• Title/Summary/Keyword: Angle probe

Search Result 229, Processing Time 0.031 seconds

A development of $LiNbO_3$ probe sensor for detecting partial discharge (부분방전 전계 측정용 $LiNbO_3$ 프루브 센서 제작)

  • Kang, W.J.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1041-1043
    • /
    • 1999
  • In this work, a possible new PD detection technique, based on the electro-optic effect, has been proposed. A proto-type probe sensor for detection partial discharge is made by $LiNbO_3$ Pockels cell, diachroic sheet polarizer and right-angle prism. The Mach-Zehnder interferometer system is proposed by using this sensor and this system is applied to detecting high electric field. we show the characteristic of the proto-type probe sensor and the design of a proposed probe type sensor.

  • PDF

Determination of the Position of the Airspeed Probe Using CFD (전산유동해석에 의한 비행선 풍속계 설치 위치 선정)

  • Ok Honam;Chang Byeong-Hee;Lee Yung-Gyo;Oh Soo-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.164-170
    • /
    • 2002
  • Numerical analysis of the flowfield around a 50-meter class airship is performed to determine the optimal position for the airspeed probe installation. The turbulent flow around the hull with gondola is analyzed to examine the characteristics of the data measured by the probe attached to the gondola, and they turned out to show the nonlinear relation between the freestream and measured angles of attack and be influenced by the Reynolds number. New position of the hull nose was proposed and the effect of various factors on the flowfield around the nose was also examined. The analysis with a panel method showed that the effect of empennage was negligible, and the effect of gondola and boundary layer thickness had also little impact. It was shown that the freestream angle of attack would be the only independent variable for the probe position around the hull nose in constructing the calibration matrix.

  • PDF

Design and Fabrication of a 3-dimensional Diagnostic Ultrasonic Probe (3차원 입체 영상 진단용 초음파 프로브의 설계 및 제작)

  • Eun, Hong;Lee, Su-Sung;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.766-771
    • /
    • 2002
  • In this study, we have developed a 3-dimensional diagnostic ultrasonic sector probe using a convex type ultrasonic probe with 128 active elements. The probe was made to operate at the center frequency of 4.5㎒ with the bandwidth of 66%. The driving part was designed to rotate the axis of the convex probe by means of a step motor equipped with reduction gears and spur gears attached to the motor so that the probe could enable us to acquire a series of 2-dimensional images to construct a 3-dimensional image. Acoustic cover of the probe was made of polymers to have the same radius of rotation as that of the convex probe. The controllability of the rotation angle and the structural stability of the probe were confirmed through experimental 3-dimensional images obtained using the developed 3-dimensional sector probe.

Polarization State of Scattered Light in Apertureless Reflection-mode Scanning Near-Field Optical Microscopy

  • Cai, Yongfu;Aoyagi, Mitsuharu;Emoto, Akira;Shioda, Tatsutoshi;Ishibashi, Takayuki
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.317-320
    • /
    • 2013
  • We studied the polarization state in an apertureless scanning near-field microscopy (a-SNOM) operating in reflection mode by using three-dimensional Finite-difference Time-domain (FDTD) method. As a result, the electric field around tip apex in the near-field region enhanced four times stronger than the incident light for ppolarization when the tip-sample separation was 10 nm. We find that the p- and s-polarization state is maintained for the scattered light when the probe is perpendicular to the sample. When the probe is not perpendicular to the sample, the polarization state of scattered light will rotate an angle that equals to the inclination angle of probe with p-polarization illumination. On the other hand, the polarization state will not rotate with s-polarization illumination.

Reliability and validity of rehabilitative ultrasound images obtained using a hands-free fixed probe in measuring the muscle structures of the tibialis anterior and the gastrocnemius

  • Choi, Mun-Sang;Shin, Jang-Hoon;Park, Hye-Kang;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.194-201
    • /
    • 2019
  • Objective: This study aimed to investigate the reliability and validity of muscle thickness (MT) and pennation angle (PA) measurements of the ankle muscle, including the tibialis anterior (TA) and the medial gastrocnemius (MGCM), using a hands-free fixed probe and to compare it with the conventional linear probe. Design: Observational inter-rater reliability study. Methods: Thirty-three healthy subjects (20 male, 13 female) were included. In all subjects, ultrasound images were acquired from the TA and MGCM using a hands-free fixed probe and a conventional linear probe in random sequence by two examiners at two time-points within a 7-day interval. MT and PA were calculated on the taken images. Intra-class correlation coefficients (ICC), 95% confidence intervals, standard error of measurement and the Pearson's correlation coefficient were used to estimate reliability and validity. And also, Bland-Altman plots were generated for a visual representation of MT and PA at the TA and MGCM. Results: The ICC for all intra-rater reliability was 0.943 to 0.995 and that for all inter-rater reliability was 0.928 to 0.993, indicating excellent reliability. A significantly high correlation was observed between MT and PA at the TA and MGCM with use of the hands-free fixed probe and the conventional linear probe (r>0.938; p<0.001). Conclusions: The hands-free fixed probe provided excellent images for measurement of the MT and PA of the TA and MGCM and is a useful device for making clinical measurements of muscle structure without grasping of the probe.

Radiation Characteristics of a Probe-Fed Microstrip Patch Antenna on a Finite Grounded High Permittivity Substrate

  • Kwak, Eun-Hyuk;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1738-1745
    • /
    • 2015
  • Radiation characteristics of a probe-fed rectangular microstrip patch antenna printed on a finite grounded high permittivity substrate are investigated systematically for various square grounded dielectric substrate sizes with several thicknesses and dielectric constants by experiment and full wave simulation. The effect of the substrate size on the radiation characteristics of a rectangular patch antenna is mainly determined by the effective dielectric constant of surface waves on a grounded dielectric substrate. As the effective dielectric constant of surface waves increases, the substrate sizes for the maximum broadside gain and the required onset for a large magnitude of squint angle decrease, while the variations of the broadside gain, the front-to-back ratio, and the magnitude of squint angle versus the substrate size increase due to the increase of the power of the surface wave.

Diffraction by a sub-wavelength-sized aperture in a metal plane (파장보다 작은 금속 구멍을 통한 회절)

  • ;;Arturo Chavez-Pirson
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.164-165
    • /
    • 2000
  • 구멍에 의한 빛의 회절은 광학의 기본적인 문제로서, 최근 근접장 광학(Near-Field Optics)의 발전과 더불어서 파장보다 작은 구멍에서 일어나는 빛의 회절에 대한 관심이 고조되고 있다.$^{(1)(2)(3)}$ 본 연구에서는 그동안 주로 이론적으로 다루어지고 있던 파장보다 작은 금속 구멍을 통한 빛의 회절에 대해 실험결과들을 보고한다. 회절된 빛의 먼장(Far-field)과, 근접장(Near-field)을 모두 측정하기 위해서 고체각 주사기(Solid angle scanner)와 근접장 주사 광학 현미경(Near-field Scanning Optical Microscopy)이 사용되었다. 고체각 주사기(Solid angle scanner)를 사용하여 반구면 위에서의 빛의 이차원 세기 분포가 다양한 편광 상태에 따라서 측정되었고$^{(4)}$ 근접장 탐침(NSOM probe)으로 작은 금속 구멍주변을 주사함으로서 근접장이 측정되었다. 작은 구멍은 최근에 개발된 고출력 근접장 광섬유 탐침(High-power near-field fiber probe)구조를 이용하여 제작되었다.$^{(5)}$

  • PDF

Calibration and Flight Test Results of Air Data Sensing System using Flush Pressure Ports (플러시 압력공을 사용한 대기자료 측정장치의 교정 및 비행시험 결과)

  • Lee, Chang-Ho;Park, Young-Min;Chang, Byeong-Hee;Lee, Yung-Gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.531-538
    • /
    • 2017
  • A flush air data sensing system, which can predict flight speed, angle of attack, and angle of sideslip of the aircraft is designed and manufactured for a small UAV. Two kinds of flush pressure ports, four ports and five ports, are tapped at the same section of fuselage nose-cone. Calibration pressure data at flush ports are obtained through computations for the total aircraft by using Fluent code. Angle of attack, angle of sideslip, total pressure, and static pressure are represented with 4th-order polynomial function and calibration coefficient matrix is obtained using least square method with calibration pressure data. Flight test showed that flight speed, angle of attack, and sideslip angle predicted by four flush ports and five flush ports compared well with those by five-hole probe installed for data comparison. Especially four flush ports revealed nearly same results as those by five flush ports.

Flow and Heat Transfer Characteristics due to the Variations of the Angle of Attack at the Vortex Generators located behind a Circular Cylinder (원주 후미에 부착된 와동발생기의 영각 변화에 따른 유동 및 열전달 특성)

  • 하홍영;홍철현;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.439-449
    • /
    • 2002
  • Experimental investigations of the flow structure and heat transfer enhancement in a channel with a built-in circular cylinder and a wing-let type vortex generator are presented. Without any vortex generators, relatively low heat transfer takes place in the downstream of the circular cylinder where is a recirculation region with low velocity fluid is formed. However with a wing-let type longitudinal vortex generator in the wake region behind the cylinder, heat transfer in the region can be enhanced. In order to control the strength of longitudinal vortices, the angle of attack of the vortex generators is varied from $20^{circ} to 45^{\circ}$, but spacings between the vortex generations are fixed to be 5 mm. The 3-dimensional mean velocity field downstream of the vortex generator is measured by a five-hole pressure probe, and the hue-capturing method using thermochromatic liquid crystals has been used to provide the local distribution of the heat transfer coefficient. The vorticity field and streamwise velocity contour are obtained from the velocity field. Streamwise distributions of averaged Stanton number on the measurement planes show very similar trends for all the experimental cases($\beta=20^{circ}, 30^{circ} and 45^{\circ}$). Circulation strength and heat transfer coefficient have the maximum values when the angle of attack($\beta$) is $30^{\circ}$.

Study on Frictional Characteristics of Sub-micro Structured Silicon Surfaces (서브 마이크로 구조를 가진 실리콘 표면의 마찰 특성 연구)

  • Han, Ji-Hee;Han, Gue-Bum;Jang, Dong-Yong;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.92-97
    • /
    • 2017
  • The understanding of the friction characteristics of micro-textured surface is of great importance to enhance the tribological properties of nano- and micro-devices. We fabricate rectangular patterns with submicron-scale structures on a Si wafer surface with various pitches and heights by using a focused ion beam (FIB). In addition, we fabricate tilted rectangular patterns to identify the influence of the tilt angle ($45^{\circ}$ and $135^{\circ}$) on friction behaviour. We perform the friction test using lateral force microscopy (LFM) employing a colloidal probe. We fabricate the colloidal probe by attaching a $10{\pm}1-{\mu}m$-diameter borosilicate glass sphere to a tipless silicon cantilever by using a ultraviolet cure adhesive. The applied normal loads range between 200 nN and 1100 nN and the sliding speed was set to $12{\mu}m/s$. The test results show that the friction behavior varied depending on the pitch, height, and tilt angle of the microstructure. The friction forces were relatively lower for narrower and deeper pitches. The comparison of friction force between the sub-micro-structured surfaces and the original Si surface indicate an improvement of the friction property at a low load range. The current study provides a better understanding of the influence of pitch, height, and tilt angle of the microstructure on their tribological properties, enabling the design of sub-micro- and micro-structured Si surfaces to improve their mechanical durability.