• Title/Summary/Keyword: Angiography and Interventional Radiology

Search Result 36, Processing Time 0.023 seconds

A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients (간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰)

  • Kim, Young-Keun;Jang, Young-Ill;Heo, Young-Nam
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Non-Operative Management with Angioembolization of Grade IV and V Renal Injuries in a Hybrid Emergency Room System

  • Ahn, So Ra;Seo, Sang Hyun;Lee, Joo Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2021
  • Renal injuries occur in more than 10% of patients who sustain blunt abdominal injuries. Non-operative management (NOM) is the established treatment strategy for lowgrade (I-III) renal injuries. However, despite some evidence that NOM can be successfully applied to high-grade (IV, V) renal injuries, it remains unclear whether NOM is appropriate in such cases. The authors report two cases of high-grade renal injuries that underwent NOM after embolization in a hybrid emergency room (ER) system with a 24/7 in-house interventional radiology (IR) team. A 29-year-old male visited Wonkwang University Hospital Regional Trauma Center complaining of right abdominal pain after being hit by a rope. Computed tomography (CT) was performed 16 minutes after arrival, and the CT scan indicated a grade V right renal injury. Arterial embolization was initiated within 31 minutes of presentation. A 56-year-old male was transferred to Wonkwang University Hospital Regional Trauma Center with a complaint of right flank pain. He had initially presented to a nearby hospital after falling from a 3-m height. Thanks to the key CT images sent from the previous hospital prior to the patient's arrival, angiography was performed within 8 minutes of the patient's arrival and arterial embolization was completed within 25 minutes. Both patients were treated successfully through NOM with angioembolization and preserved kidneys. Hematoma in the first patient and urinoma in the second patient resolved with percutaneous catheter drainage. The authors believe that the hybrid ER system with an in-house IR team could contribute to NOM and kidney preservation even in high-grade renal injuries.

Emergency angioembolization performed in a hemodynamically unstable patient with grade V liver injury: The benefit of emergency angioembolization without computed tomography (혈역학적으로 불안정한 grade V 간손상에서 시행한 응급 혈관색전술: 전산화단층 촬영 없이 시행한 응급 혈관색전술의 이점)

  • Kang, Wu Seong;Park, Chan Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.235-239
    • /
    • 2019
  • High-grade liver injury is associated with high morbidity and mortality rates. We report successful emergency angioembolization and early interventional radiology support to manage a high-grade liver injury in a 29-year-old man who presented following a fall during parachute training. Upon arrival, his blood pressure was 80/40 mmHg, and emergency ultrasonography showed a liver injury with perihepatic fluid collection. The patient's blood pressure reduced to 60/40 mmHg, and emergency angiography was performed without computed tomography (CT) (door to puncture time 36 min). After angioembolization, his blood pressure returned to 120/77 mmHg. Subsequent CT revealed no additional bleeding or hollow viscus injury. He was admitted to the Intensive Care Unit and discharged without complications 30 days after admission. In this case, emergency angioembolization (without performing CT) could successfully and safely treat a hemodynamically unstable patient with a high-grade liver injury.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.

Evaluation of Present Curriculum for Devlopment of Dept. of Radiological Science Curriculum (방사선학과 교육과정 개선을 위한 현 교육과정 평가)

  • Kang, Se-Sik;Kim, Chang-Soo;Choi, Seok-Yoon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.242-251
    • /
    • 2011
  • A curriculum of study demands a change as period of time and society evolve. Therefore, at this point where changes are required, this study is to analyze and evaluate the curriculums which will enhance and improve current studies as a preceding stage. The research was based on the survey by groups of education experts and 19 universities with current curriculum of study in radiologic science, and their references. The study was focused on the scope of work by radiologic technologist, change of college systems, academic research about radiologic science, and the improvement and the future of radiologic science field in perspective to globalization and the digital era. In terms of work scope, angiography and interventional radiology at 6 to 8 schools, fluoroscopy at 4 schools, ultrasound and practices at 6 schools, magnetic resonance image at 2 schools were found to be unestablished. The basic medical subjects, humuan physiology, human anatomy and practices, medical terminology courses were set up at most schools; however, pathology at 5 schools, image anatomy at 6 schools, clinical medicine at 11 schools were yet opened. Among the basic science and engineering subjects, general biology and its practices at 11 schools, general physics and its practices at 14 schools, and general chemistry and its practices at 8 schools were established which is about a half from a total number of schools. Only 4-5 schools established digital subjects such as, health computer, computer programming, PACS which are the basic major subjects. In order to provide academic improvement in radiologic science, digitalized education and globalization, and basis for future-oriented education for the field of radiologic science, including expanded scope of work, it is acknowledged that curriculums that are opened and run at each school need to be standardized. Therefore, the need for introduction of certificate for the radiologic science education courses are suggested.