• 제목/요약/키워드: Angle Measurement

검색결과 2,155건 처리시간 0.024초

오픈소스하드웨어를 이용한 침상머리각도 측정 시스템의 래피드 프로토타이핑 (Rapid Prototyping of Head-of-Bed Angle Measurement System using Open-Source Hardware)

  • 조봉언;박영상;서숙길;김진걸;이영삼
    • 제어로봇시스템학회논문지
    • /
    • 제21권11호
    • /
    • pp.1038-1043
    • /
    • 2015
  • When the study on the relationship between the Head-of-Bed (HOB) angle and ventilator-associated pneumonia is performed, the fact that the HOB angle can only be measured intermittently imposes a significant limitation on the study. Therefore, there has been demand for the development of a device that can measure the HOB angle continuously. In this paper, we propose the rapid prototyping of an HOB measurement system using open-source hardware and software. The proposed system helps to maintain the HOB angle at a particular angle by displaying the angle and helps the medical study of pneumonia patients by enabling continuous data acquisition. Firstly, we eliminate the process of making an MCU board by utilizing an open-source hardware mbed LPC1768. Secondly, we reduce the software development time by using libraries and hence enabling the easy use of peripherals. Thirdly, for rapid prototyping, we build the enclosure of the proposed system using a 3D printer. The proposed system can be attached and detached to and from a bed. Therefore, we can attach it to the bed of a patient for whom measurement of the HOB angle is necessary. Finally, we check the measurement performance and the validity of the proposed system through an experiment utilizing an incremental encoder.

하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토 (Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool)

  • 임지영;임현승;박대성;이재헌;이나경
    • 재활복지공학회논문지
    • /
    • 제10권1호
    • /
    • pp.37-45
    • /
    • 2016
  • 이 연구의 목적은 래스터입체사진술이 적용된 ABW-mapper를 사용하여 얻은 관상면 상에서의 하지 정렬 측정에 대하여 측정자 내, 측정자 간, 측정-재측정 간 각각의 신뢰도와 타당도를 조사하고 평가하는 것이다. 열여덟 명의 대상자가 이 연구에 참여하였다. 일주일간격으로 두 번의 세션에 걸쳐서 두 사람의 측정자가 각각 ABW-mapper를 사용하여 기립자세에서의 S각(입체사진 각-래스터입체사진 촬영을 통해 측정한 관상면상의 하지 정렬 측정 각)을 측정하였고, 첫 번째 세션에서는 짧은 시간 간격으로 한 측정자가 같은 대상자에 대하여 두 번씩 측정하였다. Q각은 디지털카메라로 기립자세를 촬영한 사진에서 고니어미터로 측정하였다. HKA각은 컴퓨터 기반 디지털 방사선 영상사진 위에서 측정 소프트웨어를 사용하여 측정하였다. 급내상관계수(ICC)를 통해 신뢰도를 분석하였고, 피어슨 상관계수를 사용하여 타당도를 검사하였다. 그 결과, S각 측정은 매우 높은 측정자 내 (ICC=0.956~0.974), 측정자 간 (ICC=0.962) 검사-재검사 간 (ICC=0.945) 신뢰도를 나타냈으며, S각과 Q각, S각과 HKA각 사이에는 강한 음의 상관관계(각각 r=-0.739, -0.702)를 나타냈다. 따라서, ABW-mapper에 의한 래스터입체사진법을 통한 S각 측정은 관상면에서의 하지정렬의 측정에 대하여 Q각이나 HKA각 측정에 관련하여 예비적 또는 보완적 도구로 사용될 수 있을 것이라 생각된다.

고전압 전기용량 브리지를 이용한 전압변성기의 비오차와 위상각 오차의 측정과 불확도 분석 (Measurement of Ratio Error/Phase Angle Error of Potential Transformer using High Voltage Capacitance Bridge and Uncertainty Analysis)

  • 권성원;이상화;김명수;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권3호
    • /
    • pp.134-141
    • /
    • 2006
  • A potential transformer(PT) has ratio error and phase angle error. Precise measurement of the errors of PT can be achieved using high voltage capacitance bridge, high voltage capacitor and low voltage capacitor. The uncertainty for this method is evaluated and found to be $20{\times}10^{-6}$ in both ratio error and phase angle error. The values measured for PT using the method are well consistent with the those measured for same PT in NMIA(National Measurement Institute of Australia) within the corresponding uncertainty.

전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment)

  • 정재갑;박영태;권성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권9호
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

측정방법에 따른 흡기포트 분사식 다공 가솔린인젝터의 분무각 비교 (Comparison of Spray Angles of Multihole Port Fuel Gasoline Injector with Different Measuring Methods)

  • 김재호;임정현;노수영;문병수
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.17-26
    • /
    • 2000
  • The main parameter commonly used to evaluate spray distribution is spray angle. Spray angle is important because it influences the axial and radial distribution of the fuel. Spray angles were measured and compared for the two non-air assisted injectors such as 2hole-2stream 4hole-1stream injectors used for port fuel injection gasoline engines with n-heptane as a fuel by three different measuring techniques, i.e., digital image processing, shadowgraphy, and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35 MPa into the room temperature and atmospheric pressure environment. In digital image processing approach, the selection of the transmittance level is critical to obtain the edge of spray and hence to measure the spray angle. From the measurement results by the shadowgraphy technique, it is dear that the spray angle is varied during the spray injection period. The measurement results from spray patternator show that the different spray angles exist in different region. Spray angle increases with the increase in the injection pressure. it is suggested that the spray angle and stream separated angle should be specified when spray is characterized for 2hole-2stream injector, because spray angle is much different though stream separated angle is same. It was also considerably affected by the measurement techniques introduced in this experimental work. However, the optimal axial distance for measuring the spray angle seems to be at least 60-80 mm from the injector tip for two non-air assisted injectors.

  • PDF

에어셀을 이용한 손목 재활훈련 장치 (Wrist Rehabilitation Training Device Using Pneumatic Inflation and Deflation of Air Cells)

  • 이영진;정유진;구교인;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권2호
    • /
    • pp.37-42
    • /
    • 2015
  • In this paper, we propose a wrist rehabilitation training device using pneumatic inflation and deflation of air cells. By alternating inflation and deflation of upper and lower air cells, the device makes the flexional and extensional movement for wrist rehabilitation. With the angular displacement sensor, it measures the flexion-extension angle of the wrist during the training and the bending angle is used for the automatic control of the device. Using the sensor output, the regression equation was obtained to measure the bending angle of the wrist from a wrist rehabilitation training device. The measurement error of the device was evaluated by comparing the measurement output with the angle from the photograph. The measurement error of wrist bending angle between the sensor and photo was $3.2^{\circ}$ in average. With additional test and improvement, the pneumatic wrist rehabilitation training device might be used for rehabilitation training.

7공 프로브의 원추각이 유동 측정 정확도에 미치는 영향에 대한 연구 (Effect of Cone Angle of a Seven-Hole Probe on the Accuracy Flow Measurement)

  • 이용진;박정신;노영철;전창수;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.5-11
    • /
    • 2011
  • In this study, the effect of cone angle of seven-hole probe on the accuracy of measured flow angle and velocity has been investigated. The seven-hole probe consisted of seven 1mm OD stainless inner tubes and one 3mm ID stainless tube. Six cone angles of $45^{\circ}$, $60^{\circ}$, $75^{\circ}$, $90^{\circ}$, $105^{\circ}$ and $120^{\circ}$ were tested. Calibrations of the seven-hole probes were conducted within ${\pm}60^{\circ}$ range with the interval of $5^{\circ}$. Analysis results show that the effect on the cone angle was not significant on the accuracy of the measured flow angle, pressure, and velocity. However, the data reduction method had more effect on the measurement accuracy.

5면 Photodiode를 이용한 양산 공정용 LED 지향각 측정 시스템개발에 관한 연구 (Development and Mass Production Potential of a Novel 5-side Photodiode LED Viewing Angle Measurement System)

  • 김대완;박찬희;김근식;김철생
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.623-631
    • /
    • 2011
  • Light emitting diodes (LEDs) which can produce uniform luminescence need a very difficult and complex procedure because LEDs have strong and straight optical property. One of the major parameters for LED production is the determination of the viewing angle. However, in the present, there is still no available production technology to measure LED viewing angle and optical property. In this study, we developed a five-side LED viewing angle and optical property measurement system, having a source meter that uses a high speed switching photo relay instead of a mercury relay. This new measurement system can measure the viewing angle at a very high accuracy of ${\pm}0.66^{\circ}$. This new technology presents a great potential for fast and reliable LED mass production, which can significantly cut down the cost from savings in production time.

근골격계 부하 평가를 위한 2차원 자세 측정 시스템 개발 (Development of a 2D Posture Measurement System to Evaluate Musculoskeletal Workload)

  • 박성준;박재규;최재호
    • 대한인간공학회지
    • /
    • 제24권3호
    • /
    • pp.43-52
    • /
    • 2005
  • A two-dimensional posture measurement system was developed to evaluate the risks of work-related musculoskeletal disorders(MSDs) easily on various conditions of work. The posture measurement system is an essential tool to analyze the workload for preventing work-related musculoskeletal disorders. Although several posture measurement systems have been developed for workload assessment, some restrictions in industry still exist because of its difficulty on measuring work postures. In this study, an image recognition algorithm was developed based on a neural network method to measure work posture. Each joint angle of human body was automatically measured from the recognized images through the algorithm, and the measurement system makes it possible to evaluate the risks of work-related musculoskeletal disorders easily on various working conditions. The validation test on upper body postures was carried out to examine the accuracy of the measured joint angle data from the system, and the results showed good measuring performance for each joint angle. The differences between the joint angles measured directly and the angles measured by posture measurement software were not statistically significant. It is expected that the result help to properly estimate physical workload and can be used as a postural analysis system to evaluate the risk of work-related musculoskeletal disorders in industry.

레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발 (Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter)

  • 배기윤;이정인
    • 터널과지하공간
    • /
    • 제12권4호
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.