• Title/Summary/Keyword: And Recovery

Search Result 14,987, Processing Time 0.041 seconds

The Effect of a Submaximal Exercise Load on the Change in Blood Components. (최대하 운동부하가 혈액성분변화에 미치는 영향)

  • 이충훈
    • Korean Journal of Health Education and Promotion
    • /
    • v.14 no.1
    • /
    • pp.173-182
    • /
    • 1997
  • This study presents the results observed in the change in blood components of ten female students of “K” university's physical Education Department during submaximal exercise, relaxation and recovery periods. 1. After ecercise, the WBC value is higher than in relaxation time. Also within thirty minutes of the relaxation period it does not return to the normal range. 2. After exercise, the RBC value is higher than during relaxation time. Also in the recovery period, within 30 minutes it returns to the normal range. 3. After exercise. the RCT value is higher than during relaxation time. Also in the 30 minutes recovery period it returns to the normal range of relaxation. 4. After exercise, the Hb value is higher than during relaxation time. It rises slowly after exercise and returns to the relaxation range in the 30 minutes recovery period. 5. After exercise and in 10 minutes of the recovery period, the value of Glucose is lower than during relaxation time. It returns to the relaxation range in 30 minutes of the recovery period. 6. After exercise the value of protein is higher than during relaxation time. It returns to the relaxation range within ten to thirty minutes of the recovery period.

  • PDF

Fabrication and Test of a Superconducting Coil for SMES (SMES용 초전도코일 제작 및 특성)

  • 김해종;성기철;조전욱;배준한;김석환;심기덕;이언용;권영길;류경우
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.11
    • /
    • pp.557-562
    • /
    • 2003
  • To develop a stable and compact small-sized superconducting magnetic energy storage (SMES) system, which provides electric power with high quality to sensitive electric loads, we fabricated a SMES coil and tested it. Because such a large-sized superconducting coil quenches far away from its critical current, the recovery current is frequently used as a stability criterion in the coil fabrication. Therefore, we first investigated the recovery current characteristics of the large current conductor, which was used in our SMES coil fabrication. The test results indicate that the recovery currents measured in the conductor are nearly identical to those based on the single wire. This implies that the recovery current is affected by the conductor's cooling condition rather than its size and current capacity. In the SMES coil test the first quench occurred at 1250 A, which is equivalent to the stored energy of about 2 MJ. It corresponds to the quench current density of about $130A/mm^2$ This value is much higher in comparison with that reported in the other work. In addition, the first quench current of the coil agrees well with the measured recovery current of the conductor having similar cooling condition with it. This means that to determine the recovery current of a conductor is, first of all, important in the design and fabrication of a large-sized superconducting coil.

A Study on the Optimal Method of Eco-Friendly Recycling through the Comparative Analysis of the Quantitative Calculation and Scope of Recycling

  • Seung-jun WOO;Eun-gyu LEE;Chul-hyun NAM;Kang-hyuk LEE;Woo-Taeg KWON;Hee-Sang YU
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.3
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The purpose of this study is to present an efficient emission reduction ratio of plastic to reduce carbon dioxide, the main cause of greenhouse gases. Research design, data and methodology: This study calculated the absolute value of carbon dioxide by setting an equation through the emission coefficient using the US EPA's WARM model. Results: In the recycling ratio of 70%, it was found that the energy recovery ratio was 15.6%, which was the energy recovery ratio without generating carbon dioxide. When carbon dioxide is generated by changing plastic waste emissions, optimal efficiency is achieved by reducing emissions by 10% to 30% of energy recovery ratio, 20% to 50% of energy recovery ratio, and 30% to 80% or more of energy recovery ratio. Conclusions: The recycling rate should be set at a minimum of 70%, so that a carbon dioxide-free energy recovery rate could be obtained during the recycling process, supporting an eco-friendly basis for environmental policies aimed at this rate. In addition, it was possible to suggest that it is essential to reduce emissions by at least 30% for eco-friendly recycling measures that can achieve both economic and environmental feasibility in the energy recovery process through incineration during recycling in Korea.

Bladder Recovery Patterns in Patients with Complete Cauda Equina Syndrome: A Single-Center Study

  • Reddy, Ashok Pedabelle;Mahajan, Rajat;Rustagi, Tarush;Chhabra, Harvinder Singh
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.981-986
    • /
    • 2018
  • Study Design: Retrospective case series. Purpose: Cauda equina syndrome (CES) is associated with etiologies such as lumbar disc herniation (LDH) and lumbar canal stenosis (LCS). CES has a prevalence of 2% among patients with LDH and exhibits variable outcomes, even with early surgery. Few studies have explored the factors influencing the prognosis in terms of bladder function. Therefore, we aimed to assess the factors contributing to bladder recovery and propose a simplified bladder recovery classification. Overview of Literature: Few reports have described the prognostic clinical factors for bladder recovery following CES. Moreover, limited data are available regarding a meaningful bladder recovery status classification useful in clinical settings. Methods: A single-center retrospective study was conducted (April 2012 to April 2015). Patients with CES secondary to LDH or LCS were included. The retrieved data were evaluated for variables such as demographics, symptom duration, neurological symptoms, bladder symptoms, and surgery duration. The variable bladder function outcome during discharge and at follow-up was recorded. All subjects were followed up for at least 2 years. A simplified bladder recovery classification was proposed. Statistical analyses were performed to study the correlation between patient variables and bladder function outcome. Results: Overall, 39 patients were included in the study. Majority of the subjects were males (79.8%) with an average age of 44.4 years. CES secondary to LDH was most commonly seen (89.7%). Perianal sensation (PAS) showed a significant correlation with neurological recovery. In the absence of PAS, bladder function did not recover. Voluntary anal contraction (VAC) was affected in all study subjects. Conclusions: Intactness of PAS was the only significant prognostic variable. Decreased or absent VAC was the most sensitive diagnostic marker of CES. We also proposed a simplified bladder recovery classification for recovery prognosis.

Thermal Recovery Behaviors of Neutron Irradiated Mn-Mo-Ni Low Alloy Steel (중성자에 조사된 Mn-Mo-Ni 저합금강의 열처리 회복거동)

  • Jang, Gi-Ok;Ji, Se-Hwan;Sim, Cheol-Mu;Park, Seung-Sik;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.327-332
    • /
    • 1999
  • The recovery activation energy, the order of reaction and the recovery rate constant were detemined by isochronal and isothermal annealing treatment to investigate the recovery behaviors of neutron irradiated Mn-Mo-Ni low alloy steels$(fluence: 2.3\times10^{19}ncm^{-2}, 553K, E\geq1.0 MeV)$. Vickers microhardness tests were conducted to trace the recovery behavior after heat treatments. The results were analyzed in terms of recovery stages, behavior of responsible defects and recovery kinetics. It was shown that recovery occurred through two annealing stages(stage I : 703-753K, stage n : 813-873K) with re$\infty$very activation energies of 2.5 eV and 2.93 eV for each stage I and n, respectively. From the comparison of unirradiated and irradiated isochronal anneal curves, a radiation anneal hardening(RAH) peak was identified at around 813K. Most of recovery have occurred during about 120 min irrespective of isothermal annealing temperatures of 743K and 833K. Recovery rate constants were determined to be $3.4\times10^{-4}min^{-1} and 7.1\times10^{-4}min^{-1}$ for stage I and II, respectively. The order of reaction was about 2 for both recovery stages. Comparing the obtained data with those of previously reported results on neutron irradiated Mn- Mo- Ni steels, the thermal recovery be­havior of the present material seems to occur by the dissociation of point defect clusters formed during irradiation, and by the recombination process of self-interstitials and vacancies from dissociated vacancy clusters.

  • PDF

Quench and recovery characteristics of HTS film after fault current (과도전류 후의 고온초전도체 박막의 퀜치/회복 특성)

  • 박을주;김진석;설승윤
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.16-19
    • /
    • 2003
  • Quench and recovery process of high-temperature-superconductor (HTS) film deposited on the sapphire substrate is studied numerically. The quench is developed by fault current and the superconductivity is recovered by convection of heat into coolant. After the fault current. the HTS film experiences the quench state. current sharing state. and finally recovers the superconductivity. Numerical results of this study are compared to the previous experimental results. and shows that this numerical work can explain the mechanism of quench/recovery characteristics of HTS film.

Quench and recovery characteristics of HTS film after fault current (고온초전도체 박막의 퀜치/회복 특성)

  • 설승윤;김진석;박을주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.181-184
    • /
    • 2003
  • Quench and recovery process of high-temperature -superconductor (HTS) film deposited on the sapphire substrate is studied numerically. The quench is developed by fault current and the superconductivity is recovered by convection of heat into coolant. After the fault current, the HTS film experiences the quench state, current sharing state, and finally recovers the superconductivity. Numerical results of this study are compared to the previous experimental results, and shows that this numerical work can explain the mechanism of quench/recovery characteristics of HTS film.

  • PDF

Modeling TCP Loss Recovery for Random Packet Losses (임의 패킷 손실에 대한 TCP의 손실 복구 과정 모델링 및 분석)

  • Kim, Beom-Joon;Kim, Dong-Yeon;Lee, Jai-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4B
    • /
    • pp.288-297
    • /
    • 2003
  • The fast retransmit and fast recovery algorithm of TCP Reno, when multiple packets in the same window are lost, cannot recover them without RTO (Retransmission Timeout). TCP New-Reno can recover multiple lost packets by extending fast recovery using partial acknowledgement. If the retransmitted packet is lost again during fast recovery, however, RTO cannot be avoided. In this paper, we propose an algorithm called "Duplicate Acknowledgement Counting(DAC)" to alleviate this problem. DAC can detect the retransmitted packet loss by counting duplicate ACKs. Conditions that a lost packet can be recovered by loss recovery of TCP Reno, TCP New-Reno and TCP New-Reno using DAC are derived by modeling loss recovery behavior of each TCP. We calculate the loss recovery probability for random packet loss probability numerically, and show that DAC can improve loss recovery behavior of TCP New-Reno.

The Effect of Chest Meridian Massage on Post- Anesthetic Recovery of General Anesthesia Patients (흉부경락마사지가 충수돌기 절제술 환자의 마취 후 회복에 미치는 효과)

  • Lee, Byung-Yup;Shon, Kyung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.17 no.4
    • /
    • pp.612-621
    • /
    • 2005
  • Purpose: This study aims at confirming the effects of the chest meridian massage on the post-anesthetic recovery of general anesthesia appendectomy patients. Method: The research was post-test designed as a nonequivalent control group among quasi-experiments tested. The data was collected from June 20, 2003 to October 14, 2003 at a hospital in P city. In the collected data, using SPSS Win 10.0 program, these general features were analyzed by real numbers and percentages; the homogeneity among variables by $X^2-test$ and t-test and the research hypothesis by the t-test. Result: Hypothesis 1; The experimental group receiving the treatment of the chest meridian massage will have a much higher post-anesthetic recovery score than that of the control group not receiving it was supported(t=2.544, p=.014). Hypothesis 2; The experimental group receiving the treatment of the chest meridian massage will have a much shorter time of stay in the recovery room than that of the control group not receiving it was supported(t=-4.919, p=.000). Conclusion: According to these results, it may be concluded that Chest Meridian Massage is effective in producing a higher level of post-anesthetic recovery score and helps appendectomy patients reduce the time of stay in the recovery room. Therefore the chest meridian massage can be considered as an intervention therapy for directly nursing general anesthesia appendectomy patients.

  • PDF

Implementation of Blind Source Recovery Using the Gini Coefficient (Gini 계수를 이용한 Blind Source Recovery 방법의 구현)

  • Jeong, Jae-Woong;Song, Eun-Jung;Park, Young-Cheol;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • UBSS (unde-determined blind source separation) is composed of the stages of BMMR (blind mixing matrix recovery) and BSR (blind source recovery). Generally, these two stages are executed using the sparseness of the observed data, and their performance is influenced by the accuracy of the measure of the sparseness. In this paper, as introducing the measure of the sparseness using the Gini coefficient to BSR stage, we obtained more accurate measure of the sparseness and better performance of BSR than methods using the $l_1$-norm, $l_q$-norm, and hyperbolic tangent, which was confirmed via computer simulations.