• 제목/요약/키워드: Anatomical locking plate

검색결과 18건 처리시간 0.021초

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

경골 천정(pilon) 골절의 최신 치료 (Current Treatment of Tibial Pilon Fractures)

  • 이준영
    • 대한족부족관절학회지
    • /
    • 제15권2호
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판 (Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation)

  • 최준철;나화엽;이영상;김우성;오경수;송우석;김세준
    • 대한정형외과스포츠의학회지
    • /
    • 제8권2호
    • /
    • pp.115-120
    • /
    • 2009
  • 목적: 배측 분쇄가 있는 원위부 요골 골절에서 세가지 수술법에 따른 결과를 알아보고자 하였다. 대상 및 방법: 2006년 4월부터 2009년 5월 사이의 60세 이상의 배측 분쇄가 있는 원위부 요골 골절이 있으면서 불안정성을 보인 환자 49명을 대상으로 하였다. 수술 1년 후까지의 방사선학적 추시관찰을 통하여 골절 정복의 유지 여부 및 Mayo Wrist Score를 통한 임상적 결과를 비교하였으며, 일원배치 분산분석(One-Way ANOVA)을 통하여 연관성을 검정하였다. 결과: 세군 모두에서 수술 직후에는 만족스러운 정복을 얻을 수 있었으나, 추시 소견상 외고정장치 단독으로 고정시에는 외고 정장치에 동종골 이식을 추가한 군 및 수장측 잠김 압박 금속판을 사용한 군에 비해서 유의하게 정복 소실이 있음을 확인하였다.(p<0.05) Mayo Wrist Score는 세군 모두에서 의미있는 차이는 없었다. 결론: 배측 분쇄가 심한 원위부 요골의 관절내 골절에서 외고정 장치만 사용한 치료시에는 해면골 결손으로 인한 정복유지의 어려움이 있어 불충분한 치료로 판단된다.

  • PDF

Preventing Varus Deformity in Senile Patients with Proximal Humerus Fractures and Poor Medial Support

  • Kim, Young-Kyu;Kang, Suk-Woong;Kim, Jin-Woo
    • Clinics in Shoulder and Elbow
    • /
    • 제19권4호
    • /
    • pp.216-222
    • /
    • 2016
  • Background: We investigated the effectiveness of fibular strut allograft augmentation of proximal humerus fractures to prevent varus deformity in patients over the age of 65 years with insufficient medial support. Methods: We analyzed the clinical and radiological outcomes of locking plate fixation with adjunct fibular strut allograft augmentation in 21 patients with proximal humeral fractures. The inclusion criteria were age (65-year-old or older); presence of severe medial comminution; inadequate medial support; and those who could participate in at least a one year follow-up. The average age was 76.4 years. We analyzed each patient's Constant score, our indicator of clinical outcome. As radiological parameters, we analyzed time-to-bone union; restoration of the medial hinge; difference between the immediately postoperative and the last follow-up humeral neck-shaft angles;; and anatomical reduction status, which was assessed using the Paavolainen method. Results: A successful bone union was achieved in all patients at an average of 11.4 weeks. We found that the average Constant score was 74.2, showing a satisfactory outcome. The average difference in the humeral neck-shaft angles between the immediately postoperative time-point and at the final follow-up was $3.09^{\circ}$. According to the Paavolainen method, the anatomical reduction was rated excellent. The medial hinge was restored in 14 of 21 patients. Although we did not find evidence for osteonecrosis, we found that a single patient had a postoperative complication of screw cut-out. Conclusions: Fibular strut allografting as an adjunct treatment of proximal humeral fractures may reduce varus deformity in patients with severe medial comminution.

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 - (Treatment of Open Proximal Humerus Fracture by Gunshot)

  • 김성재;이재후;천용민
    • Clinics in Shoulder and Elbow
    • /
    • 제15권1호
    • /
    • pp.37-42
    • /
    • 2012
  • 목적: 총상에 의한 상완골 골절 증례를 통해 치료의 원칙에 대하여 고찰한다. 대상 및 방법: 28세 남자가 좌측 상완부의 총상으로 수상 후 5일에 응급실로 내원하였다. 상지의 신경 및 혈관 손상의 징후 및 타장기의 손상은 없었으며, 생체징후는 안정적이었다. 수상 당시 타 병원에서 총상에 대한 변연 절제술 및 세척술 후에 일차적 봉합술을 시행받았으며, 상완부의 전외측에 5 cm 가량의 오염된 상처가 있었다. 본원에서 변연절제술 및 탄환 파편의 제거술을 시행하고 외고정을 통하여 해부학적 정렬을 유지하였다. 술 후 8일까지 상처에 대한 무균적 소독을 시행하였으며, 정맥 항생제를 유지하였다. 술 후 9일째에 광범위 변연 절제술 및 항생제를 섞은 시멘트 구슬 삽입술을 시행하였다. 감염이 호전되는 소견을 보여, 시멘트 구슬 삽입 2주째에 외고정 장치를 제거하고 외고정 핀 삽입부의 피부 봉합술을 시행하였다. 1주 후에, 금속판을 이용하여 내고정을 하였다. 결과: 유합술 후 3 개월째, 만족스러운 상완골의 정렬과 골 유합을 얻었다.