• 제목/요약/키워드: Angle Beam Method

검색결과 465건 처리시간 0.035초

나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구 (Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization)

  • 신경인;안선훈;김성훈
    • 한국의류학회지
    • /
    • 제27권5호
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

이온빔 배향을 이용한 수직 폴리이미드 표면에서의 틸트 각 제어 (Control of Tilt Angle on Homeotropic Polyimide Surface by Ion Beam Alignment)

  • 강동훈;김병용;강상훈;황정연;한진우;김종환;강희진;옥철호;오용철;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.288-289
    • /
    • 2006
  • The tilt angle generation of nematic liquid crystal(NLC) on the homeotropic polyimide(PI) surface by the new Ion beam alignment method is studied. The tilt angle of NLC on the homeotropic PI surface for all incident angle is about 38and this has a stabilization trend. And the good LC alignment of the NLC on the PI surface by ion beam exposure of 45Incident angle was observed. Also the tilt angle of NLC on the homeotropic PI surface by ion beam exposure of 45Incident angle had a tendency to decrease as ion beam energy density increase. So we had known that pretilit angle could be controlled from verticality to horizontality.

  • PDF

Rapid assessment of suspension bridge deformation under concentrated live load considering main beam stiffness: An analytical method

  • Wen-ming Zhang;Jia-qi Chang;Xing-hang Shen;Xiao-fan Lu;Tian-cheng Liu
    • Structural Engineering and Mechanics
    • /
    • 제88권1호
    • /
    • pp.53-65
    • /
    • 2023
  • With the gradual implementation of long-span suspension bridges into high-speed railway operations, the main beam's bending stiffness contribution to the live load response permanently grows. Since another critical control parameter of railway suspension bridges is the beam-end rotation angle, it should not be ignored by treating the main beam deflection as the only deformation response. To this end, the current study refines the existing method of the main cable shape and simply supported beam bending moment analogy. The bending stiffness of the main beam is considered, and the main beam's analytical expressions of deflection and rotation angle in the whole span are obtained using the cable-beam deformation coordination relationship. Taking a railway suspension bridge as an example, the effectiveness and accuracy of the proposed analytical method are verified by the finite element method (FEM). Comparison of the results by FEM and the analytical method ignoring the main beam stiffness revealed that the bending stiffness of the main beam strongly contributed to the live load response. Under the same live load, as the main beam stiffness increases, the overall deformation of the structure decreases, and the reduction is particularly noticeable at locations with original larger deformations. When the main beam stiffness is increased to a certain extent, the stiffening effect is no longer pronounced.

Defects Length Measurement using an Estimation Algorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup;Kang, E-Sok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1452-1457
    • /
    • 2004
  • In this paper, a method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed to an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle to the image normal to the wall and thus, it enables the accurate measurement of the defect lengths only by using a single camera and a laser slit beam.

  • PDF

레이저 슬릿 빔의 경사각과 카메라 자세 추정 알고리듬을 이용한 벽면결함 길이측정 (Defects Length Measurement Using an Estimation Agorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam)

  • 김영환;윤지섭;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 2002
  • A method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation, which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed as an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle as the image normal as the wall and thus, it enables the accurate measurement of the defect lengths by using a single camera and a laser slit beam.

접촉각측정에 의한 표면의 특성연구 - I. 레이저광선 투영에 의한 접촉각의 측정방법- (Characterization of Surfaces by Contact Angle Goniometry - I. Contact Angle Measurement by Laser Beam Projection-)

  • 박정희
    • 한국의류학회지
    • /
    • 제15권1호
    • /
    • pp.70-75
    • /
    • 1991
  • 본 연구에서는 레이저광선의 투영을 이용한 접촉각측정기구가 개발되었다. 이 새로운 방법은 편평한 표면분만 아니라 직격이 가는 섬유를 포함한 굴곡진 표면에서는 stationary, advancing그리고 receding contact angle-을 신속하고 정확하게 측정할 수 있게 하여 준다. 가는 레이저광선이 액체와 고체사이 계면의 끝을 통과하여 tangent screen의 각도를 재는 눈금상에 중심으로부터 방사상으로 두개의 선이 나타나게 된다. 이때 눈금상에 투영된 두개의 레이저광선 사이의 각도를 접촉각으로 결정한다. 이 새로운 기구를 사용한 결과, PMMA(Perspex-CQ)상에서의 접촉각은 문헌상의 접촉각과 일치함으로써 간편하고 정확한 접촉각 측정법임을 입증할 수 있었다.

  • PDF

이온빔 조사 각도와 에너지강도에 의한 수직 배향막의 특성 분석 (Characteristic Analysis of Vertical Alignment by Ion-beam Irradiation Angle and Energy Density)

  • 강동훈;오병윤;김병용;한진우;김영환;옥철호;한정민;이상극;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.398-398
    • /
    • 2007
  • The Liquid Crystal (LC) alignment uniformity is very important in LC devices. The alignment mechanism of LC molecules on a rubbed polyimide (PI) surface is very important for both LC fundamental research and application. So, Generally a rubbing method to align LC has been widely used to mass-produce LCD panels. But because rubbing method is contact method between rubbing fabric and indium-tin-oxide glass or flexible substrate, rubbing method has some defects, such as the electrode charges and the creation of contaminating particles. Thus we strongly recommend a non-contact alignment technique for getting rid of some defects of rubbing method. Most recently, the LC aligning capabilities achieved by ion-beam exposure on the organic and nonorganic thin film surface have been reported successfully. In this research, we studied the tilt angle generation and electro-optical performances for a NLC on homeotropic polyimide surfaces with ion-beam exposure. The LC aligning capabilities of a nematic liquid crystal (NLC) on a homeotropic PI surface using a new ion-beam method were studied. On the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good. And we achieved satisfactory result for EO character.

  • PDF

초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석 (Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer)

  • 남영현
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

회전하는 보의 유한요소해석을 위한 유리형상함수의 확장 (Extension of Rational Interpolation Functions for FE Analysis of Rotating Beams)

  • 김용우;정재호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.573-578
    • /
    • 2009
  • Starting from the rotating beam finite element in which the interpolating shape functions satisfies the governing static homogeneous differential equation of Euler-Bernoulli rotating beams, we derived new shape functions that satisfies the governing differential equation which contains the terms of hub radius and setting angle. The shape functions are rational functions which depend on hub radius, setting angle, rotational speed and element position. Numerical results for uniform and tapered cantilever beams with and without hub radius and setting angle are compared with the available results. It is shown that the present element offers an accurate method for solving the free vibration problems of rotating beam.

  • PDF

레이저 슬릿빔의 경사각과 카메라 자세 추정 알고리즘을 이용한 벽면 결함 측정 (Measurement of Defects on the Wall by use of the Inclination Angle of Laser Slit Beam and Position Tracking Algorithm of Camera)

  • 김영환;송상호;윤지섭;강이석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.339-339
    • /
    • 2000
  • In this parer, a method of measuring the size of defects on the wall and restructing the defect image of 3-dimension is developed based on the tracking algorithm of a camera position which uses the inclination angle of line slit beam for overcoming the difficulty of the corresponding problem identifying the image point in the both image. In the experiments, an algorithm for estimating the horizontal angle of CCD camera is presented and validated by applying it to the measurement of area and length under the variations of both the distance and the angle of CCD camera. And its performance is compared to that of the rotating and mapping method of image which has the Euclidian distance.

  • PDF