• Title/Summary/Keyword: Angle of Inclination

Search Result 746, Processing Time 0.028 seconds

A Study on the MPPT Control of 3kW Grid-connection Photovoltaic Generation System (3kW 계통연계형 태양광발전시스템의 MPPT제어에 관한 연구)

  • Kim, K.B.;Lim, H.W.;Baek, H.L.;Cho, G.B.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.340-342
    • /
    • 2001
  • This paper presents a utility interactive photovoltaic generation system with the angle of inclination and direction. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. also, This System is able to alteration the angle of inclination and direction. Hence this paper discusses only points that might be useful for application.

  • PDF

Modal Analysis of Composite Trapezoidal Plates Undergoing In-plane Translational Acceleration (면내 병진 가속을 받는 복합재 사다리꼴 평판의 진동 해석)

  • Lim, Hong-Seok;Yoo, Hong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1486-1491
    • /
    • 2003
  • A modeling method for the modal analysis of a composite trapezoidal plate undergoing in-plane translational acceleration is presented in this paper. The equations of motion for the plate are derived and transformed into a dimensionless form. The effects of the inclination angles, fiber orientation angle and the acceleration on the modal characteristics of the plate are investigated.

A FDTD Analysis for the Slanted Metallic Boundaries (기울어진 금속 경계면에 대한 FDTD 해석)

  • 이윤경;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.278-284
    • /
    • 2001
  • In this paper, the slanted metallic boundaries is analyzed for the triangular cell grid method and compared with staircase approximation. Specially, this paper is derived an error range to the angle of inclination between the metal and the dielectric from the triangular cell grid method. That result, when the angle of inclination is from 30˚ to 60˚, the triangular cell grid method improves the accuracy, the computer memory and time requirement in comparison with the staircase approximation. But, out of this range, we do not expect the accuracy because a side of cell size lengthen.

  • PDF

Natural Convection in a Three Dimensional Inclined Enclosure (경사진 3차원 밀폐 공간 내에서의 자연대류)

  • Bae Dae Seok;Kwon Oh Boong;Kim Hyun Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.168-176
    • /
    • 2005
  • In an inclined enclosure with the upper part cooled and the lower part heated, quantitative data of the temperature and velocity are obtained simultaneously using thermo-sensitive liquid crystals. Experimental results are Presented for Pr=909. aspect ratios of 1/14. 2/14 and 3/14, angle of inclination, 0$\leq$$\theta$$\leq$45 to the horizontal line. The numerical results are obtained in the same conditions as experiments by the finite volume method and its results are compared with experimental results. It is found that the number of cell is decreased with increasing the angle of inclination. and a unicell is formed at nearby 6=30$^{circ}$ which is not affected by the aspect ratio.

In -Cylinder Flow Characteristics Varying Intake Valve Lift (밸브 리프트 변화에 따른 실린더 내 흡입 공기의 유동 특성)

  • 윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.82-88
    • /
    • 1999
  • The object of this study is to find new evaluation index for in-cylinder flow chracteristics istead of current swirl, tumble coefficient using steady flow test rig on intake port system. To this end, port flow system. To this end, port flow rig test was conducted on DOHC head varying intake valve lift respectively. Finally combination angular coefficient and inclination angle were introduced as new evaluation index for in-cylinder angularflow characteristics instead of swirl and tumble coefficient.

  • PDF

A Study on Combined Effects between Swirl and Tumble Flow of Intake Port System in Cylinder Head (엔진 흡입포트 시스템 유동특성 규명을 위한 스월-텀블 합성효과에 관한 연구)

  • 윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.76-82
    • /
    • 1999
  • The object of this study is to find new evalution index for in-cylinder flow characteristics insteady of current swirl, tumble coefficient using steady flow test rig on intake port system. To this end, port flow rig test was conducted on DOHC head varying intake valve lift respectively. Finally combination angular coefficient and inclination angle were introduced as new evaluation index for in-cylinder angular flow characteristics.

  • PDF

The Experimental Study on Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe (열전소자와 PF Type 진동형 히트파이프를 이용한 냉.난방기에 관한 연구)

  • 김종수;임용빈;조원호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.741-747
    • /
    • 2004
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type oscillating heat pipe with R-142b as a work ing fluid. The experiment was performed for 16 thermoelectric modules (6 A/15 V, size: 40${\times}$40${\times}$4 mm), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc) . Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type oscillating heat pipe were 30% by volume and 30%, respectively. The maximum cooler/heater capacity were 479W (COP : 0.47) and 630W (COP : 0.9), respectively.

Resonance of Natural Convection and Heat Transfer inside a Square Cavity due to a Vibrating Wall (사각 공동구의 벽면 가진에 의한 자연 대류 유동의 공진 현상 및 열전달에 관한 연구)

  • Hur, N.;Kim, Y.;Kang, B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.483-488
    • /
    • 2001
  • In the present study a numerical simulation is performed on a natural convection inside a square cavity with a vibrating wall. The study has been conducted varying the heat transfer rate, wall excitation frequency and also the orientation of the cavity. The temperature and velocities inside the cavity was observed and also, the heat transfer coefficients on the heating wall was seen. From the results, it can be seen that the temperature inside the cavity decreases when excited with the proper frequency and the heat transfer coefficient increased with cavity inclination angle, ${\theta}$. It is also found from the results that flow resonance is occurred near the inclination angle ${\theta}=90^{\circ}$.

  • PDF

Burr formation experiment in drilling on the inclined exit surface (경사진 출구면에서 드릴 버 형성에 관한 실험적 고찰)

  • Kim B.K.;Ko S.L.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1253-1256
    • /
    • 2005
  • An Experiment was carried out to study burr minimization in drilling on the inclined exit surface. Several different drills, exit surface angles and cutting conditions were selected to determine their influences on burr formation. In drilling operation, there are not only flat exit surfaces but also inclined exit surfaces which is described as inclination angle. Inclination of exit surface causes a quiet different burr formation when comparing with flat surface. Burr formation mechanisms are analyzed according to the drill geometries and cutting conditions. Several schemes for burr minimization on inclined exit surface were proposed. Burr geometry in each drill and cutting condition are measured by laser measurement system.

  • PDF