• Title/Summary/Keyword: Angiography room

Search Result 50, Processing Time 0.033 seconds

Celiac Artery Compression After a Spine Fracture, and Pericardium Rupture After Blunt Trauma: A Case Report from a Single Injury

  • Kim, Joongsuck;Cho, Hyun Min;Kim, Sung Hwan;Jung, Seong Hoon;Sohn, Jeong Eun;Lee, Kwangmin
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.130-135
    • /
    • 2021
  • Celiac artery compression is a rare condition in which the celiac artery is compressed by the median arcuate ligament. Case reports of compression after trauma are hard to find. Blunt traumatic pericardium rupture is also a rare condition. We report a single patient who experienced both rare conditions from a single blunt injury. An 18-year-old woman was brought to the trauma center after a fatal motorcycle accident, in which she was a passenger. The driver was found dead. Her vital signs were stable, but she complained of mild abdominal pain, chest wall pain, and severe back pain. There were no definite neurologic deficits. Her initial computed tomography (CT) scan revealed multiple rib fractures, moderate lung contusions with hemothorax, moderate liver injury, and severe lumbar spine fracture and dislocation. She was brought to the angiography room to check for active bleeding in the liver, which was not apparent. However, the guide wire was not able to pass through the celiac trunk. A review of the initial CT revealed kinking of the celiac trunk, which was assumed to be due to altered anatomy of the median arcuate ligament caused by spine fractures. Immediate fixation of the vertebrae was performed. During recovery, her hemothorax remained loculated. Suspecting empyema, thoracotomy was performed at 3 weeks after admission, revealing organized hematoma without pus formation, as well as rupture of the pericardium, which was immediately sutured, and decortication was carried out. Five weeks after admission, she had recovered without complications and was discharged home.

Ruptured pseudoaneurysm of the internal maxillary artery in zygomaticomaxillary fracture: a case report

  • Lim, Soo Yeon;Lee, Hyun Gun;Kim, Kyu Nam;Kim, Hoon;Oh, Dong Hyun;Koh, In Chang
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.89-92
    • /
    • 2022
  • Post-traumatic pseudoaneurysms of internal maxillary artery are rare, but may be life-threatening. When arterial damage leads to pseudoaneurysm formation, delayed intractable epistaxis can occur. We report our experience with the diagnosis and management of a ruptured internal maxillary arterial pseudoaneurysm that was discovered preoperatively in a patient with a zygomaticomaxillary complex (ZMC) fracture. He presented to the emergency room with epistaxis, which ceased shortly, and sinus hemorrhage was observed with a fracture of the posterior maxillary wall. The patient was scheduled for open reduction and internal fixation (ORIF) of the ZMC fracture. However, immediately before surgery, uncontrolled epistaxis of unknown origin was observed. Angiography indicated a pseudoaneurysm of the posterior superior alveolar artery. Selective endovascular embolization was performed, and hemostasis was achieved. After radiologic intervention, ORIF was successfully implemented without complications. Our case shows that in patients with a posterior maxillary wall fracture, there is a risk of uncontrolled bleeding in the perioperative period that could be caused by pseudoaneurysms, which should be considered even in the absence of typical symptoms.

Evaluation of Zone 2 Thoracic Endovascular Aortic Repair Performed with and without Prophylactic Embolization of the Left Subclavian Artery in Patients with Traumatic Aortic Injury

  • Miju Bae;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Seon Uoo Choi;Seunghwan Song
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.577-583
    • /
    • 2021
  • Objective: To report the authors' experience in performing thoracic endovascular aortic repair (TEVAR) for zone 2 lesions after traumatic aortic injury (TAI). Materials and Methods: This retrospective review included 10 patients who underwent zone 2 TEVAR after identification of aortic isthmus injury by CT angiography (CTA) upon arrival at the emergency room of a regional trauma center from 2016 to 2019. Patients were classified into two groups: those who underwent left subclavian artery (LSA) embolization concurrently with the main TEVAR procedure, and those in whom LSA embolization was not performed during the main procedure, but was planned as a bailout treatment if type II endoleak was noted on follow-up CTA images. Pre-procedural and procedure-related factors and post-procedure prognosis were compared between the groups. Results: There were no differences in pre-procedural factors, occurrence of endoleaks, and post-procedure prognosis (including mortality) between patients in the two groups. The duration of the procedure was shorter in the non-LSA embolization group (61 minutes vs. 27 minutes, p = 0.012). During follow-up, type II endoleak did not occur in either group. Conclusion: Delaying preventative LSA embolization until stabilization of the patient would be desirable when performing zone 2 TEVAR for TAI, in the absence of endoleak on the completion aortography image taken after complete deployment of the stent graft.

Chest CT Parameters to Predict the Major Adverse Events in Acute Submassive Pulmonary Embolism (혈역학적으로 안정된 폐색전증 환자에서의 임상적 악화를 예측하는 전산화 단층촬영상 소견)

  • Jung, Sang-Ku;Kim, Won-Young;Lee, Choong-Wook;Seo, Dong-Woo;Lee, Youn-Sun;Lee, Jae-Ho;Oh, Bum-Jin;Kim, Won;Lim, Kyoung-Soo;Hong, Sang-Bum;Lim, Chae-Man;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • Background: The purpose of this study was to determine the prognostic significance of chest computed tomographic (CT) parameters in acute submassive pulmonary embolism (PE). Methods: Between January 2006 and December 2009, 268 consecutive patients with acute submassive PE that was confirmed by chest CT with pulmonary angiography in emergency room were studied. One experienced radiologist measured CT parameters and judged the presence of right ventricular dysfunction. CT parameters were analyzed to determine their ability to predict a major adverse event (MAE). Results: There were 220 patients included and 61 (27.7%) had MAE. Left ventricular and right ventricular maximum minor axis ($36.4{\pm}8.0$ vs. $41.7{\pm}7.4$, p<0.01; $45.7{\pm}9.4$ vs. $41.5{\pm}7.6$, p<0.01), superior vena cava diameter ($19.2{\pm}3.4$ vs. $18.0{\pm}3.4$, p=0.02), azygos vein diameter ($10.0{\pm}2.2$ vs. $9.2{\pm}2.3$, p=0.02), septal displacement (19 vs. 18, p<0.01) were significantly higher in MAE group than in no MAE group. Patients with MAE had high right ventricular/left ventricular dimension ratio (RV/LV ratio) compared to patients without MAE ($1.34{\pm}0.48$ vs. $1.03{\pm}0.28$, p<0.01). The most useful cut-off value of RV/LV ratio for MAE was 1.3 and the area under the curve was 0.71 (0.62~0.79). Conclusion: RV/LV ratio on chest CT was a significant predictor of submassive PE related shock, intubation, in-hospital mortality, thrombolysis, thrombectomy within 30 days.

Multiple External Carotid Artery Aneurysms with Neurofibromatosis - Case Report - (신경섬유종을 동반한 다발성 외경동맥 동맥류 - 증 례 보 고 -)

  • Pyo, Sae Yeong;Kim, Moo Seong;Sim, Hong Bo;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1248-1254
    • /
    • 2000
  • Multiple external carotid artery aneurysms with neurofibromatosis are rare. Trauma is the primary cause in the development of aneurysms of the external carotid artery. A 39-year-old female patient was referred to the emergency room because of a headache and a huge lump over the left temporo-parieto-occipital region. The physical examination revealed a huge round mass, $5{\times}15{\times}18cm$, in the left temporo-parieto-occipital region and low set left ear and multiple caf au lait spots in trunk and extremities. The external carotid artery angiography demonstrated multiple aneurysms arising from the superficial temporal artery and occipital artery. A MRI showed a huge hematoma on temporo-parieto-occipital region and postauricular mass suggested of subcutaneous neurofibroma. Embolization followed by surgical resections of those aneurysms and neighboring mass were performed and good result was obtained. We report our case with review of literature.

  • PDF

Off-Pump Coronary Artery Bypass Grafting (심폐바이패스없이 시행하는 관상동맥우회술)

  • Kim, Ki-Bong;Lim, Hong-Gook;Huh, Jae-Hak;Ahn, Hyuk;Ham, Byung-Moon
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.38-44
    • /
    • 2000
  • Background: We analyzed the result of the "Off-Pump" Coronary Artery Bypass grafting (OPCAB) performed to minimize inflammatory responses to cardiopulmonary bypass and myocardial ischemia during the aortic cross-clamp period. Material and Method : The preoperative diagnosis operative procedure mortality complication and postoperative course of the 50 patients who underwent OPCAB between January 1998 and September 1998 were analyzed. There were 34 males and 16 females with mean age of 60$\pm$9 years. Preoperative clinical diagnoses were unstable angina in 31(62%) stable angina in 16(32%) and clinical diagnoses were unstable angina in 31(62%) stable angina in 16(32%) and postinfarction angina in 3(6%) patients. Preoperative angiographic diagnoses were three-vessel disease in 25(50%) two-vessel disease in 5(10%) one-vessel disease in 7(14%) and left main disease in 13(26%) patients. There were elective operation in 37 cases and urgent operation in 13 cases. Result: The mean number of grafts was 3.2$\pm$1.2 per patient. Grafts used were unilateral internal thoracic artery in 43 greater saphenous vein in 37 radial artery in 7 bilateral internal thoracic arteries in 4 and right gastroepiploic artery in 2 cases Forty sequential anastomoses were performed in 18 cases. Vessels accessed were left anterior descending artery in 48 diagonal branch in 41 obtuse marginal branch in 30 right coronary artery in 24 posterior descending artery in 9 ramus intermedius in 5 and posterolateral branch in 5 anastomoses. Predischarge coronary angiography performed in 44 patients demonstrated the patency rate of 89.5%(128/143) Operative mortality was 2%(1/150) Postoperative complications were arrhythmia in 5 graft occlusion that needed reoperation in 4. perioperative myocardial infarction in 2 femoral artery thromboembolism developed after the application of IABP in 1 postoperative transient delirium in 1 peripheral compression neuropathy in 1 case. Sixteen patients(32%) were extubated at the operating room and the other patients were extubated at the mean 13$\pm$20 hours after the operation. Mean duration of stay in intensive care unit was 49$\pm$46 hours. Thirteen patients(26%) required blood transfusions perioperatively and the amount of perioperative blood transfusion was mean 0.70$\pm$1.36 pack/patient. Conclusion: OPCAB is suggested to be the ideal technique with less postoperative complication less hospitalization time and less cost.less cost.

  • PDF

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Early and Mid-Term Results of MIDCAB (최소 침습적 관상 동맥 우회술의 중단기 성적)

  • 손호성;방영호;황진욱;민병주;조양현;박성민;이성호;김광택;선경
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.827-832
    • /
    • 2004
  • Background: The significance of MIDCAB is emerging topics recently as OPCAB is going to be universalized, and long-term outcome of bypass graft surgery was proved to be more excellent than balloon dilation or stent insertion. We report our MIDCAB results in 73 patients in the last three years. Material and Method: Retrospective analysis of medical records was done from November 1, 2000 through November 31, 2003. There were 47 males and 26 females ranging in age from 31 years to 79 years (average $61.3\pm9.8$ years). Observation periods after operative procedures were 10 to 1238 days (average $763\pm319.8$ days). Left longitudinal parasternal incision as a standard procedure was done to approach the heart after dissection of the left internal thoracic artery by partial or total resection of 3rd to 5th ribs. Result: Of those patients, 46 patients were transferred to ICU after extubation at operation room and 58 patients were extubated within 3 hours after operation. Average ICU staying periods was $26.8\pm11.5$ hours. Follow-up angiography during admission was done in 36 patients and showed 100% patency. Only one patient died on the 10$^{th}$ post operative day because of sudden CVA. Complications included wound problems in 4 patients, and constructing pericardial window using thoracoscopy due to continuous pericardial effusion in 1. Permanent pacemaker was inserted in one patient owing to sick sinus syndrome. In one patient with recurrence of angina 8 months after operation, stenosis at anastomic site was found and improved with balloon dilatation. Conclusion: We were satisfied with our results of MIDCAB in single and multi-vessel coronary artery disease. These results have made the cardiologists tried to operate positively and we expect widening operative indications including hybrid revascularization.

The Analysis of Radiation Exposure of Hospital Radiation Workers (병원 방사선 작업 종사자의 방사선 피폭 분석 현황)

  • Jeong Tae Sik;Shin Byung Chul;Moon Chang Woo;Cho Yeong Duk;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2000
  • Purpose : This investigation was peformed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. Methods and Materials : The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyzed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. Results : The average of yearly radiation exposure of 347 persons was 1.52$\pm$1.35 mSv. Though it was less than 50mSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87$\pm$1.01 mSv/year, mean 1.22$\pm$0.69 mSv between 31 and 40 year old and mean 0.97$\pm$0.43 mSv/year over 41year old (p<0.001). Men received mean 1.67$\pm$1.54 mSv/year were higher than women who received mean 1.13$\pm$0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear modicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.59$\pm$1.81 msv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (p<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74$\pm$1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17$\pm$0.35 mSv/year and upper gastrointestinal room of mean 1.74$\pm$1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75$\pm$1.17 mSv/year and mean 1.50$\pm$1.39 mSv/year than other people who work in radiation area in hospital (p<0.05). Especially young doctors and technologists have the high opportunity to receive higher radiation exposure. Conclusions : The training and education of radiation workers for radiation exposure risks are important and it is necessary to rotate worker in short period in high risk area. The hospital management has to concern health of radiation workers more and to put an effort to reduce radiation exposure as low as possible in radiation areas in hospital.

  • PDF