• Title/Summary/Keyword: Angle method

Search Result 7,457, Processing Time 0.034 seconds

Ultasonic Reflection Characteristics of the Underwater Corner Reflector (수중코오너리프렉터의 초음파반사특성에 관한 연구)

  • Lee, Dae-Jae;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 1983
  • The corner reflector is used to increase the echoing area of radar targets in the air, and it can also be applied to increase the echoing area of the sonar targets under water. As the basic research for this application, the authors investigated the ultrasonic reflection characteristics under water for the corner reflector which was made of aluminum plate. The experiments were made by pulse measuring method with the magnetostrictive ferrite transducers of 28, 50 and 75KHz in the experimental water tank. The results obtained are as follows; 1. The target strength of corner reflectors were increased in proportion to the diameter and were greater at higher frequency of 75KHz than at lower frequency of 28KHz. 2. In the case of 5 corner reflectors of 150mm in diameter which have corner angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$the measured values of the maximum target strength at 75KHz were-25.0 dB, -17.2dB, -15.1dB, -13.4dB and 11.0dB, and then the number of main lobes showing the maximum target strength in the backscattering patterns were 24, 12, 8, 6 and 4, respectively. 3. When 7 corner reflector of 80mm in diameter and 90$^{\circ}$ in the corner angle was located on the minor axis of the horizontal section with directional angles of 0$^{\circ}$, 2.5$^{\circ}$, 5.0$^{\circ}$, 7.5$^{\circ}$, 10$^{\circ}$ and 12.5$^{\circ}$ against the sound beam axis, the measured values of the target strength on each position at 75KHz were -21.2dB, -21.9dB, -26.0dB, -30.5dB and -36.8dB, respectively.

  • PDF

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.

A Study on Setup for Preliminary Decision Criterion of Continuum Rock Mass Slope with Fair to Good Rating (양호한 연속체 암반사면의 예비 판정기준 설정 연구)

  • Kim, Hyung-Min;Lee, Su-gon;Lee, Byok-Kyu;Woo, Jae-Gyung
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • It can be observed that steep slopes ($65^{\circ}$ to $80^{\circ}$) consist of rock masses were kept stable for a long time. In rock-mass slopes with similar ground condition, steeper slopes than 1 : 0.5 ($63^{\circ}$) may be applied if the discontinuities of rock-mass slope are distributed in a direction favorable to the stability of the slope. In making a decision the angle of the slope, if the preliminary rock mass conditions applicable to steep slope are quantitatively setup, they may be used as guidance in design practice. In this study, the above rock mass was defined as a good continuum rock mass and the quantitative setup criterion range was proposed using RMR, SMR and GSI classifications for the purpose of providing engineering standard for good continuum rock mass conditions. The methods of study are as follows. The stable slope at steep slopes ($65^{\circ}$ to $80^{\circ}$) for each rock type was selected as the study area, and RMR, SMR and GSI were classified to reflect the face mapping results. The results were reviewed by applying the calculated shear strength to the stable analysis of the current state of rock mass slope using the Hoek-Brown failure criterion. It is intended to verify the validity of the preliminary criterion as a rock mass condition that remains stable on a steep slope. Based on the analysis and review by the above research method, it was analyzed that a good continuum rock mass slope can be set to Basic RMR ${\geq}50$ (45 in sedimentary rock), GSI and SMR ${\geq}45$. The safety factor of the LEM is between Fs = 14.08 and 67.50 (average 32.9), and the displacement of the FEM is 0.13 to 0.64 mm (average 0.27 mm). This can be seen as a result of quantitative representation and verification of the stability of a good continuum rock mass slope that has been maintained stable for a long period of time with steep slopes ($65^{\circ}$ to $80^{\circ}$). The setup guideline for a good continuum rock mass slope will be able to establish a more detailed setup standard when the data are accumulated, and it is also a further study project. If stable even on steep slopes of 1 : 0.1 to 0.3, the upper limit of steep slopes is 1 : 0.3 with reference to the overseas design standards and report, thus giving the benefit of ensuring economic and eco-friendlyness. Also, the development of excavation technology and plantation technology and various eco-friendly slope design techniques will help overcome psychological anxiety and rapid weathering and relaxation due to steep slope construction.

Types of tweezers and their culture of use (족집게(鑷)의 유형과 사용 문화)

  • KIM, Jihyeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.3
    • /
    • pp.4-23
    • /
    • 2021
  • The purpose of this study was to classify the types of tweezers used across time and to examine the social culture of periods through the use of tweezers. Chapter II summarized the terms for tweezers and looked at the use of tweezers in two cases related to the social culture and politics of a period. The first is the use of tweezers for beauty purposes. Men used tweezers as a kind of self-management to maintain their social status and power, and thus they helped develop a wide range of tweezers cultures. People with gray hair are usually old. The perception that we should step down from politics when we are aged has become strong. Therefore, politicians pulled out gray hairs with tweezers to maintain only black hair and show youth, which indicates that their social influence is still strong. The second is the use of tweezers for first aid. Chapter III classified tweezers by type during the Goryeo and Joseon periods. The tweezers are largely divided into basic and composite types. The basic type of tweezers is a form that has been continued since the Three Kingdoms Period and consists of tongs and handles, and a fixed type of tweezers with a fixed ring appeared. Composite tweezers are made by grafting earpick or multipurpose knives. Composite tweezers are all-in-one tweezers with an earpick and an all-in-one knife. Tweezers are usually all-in-one. Among the composite tweezers, rivet separation and ring separation are characterized by separation, unlike the all-in-one tweezers. The method of connecting is divided into rivets and connection rings. The all-in-one tweezers appear only during the Goryeo Dynasty and are characterized by the lifestyle that provides a glimpse of the tastes of contemporary users. The manufacturing takes shape after making a thin metal plate. Decorative techniques are carved on soft metal tweezers, such as silver and bronze with a line, point, and a pressed angle. These tweezers are presumed to have been used by the royal family or aristocrats. However, most tweezers are made of strong bronze or iron. Therefore, the majority of simple X-shaped patterns are sampled or without patterns. The biggest reason why there are such diverse types of tweezers is that the culture of tweezers was widespread regardless of the times. In addition, the basic type of tweezers has been used since the Three Kingdoms Period and has been modified and used together as necessary because the shape of tweezers is a practical daily tool. Study of metal crafts have been limited to royal objects and Buddhist crafts. We hope that research on everyday tools such as tweezers will continue to serve as an opportunity to examine the social and cultural aspects of the times in various ways.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Clinical Results of Medial Unicompartmental Knee Arthroplasty in Elderly Patients Older than 70 Years of Age (70세 이상의 고령 환자에서 시행한 내측 슬관절 단일구획치환술의 임상 결과)

  • Kim, Kyung Tae;Lee, Song;Kim, Jin Hak;Lee, Ho Young;Kim, Myung Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Purpose: To evaluate the long-term clinical results and survivorship of unicompartmental knee arthroplasty (UKA) in elderly patients older than 70 years by analyzing cases that have been implanted for >10 years ago. Materials and Methods: The long-term follow-up results were evaluated in 39 patients (46 cases) who underwent medial UKA from March 2002 to February 2004. The mean age of the patients at the time of surgery was 74.0 years, and the preoperative diagnosis was degenerative arthritis of the knee in all cases. Results: Of the 46 cases, reoperation occurred due to the complications in four cases. In 22 cases without 14 cases of death and six cases of follow-up loss, follow-up more than 10 years was possible. The mean Knee Society knee and function scores improved significantly from 53.0 and 52.5 points pre-operatively to 89.4 and 80.9 points at the last follow-up, respectively (p<0.001). The mean range of motion of the knee recovered to 132.5°, and the mean tibiofemoral angle changed to 5.9° of valgus at the last follow-up. Complications following the UKA occurred in four cases; the most prevalent complication was mobile bearing dislocation (n=2). One case of failure occurred due to aseptic loosening and degenerative arthritis of the lateral compartment, respectively. The cumulative survival rate of the implants was 95.0% at 10 years and 85.7% at 15 years. Of the 40 cases, excluding six cases of follow-up loss, 36 cases (90.0%) could be used without reoperation until death or at the last follow-up after surgery. Conclusion: These results showed the outstanding functions of the knee and satisfactory long-term survivorship after UKA. Therefore, UKA could be a useful method for the treatment of osteoarthritis of the knee in elderly patients older than 70 years of age.

Long-Term Survival Analysis of Unicompartmental Knee Arthroplasty (슬관절 부분 치환술의 장기 생존 분석)

  • Park, Cheol Hee;Lee, Ho Jin;Son, Hyuck Sung;Bae, Dae Kyung;Song, Sang Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.427-434
    • /
    • 2019
  • Purpose: This study evaluated the long term clinical and radiographic results and the survival rates of unicompartmental knee arthroplasty (UKA). In addition, the factors affecting the survival of the procedure were analyzed and the survival curve was compared according to the affecting factors. Materials and Methods: Ninety-nine cases of UKA performed between December 1982 and January 1996 were involved: 10 cases with Modular II, 44 cases with Microloc, and 45 cases with Allegretto prostheses. The mean follow-up period was 16.5 years. Clinically, the hospital for special surgery (HSS) scoring system and the range of motion (ROM) were evaluated. Radiographically, the femorotibial angle (FTA) was measured. The survival rate was analyzed using the Kaplan-Meier method. Cox regression analysis was used to identify the factors affecting the survival according to age, sex, body mass index, preoperative diagnosis, and type of implant. The Kaplan-Meier survival curves were compared according to the factors affecting the survival of UKA. Results: The overall average HSS score and ROM was 57.7 and 134.3° preoperatively, 92.7 and 138.4° at 1 year postoperatively, and 79.1 and 138.4° at the last follow-up (p<0.001, respectively). The overall average FTA was varus 0.8° preoperatively, valgus 4.1° at postoperative 2 weeks, and valgus 3.0° at the last follow-up. The overall 5-, 10-, 15- and 20-year survival rates were 91.8%, 82.9%, 71.0%, and 67.0%, respectively. The factors affecting the survival were the age and type of implant. The risk of the failure decreased with age (hazard ratio=0.933). The Microloc group was more hazardous than the other prostheses (hazard ratio=0.202, 0.430, respectively). The survival curve in the patients below 60 years of age was significantly lower than those of the patients over 60 years of age (p=0.003); the survival curve of the Microloc group was lower compared to the Modular II and Allegretto groups (p=0.025). Conclusion: The long-term clinical and radiographic results and survival of UKA using old fixed bearing prostheses were satisfactory. The selection of appropriate patient and prosthesis will be important for the long term survival of the UKA procedure.

Development of High-Resolution Fog Detection Algorithm for Daytime by Fusing GK2A/AMI and GK2B/GOCI-II Data (GK2A/AMI와 GK2B/GOCI-II 자료를 융합 활용한 주간 고해상도 안개 탐지 알고리즘 개발)

  • Ha-Yeong Yu;Myoung-Seok Suh
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_3
    • /
    • pp.1779-1790
    • /
    • 2023
  • Satellite-based fog detection algorithms are being developed to detect fog in real-time over a wide area, with a focus on the Korean Peninsula (KorPen). The GEO-KOMPSAT-2A/Advanced Meteorological Imager (GK2A/AMI, GK2A) satellite offers an excellent temporal resolution (10 min) and a spatial resolution (500 m), while GEO-KOMPSAT-2B/Geostationary Ocean Color Imager-II (GK2B/GOCI-II, GK2B) provides an excellent spatial resolution (250 m) but poor temporal resolution (1 h) with only visible channels. To enhance the fog detection level (10 min, 250 m), we developed a fused GK2AB fog detection algorithm (FDA) of GK2A and GK2B. The GK2AB FDA comprises three main steps. First, the Korea Meteorological Satellite Center's GK2A daytime fog detection algorithm is utilized to detect fog, considering various optical and physical characteristics. In the second step, GK2B data is extrapolated to 10-min intervals by matching GK2A pixels based on the closest time and location when GK2B observes the KorPen. For reflectance, GK2B normalized visible (NVIS) is corrected using GK2A NVIS of the same time, considering the difference in wavelength range and observation geometry. GK2B NVIS is extrapolated at 10-min intervals using the 10-min changes in GK2A NVIS. In the final step, the extrapolated GK2B NVIS, solar zenith angle, and outputs of GK2A FDA are utilized as input data for machine learning (decision tree) to develop the GK2AB FDA, which detects fog at a resolution of 250 m and a 10-min interval based on geographical locations. Six and four cases were used for the training and validation of GK2AB FDA, respectively. Quantitative verification of GK2AB FDA utilized ground observation data on visibility, wind speed, and relative humidity. Compared to GK2A FDA, GK2AB FDA exhibited a fourfold increase in spatial resolution, resulting in more detailed discrimination between fog and non-fog pixels. In general, irrespective of the validation method, the probability of detection (POD) and the Hanssen-Kuiper Skill score (KSS) are high or similar, indicating that it better detects previously undetected fog pixels. However, GK2AB FDA, compared to GK2A FDA, tends to over-detect fog with a higher false alarm ratio and bias.

Accuracy of HF radar-derived surface current data in the coastal waters off the Keum River estuary (금강하구 연안역에서 HF radar로 측정한 유속의 정확도)

  • Lee, S.H.;Moon, H.B.;Baek, H.Y.;Kim, C.S.;Son, Y.T.;Kwon, H.K.;Choi, B.J.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.1
    • /
    • pp.42-55
    • /
    • 2008
  • To evaluate the accuracy of currents measured by HF radar in the coastal sea off Keum River estuary, we compared the facing radial vectors of two HF radars, and HF radar-derived currents with in-situ measurement currents. Principal component analysis was used to extract regression line and RMS deviation in the comparison. When two facing radar's radial vectors at the mid-point of baseline are compared, RMS deviation is 4.4 cm/s in winter and 5.4 cm/s in summer. When GDOP(Geometric Dilution of Precision) effect is corrected from the RMS deviations that is analyzed from the comparison between HF radar-derived and current-metermeasured currents, the error of velocity combined by HF radar-derived current is less than 5.1 cm/s in the stations having moderate GDOP values. These two results obtained from different method suggest that the lower limit of HF radar-derived current's accuracy is 5.4 cm/s in our study area. As mentioned in previous researches, RMS deviations become large in the stations located near the islands and increase as a function of mean distance from the radar site due to decrease of signal-to-noise level and the intersect angle of radial vectors. We found that an uncertain error bound of HF radar-derived current can be produced from the separation process of RMS deviations using GDOP value if GDOP value for each component is very close and RMS deviations obtained from current component comparison are also close. When the current measured in the stations having moderate GDOP values is separated into tidal and subtidal current, characteristics of tidal current ellipses analyzed from HF radar-derived current show a good agreement with those from current-meter-measured current, and time variation of subtidal current showed a response reflecting physical process driven by wind and density field.

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.