• Title/Summary/Keyword: Angle Measurement

Search Result 2,170, Processing Time 0.037 seconds

The Diagnostic Usefulness of Stress Radiography in Chronic Lateral Ankle Instability (만성 발목 관절 외측 불안정성의 진단에서 스트레스 방사선검사의 유용성)

  • Kim, Yong-Min;Cho, Byung-Ki;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Park, Kyoung-Jin;Kim, Dong-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • Purpose: This study was performed to evaluate the diagnostic usefulness of ankle stress radiograph for evaluation of chronic lateral ankle instability. Materials and Methods: Among patients undergoing the modified-Brostrom procedure, 42 cases with complete rupture of the anterior talofibular ligament were enrolled in this study. Sixty Korean adults (120 cases) were recruited as the control group. Radiologic measurement of talar tilt and anterior talar translation was performed through stress radiographs using Telos device. We obtained the normal range of Korean adults, and used as a standard value for judgment of mechanical instability. We analyzed the sensitivity, specificity, positive and negative prediction value of ankle stress radiograph. Results: On ankle stress radiograph, normal range of talar tilt angle and anterior talar translation was below $8.3^{\circ}$, below 7.6mm. Talar tilt angle on varus stress radiograph showed 57% of sensitivity, 97% of specificity, 89% of positive and 86% of negative prediction value. Anterior talar translation on anterior drawer stress radiograph showed 69% of sensitivity, 97% of specificity, 91% of positive and 90% of negative prediction value. Conclusion: Ankle stress radiograph had a good specificity, positive and negative prediction value for the evaluation of mechanical instability. However it underestimated the mechanical instability of ankle joint. It must be remembered that normal stress radiograph does not exclude ankle instability.

  • PDF

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Uncertainties of SO2 Vertical Column Density Retrieval from Ground-based Hyper-spectral UV Sensor Based on Direct Sun Measurement Geometry (지상관측 기반 태양 직달광 관측장비의 초분광 자외센서로부터 이산화황 연직칼럼농도의 불확실성 분석 연구)

  • Kang, Hyeongwoo;Park, Junsung;Yang, Jiwon;Choi, Wonei;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.289-298
    • /
    • 2019
  • In this present study, the effects of Signal to Noise Ratio (SNR), Full Width Half Maximum (FWHM), Aerosol Optical Depth (AOD), $O_3$ Vertical Column Density ($O_3$ VCD), and Solar Zenith Angle (SZA) on the accuracy of sulfur dioxide Vertical Column Density ($SO_2$ VCD) retrieval have been quantified using the Differential Optical Absorption Spectroscopy (DOAS) method with the ground-based direct-sun synthetic radiances. The synthetic radiances produced based on the Beer-Lambert-Bouguer law without consideration of the diffuse effect. In the SNR condition of 650 (1300) with FWHM = 0.6 nm, AOD = 0.2, $O_3$ VCD = 300 DU, and $SZA=30^{\circ}$, the Absolute Percentage Difference (APD) between the true $SO_2$ VCD values and those retrieved ranges from 80% (28%) to 16% (5%) for the $SO_2$ VCD of $8.1{\times}10^{15}$ and $2.7{\times}10^{16}molecules\;cm^{-2}$, respectively. For an FWHM of 0.2 nm (1.0 nm) with the $SO_2$ VCD values equal to or greater than $2.7{\times}10^{16}molecules\;cm^{-2}$, the APD ranges from 6.4% (29%) to 6.2% (10%). Additionally, when FWHM, SZA, AOD, and $O_3$ VCD values increase, APDs tend to be large. On the other hand, SNR values increase, APDs are found to decrease. Eventually, it is revealed that the effects of FWHM and SZA on $SO_2$ VCD retrieval accuracy are larger than those of $O_3$ VCD and AOD. The SZA effects on the reduction of $SO_2$ VCD retrieval accuracy is found to be dominant over the that of FWHM for the condition of $SO_2$ VCD larger than $2.7{\times}10^{16}molecules\;cm^{-2}$.

Analysis of the GPS-derived Control Point Errors for Quality Assurance of 3D Digital Maps (3차원 수치지도 정확도 검증을 위한 GPS 기반 기준점 오차의 영향 분석)

  • Bae, Tae-Suk;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.153-160
    • /
    • 2010
  • It is necessary to determine accurate 3-dimensional coordinates of the building corner points that could be control or check points in order to verify the accuracy of 3D digital maps in the near future. The usual process of obtaining the coordinates of the building corner points is to set up the ground control points with a GPS and then to practice terrestrial survey such as distance or angle measurements. However, since an error in the ground control points can be propagated through the terrestrial survey into the final coordinates of the buildings, accurately should be considered as much as possible. The actual effect of the GPS-derived ground control point error on the estimates of the unknowns through the terrestrial survey is mathematically analyzed, and the simulation data is tested numerically. The error of the ground control points is tested in the cases of 1-4 cm for the horizontal components and 2-8 cm for the vertical component. The vertical component error is assigned twice the horizontal ones because of the characteristics of the GPS survey. The distance measurement is assumed for convenience and the precision of the estimated coordinates of the building corner points is almost linearly increased according to the errors of the ground control points. In addition, the final estimates themselves can vary by the simulated random errors depending on the precision of the survey instrument, but the precision of the estimates is almost independent of survey accuracy.

Kinematics and Grip Forces of Professionals, Amateurs and Novices during Golf Putting (퍼팅 시 프로와 아마추어, 초보 골퍼사이의 운동학적 변인과 그립 악력 비교)

  • Choi, Jin-Seung;Kim, Hyung-Sik;Kang, Dong-Won;Kim, Han-Su;Oh, Ho-Sang;Seo, Jeong-Woo;Yi, Jeong-Han;Lim, Young-Tae;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.405-410
    • /
    • 2011
  • The purpose of this study was to compare the differences in kinematic variables and grip forces among professionals(PG), amateurs(AG), and novice group(NG) during golf putting. The participants consisted of 3 groups based on their playing ability: 8 professional golfers (handicap<5), 8 amateurs (handicap<18) and 8 novice. Each subject attempted 2.1m putts from the hole. 3D motion analysis system(Motion analysis Corp., USA) with 6 high speed cameras and grip force measurement system(Kim et al., 2007) were used to acquired kinematic and force data, respectively. To compare differences among groups, joint angles of upper limbs, trajectory and smoothness by jerk cost function(JC) of putter head and grip forces were used in this study. Results showed that there were significant differences among groups in most of variables such as joint angles, trajectory & smoothness of putter head, and distribution of grip force in both hands. In brief, we confirmed that putting stroke in PG was more accurate and smooth than that in other groups, especially NG, due to their well-controlled upper limbs and keeping grip forces constant in both hands. It can be concluded that due to skilled levels, fundamental differences of putting movement could be identified and these differences might be helpful for improving one's putting skills.

Controlling the Work Functions of Graphene by Functionalizing the Surface of $SiO_2$ Substrates with Self-assembled Monolayers

  • Jo, Ju-Mi;Kim, Yu-Seok;Cha, Myeong-Jun;Lee, Su-Il;Jeong, Sang-Hui;Song, U-Seok;Kim, Seong-Hwan;Jeon, Seung-Han;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.400-401
    • /
    • 2012
  • 그래핀(Graphene)은 열 전도도가 높고 전자 이동도(200 000 cm2V-1s-1)가 우수한 전기적 특성을 가지고 있어 전계 효과 트랜지스터(Field effect transistor; FET), 유기 전자 소자(Organic electronic device)와 광전자 소자(Optoelectronic device) 같은 반도체 소자에 응용 가능하다. 그러나 에너지 밴드 갭이 없기 때문에 소자의 전기적 특성이 제한되는 단점이 있다. 최근에는 아크 방출(Arc discharge method), 화학적 기상 증착법(Chemical vapor deposition; CVD), 이온-조사법(Ion-irradiation) 등을 이용한 이종원자(Hetero atom)도핑과 화학적 처리를 이용한 기능화(Functionalization) 등의 방법으로 그래핀을 도핑 후 에너지 밴드 갭을 형성시키는 연구 결과들이 보고된 바 있다. 그러나 이러한 방법들은 표면이 균일하지 않고, 그래핀에 많은 결함들이 발생한다는 단점이 있다. 이러한 단점을 극복하기 위해 자가조립 단층막(Self-assembled monolayers; SAMs)을 이용하여 이산화규소(Silicon oxide; SiO2) 기판을 기능화한 후 그 위에 그래핀을 전사하면 그래핀의 일함수를 쉽게 조절하여 소자의 전기적 특성을 최적화할 수 있다. SAMs는 그래핀과 SiO2 사이에 부착된 매우 얇고 안정적인 층으로 사용된 물질의 특성에 따라 운반자 농도나 도핑 유형, 디락 점(Dirac point)으로부터의 페르미 에너지 준위(Fermi energy level)를 조절할 수 있다[1-3]. 본 연구에서는 SAMs한 기판을 이용하여 그래핀의 도핑 효과를 확인하였다. CVD를 이용하여 균일한 그래핀을 합성하였고, 기판을 3-Aminopropyltriethoxysilane (APTES)와 Borane-Ammonia(Borazane)을 이용하여 각각 아민 기(Amine group; -NH2)와 보론 나이트라이드(Boron Nitride; BN)로 기능화한 후, 그 위에 합성한 그래핀을 전사하였다. 기판 위에 NH2와 BN이 SAMs 형태로 존재하는 것을 접촉각 측정(Contact angle measurement)을 통해 확인하였고, 그 결과 NH2와 BN에 의해 그래핀에 도핑 효과가 나타난 것을 라만 분광법(Raman spectroscopy)과 X-선 광전자 분광법(X-ray photoelectron spectroscopy: XPS)을 이용하여 확인하였다. 본 연구 결과는 안정적이면서 패턴이 가능하기 때문에 그래핀을 기반으로 하는 반도체 소자에 적용 가능할 것이라 예상된다.

  • PDF

Design of Optical System for LED Lamp using MR16 (MR16용 LED 램프 조명설계)

  • Kim, Jun-Hyun;Moon, Byung-Kwon;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4725-4732
    • /
    • 2012
  • This paper studies MR16 that can strengthen the strength and make up for the weakness of MR16 by replacing halogen light source using multifaceted Reflector(MR16) with LED light source. To achieve this, developed MR16 for LED applying optical system that four aspheric lens is one sheet. Optical system is designed by optics software and lighting performance of the designed data is predicted lighting simulation program. Also, heatsink's heat radiation analysis program to predict the thermal performance. Finally, optical prototype system based on simulation analysis data is manufactured and the results comparing performance of the developed system and the designed data are follows: Radiation angle was around $50^{\circ}{\sim}60^{\circ}$ in results of simulation analysis and the test of the prototype system. Also, temperature measurement result indicates that the thermal equilibrium is realized after one minute and thirty seconds and heat is generated up $60^{\circ}C$ in all of simulation analysis and the test of the prototype system. Finally, simulation analysis result on light disturbance curve of MR16 is similar to that of performance of the prototype system.

A 2D / 3D Map Modeling of Indoor Environment (실내환경에서의 2 차원/ 3 차원 Map Modeling 제작기법)

  • Jo, Sang-Woo;Park, Jin-Woo;Kwon, Yong-Moo;Ahn, Sang-Chul
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.355-361
    • /
    • 2006
  • In large scale environments like airport, museum, large warehouse and department store, autonomous mobile robots will play an important role in security and surveillance tasks. Robotic security guards will give the surveyed information of large scale environments and communicate with human operator with that kind of data such as if there is an object or not and a window is open. Both for visualization of information and as human machine interface for remote control, a 3D model can give much more useful information than the typical 2D maps used in many robotic applications today. It is easier to understandable and makes user feel like being in a location of robot so that user could interact with robot more naturally in a remote circumstance and see structures such as windows and doors that cannot be seen in a 2D model. In this paper we present our simple and easy to use method to obtain a 3D textured model. For expression of reality, we need to integrate the 3D models and real scenes. Most of other cases of 3D modeling method consist of two data acquisition devices. One for getting a 3D model and another for obtaining realistic textures. In this case, the former device would be 2D laser range-finder and the latter device would be common camera. Our algorithm consists of building a measurement-based 2D metric map which is acquired by laser range-finder, texture acquisition/stitching and texture-mapping to corresponding 3D model. The algorithm is implemented with laser sensor for obtaining 2D/3D metric map and two cameras for gathering texture. Our geometric 3D model consists of planes that model the floor and walls. The geometry of the planes is extracted from the 2D metric map data. Textures for the floor and walls are generated from the images captured by two 1394 cameras which have wide Field of View angle. Image stitching and image cutting process is used to generate textured images for corresponding with a 3D model. The algorithm is applied to 2 cases which are corridor and space that has the four wall like room of building. The generated 3D map model of indoor environment is shown with VRML format and can be viewed in a web browser with a VRML plug-in. The proposed algorithm can be applied to 3D model-based remote surveillance system through WWW.

  • PDF