직등가 물질이 아닌 실리콘으로 이루어져 있어 저에너지 광자에 대하여 적절한 보정이 필요하다. 본 연구에서는 몬테칼로 전산모사 방법을 사용하여 증기발생기 수실 내부의 에너지 스펙트럼에 대한 MOSFET 선량계의 선량보정인자 값들을 계산하였으며, 이렇게 계산된 보정인자 값들을 선행 연구에서 구한 값, 즉 0.662 MeV와 1.25 MeV의 광자만을 이용하여 구한 선량보정인자 값들과 비교하여 보았다. 비교 결과, 두 서로 다른 조건에서의 선량보정인자들은 큰 차이를 보이지 않았으며$(\leq1.5%)$, 따라서 선행 연구에서 구한 선량보정인자들을 원자력발전소의 증기발생기 수실에 그대로 적용하여도 큰 문제가 없음을 알 수 있었다. 또한, 증기발생기 수실에 대하여 결정된 선량보정인자들을 실측된 MOSFET 선량계의 선량값들에 적용하여 선량보정에 따라 유효선량이 어느 정도 변화하는 가를 확인한 결과, 유효선량은 선량보정인자를 적용할 경우가 적용하지 않을 경우에 비해 약 7% 정도 낮게 평가됨을 알 수 있었다.