• 제목/요약/키워드: Angle Measurement

검색결과 2,155건 처리시간 0.031초

Novel Technology for View Angle Performance Measurement

  • Rykowski, Ronald;Lee, Jong-Seo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1358-1361
    • /
    • 2008
  • Several different techniques currently exist for measuring display view angle performance. These include conoscopes, goniometric systems, and, most recently introduced to the market, instruments based on Imaging Sphere technology. This paper will compare measurement accuracy and speed of these various methodologies with different FPD types and even 3-D displays.

  • PDF

Definition and Correlation for Spray Angle in Non-Reacting Diesel Fuel Sprays

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.244-250
    • /
    • 2006
  • Of the macroscopic spray characteristics of non-reacting diesel fuel sprays, the spray angle reflects directly the atomization and air entrainment processes downstream the nozzle. In addition, spray angle is important because it will be closely related to the spray penetration. The existing definitions for the measurement of spray angle as well as the correlations for the prediction of spray angle are, therefore, summarized and reviewed. The existing definition of spray angle can be classified into four groups: distance based on orifice diameter, distance based on spray tip penetration, definition based on surface wave, and definition based on atomization. It is strongly required to specify the definition and measurement method when the data for spray angle is reported. The existing correlations for spray angle can be classified into two groups: theoretical and empirical correlations. The study on the evaluation of the existing correlations fer spray angle is required.

  • PDF

휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘 (Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System)

  • 선은혜;김동연;김용태
    • 한국지능시스템학회논문지
    • /
    • 제26권4호
    • /
    • pp.321-326
    • /
    • 2016
  • 본 논문에서는 휴대용 휘도측정시스템의 측정위치기반 휘도보정알고리즘을 제안한다. 측정거리와 측정각도에 따라 휘도 값은 변화하며, 측정거리와 측정각도를 고려한 알고리즘을 적용하여 기존에 개발된 영상기반 휘도측정시스템의 오차를 개선한다. 카메라 영상기반의 휘도 정보를 정확하게 획득하는 면측정방법을 제안하기 위해서 점휘도계로 측정대상물과의 측정각도에 따른 휘도 값의 변화를 측정한다. 측정거리, 측정각도와 휘도 값 간의 연관성을 수식으로 나타내었고, 측정위치를 고려한 알고리즘을 제안한다. 실험용 간판을 대상으로 점휘도계와 제안한 휘도측정시스템을 비교 평가 실험하고 제안한 휘도측정시스템의 성능을 검증하였다.

전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden)

  • 정재갑;김한준;권성원;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

손실각 표준기 전극의 진직, 진원도 측정시스템 개발 (Development of Straightness, Roundness Measurement System for Standard Electrode of Loss Angle)

  • 장종훈
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.198-203
    • /
    • 1998
  • To acquire the high precision of profile for standard electrode of loss angle, it is needed ultraprecision machining technology like MEAP(Magnetic Electronic Abrasive Polishing) and the very high profile measurement technology which can measure a micro unit about the workpiece. So, in this paper, it was developed the measurement system of precision of profile using non-contactable sensor that was approximate sensor of capacitance type, because that is better than others in the electrical characteristics. And standard electrode of loss angle was machined by the MEAP machining technology. In this study, it was development of precision measurement system. This system could be used measure the workpiece of roundness and straightness much more precise and faster than general mechanical measurement system done before. And it could be helped to minimize machining time and planning by very fast and precise measurement about the workpiece.

  • PDF

발의 형태 분석을 위한 군집분석(II) -19~24세 남자대학생을 중심으로- (Cluster Analysis for Foot Type (II) -The subject of the college men between the age of 19~24 years-)

  • 문명옥
    • 한국의류학회지
    • /
    • 제18권5호
    • /
    • pp.637-645
    • /
    • 1994
  • The purpose of this study was to analyze the characteristics of men's foot and the foot type by cluster analysis for men's footwear. The sample size for the study was 200 college men between age 19 and 24 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows: 1. The size of If items of men's foot is larger than women's foot. 2. There were 9 items selected by factor analysis. 3. The cluster analysis of the direct measurement: Cluster 1: The items of the direct measurement is all much the same to mean value of this age group. Cluster 2: The foot size is relatively small to other clusters. Cluster 3: The foot size is relatively large to other clusters. 4. The cluster analysis of indirect measurement: Cluster 1: The foot print angle is the most value and Metatarso-Phalanx angle is nomral Cluster 2: The foot print angle is middle and Metatarso-Phalanx angle is normal. Cluster 3: The foot print angle is high and Metatarso-Phalanx angle is the smallest. Cluster 4: The foot print angle is low and Metatarso-Phalanx angle is all the much same to mean value of this age group.

  • PDF

발의 형태 분석을 위한 군집분석(I) - 19~23세 여자 대학생을 중심으로 - (Cluster Analysis for Foot Type(I) - The subject of the college women between the age of 19~23 years -)

  • 문명옥
    • 한국의류학회지
    • /
    • 제18권2호
    • /
    • pp.211-220
    • /
    • 1994
  • The purpose of this study was to analyze the foot type by cluster analysis for footwear. The sample size for the study was 200 college womens between age 19 and 23 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows : 1. 1'here were 9 items selected by factor analysis. 2.'rho cluster analysis of the foot must be analyzed by direct and indirect measurement indivisually. 3. The cluster analysis of the direct measurement ; Cluster 1 : 1'he foot length is all much the same to mean value of this age group and the items of width and circumference are relatively small to other clusters. Cluster 2 ; The foot length is relatively small to other clusters and the items of width and circumference are all much the same to mean value of this age group. Cluster 3 ; The foot sine Is relatively large to other clusters. 4. The cluster analysis of indirect measurement ; Cluster 1 ; The (cot print angle is high find Metatarso-Phalanx angle is transformed Cluster 2 ; The foot print angle is low and Melatarso-Phalanx angle is normal. Cluster 3 : Tho foot print angle Is middle and Metatarso-Phalanx angle is all the mush same to mean value of this age group. Cluster 4 . The foot print angle Is the most value and Metatarso-Phalanx angle is normal.

  • PDF

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

미소 액적의 접촉각 및 건조 특성 측정 시스템 개발 (Development of Measurement System for Contact Angle and Evaporation Characteristics of a Micro-droplet on a Substrate)

  • 권계시;안승현;장민혁
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.414-420
    • /
    • 2013
  • We developed inkjet based measurement system for micro-droplet behavior on a substrate. By using the inkjet dispenser, a droplet, which is as small as few pico-liter in volume, can be jetted and the amount can be controlled. After jetting, the droplet image on the substrate is acquired from side view camera. Then, droplet profile is extracted to measure droplet volume, contact angle and evaporation characteristics. Also top view image of the droplet is acquired for better understanding of droplet shape. The previous contact angle measurement method has limitations since it mainly measures the ratio of height and contact diameter of droplet on a substrate. Unlike previous measurement system, our proposed method has advantages because various behavior of droplet on substrate can be effectively analyzed by extracting the droplet profile.