• Title/Summary/Keyword: And monitoring

Search Result 25,183, Processing Time 0.051 seconds

Quality Monitoring Method Analysis for GNSS Ground Station Monitoring and Control Subsystem (위성항법 지상국 감시제어시스템 품질 감시 기법 분석)

  • Jeong, Seong-Kyun;Lee, Sang-Uk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • GNSS(Global Navigation Satellite System) Ground Station performs GNSS signal acquisition and processing. This system generates error correction information and distributes them to GNSS users. GNSS Ground Station consists of sensor station which contains receiver and meteorological sensor, monitoring and control subsystem which monitors and controls sensor station, control center which generates error correction information, and uplink station which transmits correction information to navigation satellites. Monitoring and control subsystem acquires and processes navigation data from sensor station. The processed data is transmitted to GNSS control center. Monitoring and control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation determination module, independent quality monitoring module, and system maintenance and management module. The independent quality monitoring module inspects navigation signal, data, and measurement. This paper introduces independent quality monitoring and performs the analysis using measurement data.

Proposed Water Quality Monitoring Frequency for Risk Assessment in Korean Rivers and Streams (위해성평가 목적의 하천수 모니터링 빈도 연구: 국내상황을 고려한 적정빈도 제안)

  • Kwak, Jin Il;Yoon, Sung-Ji;Nam, Sun-Hwa;An, Youn-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.473-478
    • /
    • 2012
  • To protect human health and manage increasing hazardous chemicals in stream area, it is necessary to expand water quality hazardous items based on risk assessment with proper monitoring data. Also, it is essential to set up the suitable monitoring frequency to produce reliable exposure data to derive water quality guidelines. However, there has been no harmonized monitoring frequency for risk assessment in both domestic and international monitoring systems. In addition, the monitoring frequency for risk assessment has been selected as 'Research needs' in the International Conference on Deriving Environmental Quality Standards for the Protection of Aquatic Ecosystems (EQSPAE) of 2011. In this study, Cases of UNEP/WHO, EU, European countries, USEPA, ANZECC/ARMCANZ, CCME, Japan, and Korea were analyzed to propose the monitoring frequency for risk assessment. Monitoring frequencies depending on environmental conditions, monitoring object, measurement parameters, and monitoring duration were extensively collected. We observed that a monthly monitoring has been applied at most of organizations including EU, USEPA, and UNEP/WHO. In this study, monitoring frequency of minimum 6 times during 3 years were proposed to conduct the risk assessment based on the current domestic status. However, it is necessary to make agreements among interested parties, and perform additional studies about optimal monitoring frequency to protect the aquatic ecosystem and human health in Korean rivers and streams.

Implementation of Spectrum Analysis System for Vibration Monitoring

  • Nguyen, Thanh Ngoc;Jeon, Taehyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.27-30
    • /
    • 2019
  • Factory monitoring systems are gaining importance in wide areas of industry. Especially, there have been many efforts in implementation of vibration measurement and analysis for monitoring the status of rotating machines. In this paper, a digital signal processor (DSP) based monitoring system dedicated to the vibration monitoring and analysis on rotating machines is discussed. Vibration signals are acquired and processed for the continuous monitoring of the machine status. Time domain signals and fast Fourier transform (FFT) are used for vibration analysis. All of the signal processing procedures are done in the DSP to reduce the production and maintenance cost. The developed system could also provide remote and mobile monitoring capabilities to operator via internet connection. This paper describes the overview of the functional blocks of the implemented system. Test results based on signals from small-size single phase motors are discussed for monitoring and defect diagnosis of the machine status.

Assessment of supervision monitoring for radiation environment around the typical research reactors in China

  • Li, Sa;Wang, Haipeng;Zhang, Yanxia
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4150-4157
    • /
    • 2021
  • The supervision mode, monitoring basis and monitoring scheme of radiation environment monitoring concerning typical research reactors in China were investigated in this study. Summary and analysis were concluded of the present situation of supervised monitoring of radiation environment, such as monitoring objects, points, frequency and so on, based on the relevant data of monitoring points of four typical research reactors in China. Some experiences and existing problems were analyzed concerning the supervised monitoring of China's research reactors. Tips on topics related to strengthen the monitoring of radiation environment around the research reactors has noted.

Development of Multi-Sensor Convergence Monitoring and Diagnosis Device based on Edge AI for the Modular Main Circuit Breaker of Korean High-Speed Rolling Stock

  • Byeong Ju, Yun;Jhong Il, Kim;Jae Young, Yoon;Jeong Jin, Kang;You Sik, Hong
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.569-575
    • /
    • 2022
  • This is a research thesis on the development of a monitoring and diagnosis device that prevents the risk of an accident through monitoring and diagnosis of a modular Main Circuit Breaker (MCB) using Vacuum Interrupter (VI) for Korean high-speed rolling stock. In this paper, a comprehensive MCB monitoring and diagnosis was performed by converging vacuum level diagnosis of interrupter, operating coil monitoring of MCB and environmental temperature/humidity monitoring of modular box. In addition, to develop an algorithm that is expected to have a similar data processing before the actual field test of the MCB monitoring and diagnosis device in 2023, the cluster analysis and factor analysis were performed using the WEKA data mining technique on the big data of Korean railroad transformer, which was previously researched by Tae Hee Evolution with KORAIL.

Comparison of Field Monitoring System in case of Automatic and Manual Type Executed in Urban Deep Excavation Site (도심지 대규모 굴착공사에서 수행된 자동계측과 수동계측의 비교 사례)

  • Kim, Tae-Seob;Chung, Won-Hong;Kim, Hyun-Mo;Kim, Woong-Kyu;Jung, Chang-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1216-1223
    • /
    • 2008
  • Displacement control of earth retaining wall is recognized as the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway etc. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained three urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This task was researched in restricted case site, it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

A Study on Development of Automated Monitoring System for Road Cut Slopes (위험도로사면의 실시간 무인감시시스템 개발 연구)

  • 김춘식;이광우;윤수호;조삼덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.607-614
    • /
    • 2000
  • A cost-effective automated slope monitoring system is developed to monitor hazardous cut slopes along highways. This automated slope monitoring system consists of data-collection and visual monitoring, data-transmitting, database and internet service, and alarm system. Wire-line extensometer, automatic raingauge, and CCD camera are selected as monitoring instruments in this system, after consideration of failure characteristics of roadside cut slopes in the country. This paper describes the important features of this newly developed automated slope monitoring system.

  • PDF

Remote structural health monitoring systems for next generation SCADA

  • Kim, Sehwan;Torbol, Marco;Chou, Pai H.
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.511-531
    • /
    • 2013
  • Recent advances in low-cost remote monitoring systems have made it possible and practical to perform structural health monitoring (SHM) on a large scale. However, it is difficult for a single remote monitoring system to cover a wide range of SHM applications due to the amount of specialization required. For the remote monitoring system to be flexible, sustainable, and robust, this article introduces a new cost-effective, advanced remote monitoring and inspection system named DuraMote that can serve as a next generation supervisory control and data acquisition (SCADA) system for civil infrastructure systems. To evaluate the performance of DuraMote, we conduct experiments at two representative counterpart sites: a bridge and water pipelines. The objectives of this article are to improve upon the existing SCADA by integrating the remote monitoring system (i.e., DuraMote), to describe a prototype SCADA for civil engineering structures, and to validate its effectiveness with long-term field deployment results.

A Case Study on GNSS Based Deflection and Dynamic Characteristics Monitoring Analysis for SeoHae Bridge

  • Lee, Jae Kang;Kim, Jung Ok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.5
    • /
    • pp.389-404
    • /
    • 2017
  • The main purpose of this presented investigation is to build up the BHMS based on GNSS. This proposed monitoring system can conduct the deflection and dynamic characteristics analysis by using only GNSS positioning solution. The general bridge monitoring system being operated recently is composed of a combination of various sensors that are able to conduct deflection monitoring and dynamic characteristics monitoring analysis at the same time. However, GNSS based BHMS has the unique procedure in terms of data analysis. In the other words, GNSS positioning solution is firstly applied to deflection monitoring analysis then, this deflection analysis can be sequentially reflected in the dynamic characteristics. Unfortunately, the adjustment result of GNSS positioning solution estimated through various options and conditions and the process of monitoring analysis has not been fulfilled systematically. This means that different results or analysis value are presented according to the methodology and officers. Most of researches have been focusing on deflection monitoring analysis and some investigation regarding to dynamic characteristics is recently introduced. Moreover, it is not still reported the systematic investigation with regards to proper filtering and analysis methodology. This study was carried out based on a large amount of data, from this, various variables not reported yet are actively considered. Therefore, specific software for both monitoring analysis have been developed.

Evaluation Technique of Importance of Monitoring Systems for Earth and Rockfill Dam Safety (필댐 안전관리를 위한 계측기 중요도의 평가기법)

  • Lee, Jong-Wook;Kim, Jae-Hong;Oh, Byung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.874-882
    • /
    • 2009
  • Continuous monitoring of dam performance is essential to earth and rockfill dams safety because it has to be guaranteed for safety during construction period of course and from initial impounding to a long term maintenance period of dam. Among the 31 dams managed by Kwater at present, the proportion of dams being over 20 years after completion of construction is 42% and it is estimated that the loss rate of monitoring devices will be increase as times. Monitoring devices would be impossible to repair since those are mostly installed in the dam body and foundation. If repairing of monitoring devices is possible, the expenditure will be expensive. Therefore reasonable decision making for abandonment, repair and alternation for loss of monitoring devices would be needed through the establishment of key instrument for earth and rockfill dam safety. In this study the process of monitoring for safety were modeled by failure modes of dams, adverse conditions related to failure mode, indicators of adverse condition and monitoring devices The relationship between failure mode and monitoring devices were systematically analyzed and established and evaluation technique for qualifying the importance of monitoring devices were presented.

  • PDF