• 제목/요약/키워드: Angular Dependence

검색결과 122건 처리시간 0.027초

OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가 (Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • 식품보건융합연구
    • /
    • 제4권1호
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.

Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

  • Okazaki, Tohru;Hayashi, Hiroaki;Takegami, Kazuki;Okino, Hiroki;Kimoto, Natsumi;Maehata, Itsumi;Kobayashi, Ikuo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.229-236
    • /
    • 2016
  • Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.

Spin Transfer Torque in Ferromagnet-Normal Metal-Antiferromagnet Junctions

  • Lee, Hyun-Woo;Yang, Hyun-Soo
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.92-96
    • /
    • 2011
  • This study investigated theoretically the properties of the spin transfer torque acting on a ferromagnet in a ferromagnet-normal metal-antiferromagnet junction. Earlier work showed that the angular dependence of the spin transfer torque can be a wavy-type if the junction satisfies a special symmetry. This paper reports a simple model analysis that allows a derivation of the wavy angular dependence without taking advantage of the symmetry. This result suggests that the wavy angular dependence can appear even when the symmetry is broken. As an illustration, the angular dependence was calculated as a function of the degree of the compensation at the normal metal-antiferromagnet interface. The implications of the result for the current-induced magnetization precession are discussed.

군사용 방사선 계측기 PDR-1K 반응도 평가 : 방향 및 에너지 의존성을 중심으로 (Evaluation for Performance of a Military Radiation Detecter PDR-1K : Focused on Dependence of Angular and Energy)

  • 박원석;최준혁;정도영;김장오;민병인
    • 한국군사과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.300-305
    • /
    • 2017
  • In this paper, we performed a evaluation for angular and energy dependence of military radiation detector PDR-1K. Its measuring range is divided into two section, low and high, and each range has a GM tube separately owing to broad scale. We observed a change in relative angular reactivity within 0.928 ~ 1.188 in low range and within 0.743 ~ 1.000 in high range from $-90^{\circ}$ to $+90^{\circ}$. The evaluation for energy dependence appeared a relative reactivity within 0.892 ~ 1.000 above 83 keV. This means PDR-1K isn't possible to use below 83 keV of radiation energy. It is possible to provide response information to user and to increase reliability of radiation measurement through this paper.

말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산 (A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom)

  • 김종수;윤석철;김장렬;김광표
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.263-271
    • /
    • 1996
  • ANSI N13.32에서는 선량제의 방향에 따른 반응도가 성능시험의 합격판정의 범주는 아니지만 이에 관한 연구를 요구하고 있다. 본 연구에서는 ANSI N13.32의 말단팬텀 즉, 손가락과 손목팬텀내의 $7mg/cm^2$ 깊이에서 MCNP 코드를 사용하여 단일에너지를 가진 광자 및 ISO narrow X-선 빔에 대하여 선량당량환산인자와 방향의존성인자를 도출하였다. X-선 빔에 대하여는 이들 데이터를 B. Grosswent의 연구 결과와 비교하였다. 그 결과 선량당량환산인자는 낮은 에너지 영역에서 최대 7%를 그리고 다른 에너지 영역에서는 2% 이내였으며, 방향의존성인자는 최대 3% 정도로 잘 일치하였다. 또한 60keV 이하의 낮은 에너지 영역에서 발생된 방향의존성인자는 손가락 팬텀의 경우에 주축을 따라 수평회전각이 증가할수록 감소하지만 그 에너지 영역 이상에서 $90^{\circ}$까지는 증가하고 있음을 알 수 있었다.

  • PDF

NiFe/MnIr 박막에서 교환 바이어스의 각도 의존성 연구 (Angular Dependence of Exchange Bias in NiFe/MnIr Bilayers)

  • 윤석수;김동영
    • 한국자기학회지
    • /
    • 제27권1호
    • /
    • pp.30-34
    • /
    • 2017
  • 본 연구에서는 교환 결합력을 갖는 강자성/반강자성(AF) 박막에서 단자구 모델을 사용하여 교환 바이어스($H_{ex}$)의 각도 의존성을 계산하였으며, NiFe/MnIr 박막에서 측정한 결과와 비교 분석하였다. AF층 두께가 임계 두께 이상에서($t_{AF}$ > $t_c$) 계산한 $H_{ex}$의 각도 의존성은 전형적인 일방 이방성 특성을 보였으나, $0.5t_c$ < $t_{AF}$ < $t_c$에서는 $90^{\circ}$ 근처의 특정한 각도에서 AF 스핀의 고정에 의한 독특한 $H_{ex}$의 각도 의존성을 보였다. NiFe/MnIr(20 nm) 박막에서 측정한 $H_{ex}$의 각도 의존성은 전형적인 일방 이방성 특성을 보였으나, NiFe/MnIr(4 nm) 박막에서는 일방 이방성 특성과 AF 스핀의 고정에 의한 특성이 혼합된 결과를 보였으며, 이는 다결정 구조를 갖는 MnIr의 입도 분포 특성으로 설명되어짐을 알 수 있었다.

Dependence of solar proton peak flux on 3-dimensional CME parameter

  • Park, Jinhye;Moon, Yong-Jae;Lee, Harim
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.64.1-64.1
    • /
    • 2015
  • In the present study, we examine the dependence of solar proton peak flux at SOHO and STEREO on 3-D CME parameters (radial speed, angular width, and longitudinal angular separation between its source region and the magnetic footpoints of spacecraft). For this we consider 38 proton enhancements of 16 SEP events observed by SOHO, STEREO-A, and/or B from 2010 August to 2013 June. As a result, we find that the enhancements are strongly dependent on these three parameters. The correlation coefficient between proton peak flux and CME speed is about 0.42 for the cases the footpoints are located inside the lateral boundaries of angular widths, while there is no correlation for the events outside the boundaries. The correlation coefficient between peak flux and angular separation is -0.51. We find that most of strong proton events occur when their angular separations are closer to zero, supporting that most of the proton fluxes are generated near the CME noses rather than their flanks.

  • PDF

영상의학과에서 사용되는 광자극 형광선량계와 전자식 개인선량계의 방향 의존성 비교 (The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology)

  • 권순무;박정규;김부순
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권3호
    • /
    • pp.463-470
    • /
    • 2015
  • 최근 개인선량계로 사용이 증가하고 있는 수동형 선량계인 OSLD와 능동형 선량계인 EPD의 상대 반응도(relative response), 측정 불확도(uncertainty of measurement)를 계산하여 방향의존성(angular dependence)을 비교, 분석하였다. OSLD는 수평, 수직방향의 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위에서 평균 상대 반응도는 0.97, 0.95의 작은 변화를 보였고 방향의존성에 대한 불확도는 0.65, 0.62로 전체 불확도에 미치는 영향은 미미한 것으로 판단되었다. EPD는 $0^{\circ}{\sim}{\pm}60^{\circ}$ 범위에서 수평, 수직방향 평균 상대 반응도는 0.94, 0.97로 확인되어 IEC 61526 규정을 만족하였다. 방향의존성에 대한 불확도는 수평, 수직방향에서 0.44, 0.40로 전체 불확도에 미치는 영향은 미미하였다. 그러나 수평방향에서 $+90^{\circ}$, $-90^{\circ}$ 방향의 상대 반응도는 0.60, 0.37이고 수직방향에서 $+90^{\circ}$ 방향의 반응도는 0.06으로 반응도의 큰 변화를 관찰할 수 있었다. OSLD의 방향 의존성은 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위까지 EPD에 비해 우수하였으며 EPD의 경우 구조적 특징으로 반응도가 급변하는 특정방향이 존재하였다. 따라서 수동형선량계와 보조선량계의 병행사용이 개인피폭선량측정의 정확도를 기할 수 있을 것으로 판단된다.

열형광선량계(도시메터타입 : PB-3)의 방향의존성에 관한 연구 (A Study on the Angular Dependence of the PB-3 Dosimeter Using Teledyne 9150 TLD Reader System)

  • 손중권;김종경;윤석철
    • Journal of Radiation Protection and Research
    • /
    • 제19권3호
    • /
    • pp.189-198
    • /
    • 1994
  • Teledyne 9150 판독장치에서 사용되는 PB-3 열형광선량계의 방향의존성에 관한 실험을 실시하였고 ANSI N13.11-1992에 의거하여 성능실험을 실시하였다. 조사선원은 $^{137}Cs$과 X선이었다. Teledyne 9150 선량판독장치는 $0^{\circ}$에서는 모든 경우에 방향의존성에 대한 성능시험범주를 만족하였다. 그러나 저에너지 X선의 경우, ${\pm}60^{\circ}$에서는 방향의존성에 대한 성능시험범주를 만족할 수 없었으며 $^{137}Cs$은 모든 경우에 방향의존성에 대한 성능시험범주를 만족하였다.

  • PDF

Angular Spectrum of the Spontaneous Emission from Dye Molecules Near a Boundary

  • Choi, Hyun-Ho;Kim, Hyoung-Joo;Noh, Jae-Woo;Park, Dae-Yoon;Jhe, Won-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제6권1호
    • /
    • pp.1-4
    • /
    • 2002
  • We studied experimentally the angular spectrum of the light emitted from dye Molecules near a plane boundary. It is confirmed that the molecules near the boundary can emit light into the evanescent wave mode, and the light emission with the angle greater than the critical angle is detected with good accuracy. The angular spectrum of the spontaneous radiation is measured, and the spectrum shows contributions from the molecules both near and far away from the boundary. The polarization dependence and the pumping angle dependence are also measured. The experimental results are in good agreement with quantum theory.