• Title/Summary/Keyword: Anatomic study

Search Result 471, Processing Time 0.037 seconds

Repeated Pulmonary Metastasectomy in Patients with Osteosarcoma (골육종 환자의 반복적 폐전이 절제술)

  • Lee, Jin-Gu;Shin, Kyoo-Ho;Park, In-Kyu;Chung, Kyung-Young;Song, Seung-Jun;Kim, Dae-Joon
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.607-612
    • /
    • 2007
  • Background: Surgical resection is a standard treatment for pulmonary metastases in patients with osteosarcoma, but the role of performing repeated resections is not clear. This study was designed to clarify the feasibility of performing a repeated pulmonary metastasectomy and the prognostic factors for pulmonary metastases in patients with osteosarcoma. Material and Method: Between January 1990 and July 2005, 62 patients with osteosarcoma were diagnosed with pulmonary metastases and 36 patients underwent pulmonary resection. We reviewed the patients retrospectively. Result: The total number of pulmonary metastasectomies was 62 in 30 patients. Among 36 patients, 18 had a second metastasectomy, 7 had a third metastasectomy, and one patient had a fourth metastasectomy. There was no distinctive difference between the first and second metastatectomy in terms of median survival time, and the 3-year and 5-year survival rate (first resection: 20.5 months, 32.0% and 29,4%; second resection: 11.3 months, 34.9% and 34.%). However, the median survival time (7.1 months) was shorter in patients with a third metastatectomy than in patients with one metastatectomy (p=0.01). In long-term survivors, the number of female patients, patients with a disease free time longer than 12 months, patients with a single metastasis and patients with anatomic resection was larger when compared to non-long term survivors, but showed no statistical significance. Conclusion: Repeated pulmonary metastasectomy is expected to prolong survival time in patients with osteosarcoma, and is expected to increase long-term survival in selected cases. Further studies with a large number of patients are necessary.

Comparative Analysis of Fracture Angulation between Parallel Pinning and Plate Fixation Techniques in the Management of 5th Metacarpal Fractures (제 5 수지 중수골 골절에서 평행 핀 또는 플레이트 고정술 이후 골절각 변화에 대한 비교 연구)

  • Lee, Myungchul;Shin, Hyojung;Choi, Hyungon;Kim, Jeenam;Shin, Donghyeok
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.230-238
    • /
    • 2018
  • Purpose: Metacarpal fractures are common injuries of the hand. They are treated using closed reduction (CR) or open reduction (OR) techniques. The management strategy depends on fracture site characteristic and fixation methods. In this study, we evaluated pre- and postoperative fracture angulation, when metacarpal fractures bad been treated using two different techniques: CR with parallel transverse pinning and OR with plate fixation. Methods: Forty-six patients undergoing anatomic reduction to treat extra-articular metacarpal fractures were recruited. They were included in one of two therapeutic groups: Group 1, CR with parallel transverse pinning (n=21); Group 2, OR with plate fixation (n=25). Fracture angulation values have been measured on pre- and postoperative radiologic images. Values were compared between pre- and postoperative states, and between corresponding measurements of each group. Results: All extra-articular metacarpal fractures were successfully treated without wound related complications or the limit of joint motion. Both groups demonstrated adequate reduction at immediate postoperative period (postoperative angulation of group 1, $20^{\circ}{\pm}7^{\circ}$; group 2, $19^{\circ}{\pm}5^{\circ}$). During the observation at follow-up period, Group 1 exhibited slight recurrence (follow-up angulation of group 1, $24^{\circ}{\pm}10^{\circ}$). Nonetheless, Group 2 showed adequate reduction state in both immediate postoperative and long-term follow-up periods (follow-up angulation of group 2, $18^{\circ}{\pm}6^{\circ}$). Conclusion: Extra-articular metacarpal fractures were successfully restored without functional complications. CR with parallel transverse pinning method exhibited recurrence after pin removal, which necessitates cautious postoperative exercise and monitoring.

Ultrasound-Guided Axillary Brachial Plexus Block, Performed by Orthopedic Surgeons (정형외과 의사가 시행한 초음파 유도 액와 상완 신경총 차단술)

  • Kim, Cheol-U;Lee, Chul-Hyung;Yoon, Ja-Yeong;Rhee, Seung-Koo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.513-521
    • /
    • 2018
  • Purpose: The purpose of this study was to assess the effectiveness and complications of an ultrasound-guided axillary brachial plexus block performed by orthopedic surgeons. Materials and Methods: From March to May 2017, an ultrasound-guided axillary brachial plexus block was performed on a total of 103 cases of surgery. A VF13-5 transducer from Siemens Acuson X300 was used. The surgical site was included in the range of the anatomic sensory distribution of the blocked nerve, except for the case where an operation time of more than 2 hours was expected due to multiple injuries and the operation of the upper arm. The procedure was performed by 2 orthopedic surgeons in the same method using 50 ml of solution (20 ml of lidocaine HCl in 2%, 20 ml of ropivacaine in 0.75%, 10 ml of normal saline in 0.9%). The success rate of anesthesia induction during surgery, anesthetic induction time, anatomical range of operation, duration of postoperative analgesia and complications were investigated. Results: The results from the 2 practices were similar. The anesthesia was successful in 100 out of 103 patients (97.1%). In these patients, the average needling time was 5.5 minutes (2.5-13.2 minutes), the average induction time to complete anesthesia was 18.4 minutes (5-40 minutes), and the average duration of postoperative analgesia was 402.8 minutes (141-540 minutes). The post-anesthesia immediate complications were dizziness in 1 case, nausea and vomiting in 4 cases, and peri-oral numbness in 2 cases, but surgery was performed without problems. All these 7 cases with complications recovered on the same day. A total of 3 cases failed with anesthesia, and they were treated by an injection with local anesthesia in the operation room in 2 cases and switched to general anesthesia in 1 case. Conclusion: An ultrasound-guided axillary brachial plexus block, which was performed by orthopedic surgeons allows anesthesia in a brief period and the high success rates of anesthesia for certain surgeries of the elbow and surgeries on forearm, wrist and hand. Therefore, it can reduce the waiting time to the operating room. This technique is a relatively safe procedure and dose selective anesthesia is possible.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Expression of Phospholipase C Isozymes in Human Lung Cancer Tissues (인체 폐암조직에서 Phospholipase C 동위효소의 발현양상)

  • Hwang, Sung-Chul;Mah, Kyung-Ae;Choi, So-Yeon;Oh, Yoon-Jung;Choi, Young-In;Kim, Deog-Ki;Lee, Hyung-Noh;Choi, Young-Hwa;Park, Kwang-Ju;Lee, Yi-Hyeong;Lee, Kyi-Beom;Ha, Mahn-Joon;Bae, Yoon-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.310-322
    • /
    • 2000
  • Background : Phospholipase C(PLC) plays an important role in cellular signal transduction and is thought to be critical in cellular growth, differentiation and transformation of certain malignancies. Two second messengers produced from the enzymatic action of PLC are diacylglycerol (DAG) and inositol 1, 4, 5-trisphosphate (IP3). These two second messengers are important in down stream signal activation of protein kinase C and intracellular calcium elevation. In addition, functional domains of the PLC isozymes, such as Src homology 2 (SH2) domain, Src homology 3 (SH3) domain, and pleckstrin homology (PH) domain play crucial roles in protein translocation, lipid membrane modificailon and intracellular memrane trafficking which occur during various mitogenic processes. We have previously reported the presence of PLC-${\gamma}1$, ${\gamma}2$, ${\beta}1$, ${\beta}3$, and ${\delta}1$ isozymes in normal human lung tissue and tyrosine-kinase-independent activation of phospholipase C-${\gamma}$ isozymes by tau protein and AHNAK. We had also found that the expression of AHNAK protein was markedly increased in various mstologic types of lung can∞r tissues as compared to the normallungs. However, the report concerning expression of various PLC isozymes in lung canærs and other lung diseases is lacking. Therefore, in this study we examined the expression of PLC isozymes in the paired surgical specimens taken from lung cancer patients. Methods : Surgically resected lung cancer tissue samples taken from thirty seven patients and their paired normal control lungs from the same patients, The expression of various PLC isozymes were studied. Western blot analysis of the tissue extracts for the PLC isozymes and immunohistochemistry was performed on typical samples for localization of the isozyme. Results : In 16 of 18 squamous cell carcinomas, the expression of PLC-${\gamma}1$ was increased. PLC-${\gamma}1$ was also found to be increased in all of 15 adenocarcinoma patients. In most of the non-small cell lung cancer tissues we had examined, expression of PLC-${\delta}1$ was decreased. However, the expression of PLC-${\delta}1$ was markedly increased in 3 adenocarcinomas and 3 squamous carcinomas. Although the numbers were small, in all 4 cases of small cell lung cancer tissues, the expression of PLC-${\delta}1$ was nearly absent. Conclusion : We found increased expression of PLC-${\gamma}1$ isozyme in lung cancer tissues. Results of this study, taken together with our earlier findings of AHNAK protein-a putative PLD-${\gamma}$, activator-over-expression, and the changes observed in PLC-${\delta}1$ in primary human lung cancers may provide a possible insight into the derranged calcium-inositol signaling pathways leading to the lung malignancies.

  • PDF

Bronchial Brushing and Bronchial Washing for Diagnosis of Central Lung Cancer (중심형 폐암 진단을 위한 기관지찰과술과 기관지세척술)

  • Park, Ki-Su;Park, Jae-Yong;Cha, Seung-Ick;Son, Ji-Woong;Kim, Kwan-Young;Kim, Jeong-Seok;Chae, Sang-Cheol;Kang, Tae-Kyong;Park, Tae-In;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.817-825
    • /
    • 1999
  • Background : Forceps biopsy, bronchial brushing, and bronchial washing are used in conjunction with bronchoscopy to provide specimens for histologic and cytologic analysis in patients with suspected lung cancer. This study was performed to evaluate how many times brushing should be done and how much fluid should be used during bronchial washing for increasing diagnostic yield, and to evaluate which combination of these procedures gives the highest diagnostic yield. Methods : Forty patients, with suspected lung cancer, who had bronchoscopically visible lesions were enrolled in this prospective study. During one bronchoscopic examination four forceps biopsies, four bronchial brushings, and bronchial washing were done in all patients. The patients were divided into four groups by the amount of normal saline used for bronchial washing; group I, 10 ml ; group II, 20ml ; group III 30ml, and group IV, 40ml. We analyzed the results in 36 patients confirmed as lung cancer. Results : The diagnostic sensitivity of bronchial washing before and after forceps biopsy and bronchial brushing were 36% and 28%, respectively. The cumulative diagnostic sensitivity of bronchial washing was 47% and significantly higher than that of bronchial washing before or after forceps biopsy and bronchial brushing (p<0.05). The diagnostic sensitivity of bronchial washing with saline of 30ml was significantly higher than that of bronchial washing with saline of 10ml or 20ml (p<0.05). The diagnostic sensitivity of the first brushing was 75%, the second brushing 78%, the third brushing 83%, and the fourth brushing 67%. With repeated brushing up to three times, the diagnostic sensitivity increased to 92% (p<0.05). However, inclusion of the fourth brushing did not give a further increase of the diagnostic sensitivity. The diagnostic sensitivity of forceps biopsy was 86%. The diagnostic sensitivities of forceps biopsy by the type of bronchial lesion were as follows: tumor, 88%; infiltration, 67%; infiltration with nodularity, 80%; and collapse, 100%. The combination of forceps biopsy and bronchial washing gave a diagnostic sensitivity of 89%. The diagnostic sensitivity of combining forceps biopsy with bronchial brushing was 97%. Addition of bronchial washing did not increase the diagnostic yield over forceps biopsy and bronchial brushing. Conclusion : In patients with central lung cancer, forceps biopsies and repeated brushings up to three times should be done for maximal diagnostic yield.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

The Radioprotective Effect and Mechanism of Captopril on Radiation Induced-Heart Damage in Rats (방사선 조사 후 발생한 흰쥐 심장손상에서 Captopril의 방어역할과 기전)

  • Chang Seung-Hee;Lee Kyung-Ja;Koo Heasoo
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.40-54
    • /
    • 2004
  • Purpose : Captopril (angiotension converting enzyme inhibitor) is known to have a radioproptective effect in the lungs, intestines and skin, but its effect in the heart is unclear. To investigate the radioprotectlve efiect and mechanism of captopril on the heart, the histopathological changes and immunohistochemical stains were compared with radiation alone, and radiation combined with captopril, in the rats. Materials and Methods : The histopathological changes and immunohistochemical stains ($TNF{\alpha}$, $TGF{\beta}1$, PDGF and FGF2) were examined in the radiation alone and the combined captopril and radiation groups, 2 and 8 weeks after irradiation. Each group consisted of 8 to 10 rats (Sprague-Dawley). Irradiation (12.5 Gy) was given to the left hemithorax in a single fraction. Captopril (50 mg/Kg/d) mixed with water, was given orally and continuously from the first week prior to, up to the 8th week of the experiment. Results : In the radiation alone group, the ventricle at 2 weeks after irradiation showed prominent edema (p=0.082) and fibrin deposit (p=0.018) compared to the control group. At 8 weeks, the edema was decreased and fibrosis increased compared to those at 2 weeks. The histopathological changes of the combined group were similar to those of the control group, due to the reduced radiation toxicity at 2 and 8 weeks. The endocardial fibrin deposit (p=0.047) in the atrium, and the interstitial fibrin deposit (p=0.019) and edema (p=0.042) of the ventricle were reduced significantly in the combined group compared to those in the radiation alone group at 2 weeks. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$, PDGF and FGF-2 in the radiation alone group were more increased than in the control group, especially in the pericardium and endocardium of the atrium at 2 weeks. At 8 weeks, the pericardial $TNF-{\alpha}$ and $TGF-{\beta}1$ in the radiation alone group continuously increased. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were decreased in the combined group at 2 weeks. At 8 weeks, the expressions of $TNF-{\alpha}$ in the atrial and ventricular pericardia were markedly reduced (p=0.049, p=0.009). Conclusion : This study revealed that the early heart damage induced by radiation can be reduced by the addition of captopril in a rat model. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were further decreased in the combined compared to the radiation alone group at both 2 and 8 weeks. From these results, it may be concluded that these cytokines probably play roles in the radioprotective mechanism of captopril from the radiation-induced heart toxicity, similarly to in other organs.

Physicochemical Characteristics of Silky Fowl(Gallus domesticus var. silkies) (백봉오골계육의 이화학적 특성)

  • Cho, Chae-Min;Park, Chung-Kil;Lee, Min-Young;Lew, In-Deok
    • Food Science of Animal Resources
    • /
    • v.26 no.3
    • /
    • pp.306-314
    • /
    • 2006
  • In this study, the anatomic characteristics and the contents of nutritional ingredients and minerals of silky fowl and yeonsan ogolgye was investigated. Silky fowl is covered with white silky feather. There is a pinch of vertical white tassel on peak of the head, especially a silky fowl cock. The crown of a silky fowl has a nickname of phoenix crown, the crown of a cock is mostly like a rose, while that of a hen like strawberry or mulberry. The ear of silky fowl is mostly peacock green(Light blue turquoise), bronze for a small part. Peacock green is most common for Silky Fowl with a age of $60{\sim}150$ days, over the age of 150 days, the peacock green will be gradually replaced by purplish red. Beaks are leaden blue, short and stout while the face is smooth and fine. The lower jaw of silky fowl has comparatively long tiny hair, similar to beard. The two legs of silky fowl are covered with a handful of feather, or known as 'Putting on trousers'. Each leg of silky fowl has five talons. The whole skin, eyes, mouth, talons of silky fowl are grey black The bone and marrow of silky fowl are light black the periosteum is black. The whole meat, internal organs and abdominal fat of sillry fowl aye black the heart and leg meat are light black. Silky fowl meat had lower moisture and lipids content, but higher Ash and protein content than meats of yeosan ogolgye and general chickens. For mineral contents of leg muscle and breast muscle, silky fowl had higher contents of phosphorus (P), iron (Fe), potassium (K), zinc (Zn) than those of yeonsan ogolgye, while yeonsan ogolgye had higher contents of calcium (Ca) than that of silky fowl. The contents of iron (Fe) and zinc (Zn) is higher in leg muscle than in breast muscle for the silky fowl and yeonsan ogolgye. Leg muscle of silky fowl contains a lot of iron (Fe), about 4 times as much as that of leg muscle of yeonsan ogolgye. For the silky fowl and the yeonsan ogolgye, leg muscles contains a lot of zinc (Zn), about 5 times, 4 times respectively as much as that of breast muscle.