• Title/Summary/Keyword: Anastigmat

Search Result 12, Processing Time 0.032 seconds

Optical design of flat field anastigmatic three-mirror telescope (Flat Field Anastigmat 조건을 만족하는 3반사 망원경 광학계 설계)

  • 최세철;김현규;김연수
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.175-182
    • /
    • 1997
  • To design a high resolution three-mirror telescope for visible spectral region, initial design technique based on the generation of flat field anastigmatic solutions limited by mechanical structure was proposed. An initial design of the three-mirror telescope that features relatively high focal ratio(F/14.5), large aperture diameter(600 mm), and squared field of view(0.27$^{\circ}$$\times$1.3$^{\circ}$) was done using an initial design program. Code V was used to optimized the initially designed optical system. As a result, MTF value of the telescope was about 0.5 at Nyquist frequency in each field except for the edge of the CCD.

  • PDF

4 반사경 ANASTIGMAT 의 ZOOMING 에 관한 연구

  • 나승유;이상수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.59-67
    • /
    • 1988
  • 연속적으로 aplanat 조건을 만족하는 4 반사경의 zooming에서 aplanat 4구면 반사광학계가 갖는 astigmatism을 줄이기 위하여 4구면 중 하나의 반사경에 원추곡면을 사용함으로써 줌 궤적상의 한점에서 anatsigmat 조건을 만족하도록 하였다. 이방법에 의한 astigmatism 의 보정효과는 제 1 면에 ellipsoid를 사용하였을 때 가장 우수하였다.

  • PDF

Design and Manufacture of an Off-axis Aluminum Mirror for Visible-light Imaging

  • Zhang, Jizhen;Zhang, Xin;Tan, Shuanglong;Xie, Xiaolin
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.364-371
    • /
    • 2017
  • Compared to one made of glass, an aluminum mirror features light weight, compact design, low cost, and quick manufacturing. Reflective mirrors and supporting structures can be made from the same material, to improve the athermal performance of the system. With the rapid development of ultraprecise machining technologies, the field of applications for aluminum mirrors has been developed rapidly. However, most of them are rotationally symmetric in shape, and are used for infrared applications. In this paper, the design and manufacture of an off-axis aluminum mirror used for a three-mirror-anastigmat (TMA) optical system at visible wavelengths is presented. An optimized, lightweight design provides a weight reduction of more than 40%, while the surface deformation caused by earth's gravity can meet the required tolerance. The two pieces of an off-axis mirror can be diamond-turned simultaneously in one setup. The centrifugal deformation of the off-axis mirror during single-point diamond turning (SPDT) is simulated through the finite-element method (FEM). The techniques used to overcome centrifugal deformation are thoroughly described in this paper, and the surface error is reduced to about 1% of the original value. After post-polishing, the form error is $1/30{\lambda}$ RMS and the surface roughness is better than 5 nm Ra, which can meet the requirements for visible-light imaging.

Structural Design Development of GOCI

  • Yeon Jeoung-Heum;Kang Song-Doug;Kim Jongah;Kang Gurrl.sil;Myung Hwan-Chun;Youn Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.104-107
    • /
    • 2005
  • COMS(Communication, Ocean, and Meteorological Satellite) is the geostationary satellite for the mission of satellite communication, ocean monitoring, and meteorological service. It is scheduled to be launched at the end of 2008. Ocean payload of COMS named as GOCI(Geostationary Ocean Color Imager) observes ocean color and derives the chlorophyll concentrlition, the concentration of dissolved organic material and so on. In operational oceanography, satellite derived data products are used to provide forecasting and now casting of the ocean and coastal water state. In this work, conceptual design of structural part of GOCI is carried out and two baseline concepts are proposed. The one is dioptric module that uses lens system and the other is TMA(Three Mirror Anastigmat) module that uses mirror system. Trade-off studies between two concepts are investigated by considering optical and mechanical performances. Finally, on-going tasks and future development plan are briefly discussed.

  • PDF

Alignment estimation performance of Multiple Design Configuration Optimization for three optical systems

  • Oh, Eun-Song;Kim, Seong-Hui;Kim, Yun-Jong;Lee, Han-Shin;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.31.1-31.1
    • /
    • 2011
  • In this study, we investigated alignment state estimation performances of the three methods i.e. merit function regression (MFR), differential wavefront sampling (DWS) and Multiple Design Configuration Optimization (MDCO). The three target optical systems are 1) a two-mirror Cassegrain system for deep space Earth observation, 2) intermediate size three-mirror anastigmat for Earth ocean monitoring, and 3) extremely large segmented optical system for astronomical observation. We ran alignment state estimation simulation for several alignment perturbation cases including 1mm to 10mm in decenter and from 0.1 to 1 degree in tilt perturbation error for the two-mirror Cassegrain system. In general, we note that MDCO shows more competitive estimation performance than MFR and DWS. The computational concept, case definition and the simulation results are discussed with implications to future works.

  • PDF

Null lens design for testing of elliptical surface (타원면경 측정 Null 렌즈 설계)

  • 김연수
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.246-249
    • /
    • 2000
  • The null lens is designed for testing the elliptical (conic constant>O) mirror which is the third mirror of the off-axis Three Mirror Anastigmat (TMA) designed as a high resolution camera for remote sensing. The mixed type design is proposed as a new design type which has a small annular flat mirror, but has as twice sensitivity as the autostigmatic type design. It is also shown that the null lens of the Mixed type is better than that of the autostigmatic type in terms of the sensitivity of the wavefront distortion which is given as the magnitude of optical path difference with respect to the change of each surface parameters such as the radius of curvature, thickness of lenses and tested mirror.

  • PDF

Design of null lenses for testing of hyperbolic surfaces (쌍곡면 측정 null 렌즈 설계)

  • 김연수;김병윤;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.352-355
    • /
    • 2001
  • A null lens is designed for testing the hyperbolic mirror which is the first mirror of the off-axis three mirror anastigmat(TMA) designed as a high resolution camera for remote sensing. To choose a better null lens system for the hyperbolic surface under test, both autostigmatic and mixed type null lenses are designed and analysed for sensitivity with respect to change of each surface parameter such as the radius of curvature and the thickness.

  • PDF

Optical Design of a High-numerical-aperture Objective with a Reflective Focal Reducer (반사형 Focal Reducer를 가지는 높은 개구수의 대물렌즈 설계)

  • Jong Ung Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.248-260
    • /
    • 2023
  • A 0.5-numerical-aperture (NA) refractive-reflective objective, composed of a low-NA refractive and a reflective focal reducer, is designed. A 0.25-NA Lister objective is used for the refractive. A two-spherical-mirror system, corrected for spherical aberration, coma, and astigmatism is used for the reflective focal reducer. In spite of high NA, the refractive-reflective objective has an 18-mm working distance and improved imaging performance, compared to the 0.25-NA Lister objective.

Initial On-Orbit Modulation Transfer Function Performance Analysis for Geostationary Ocean Color Imager

  • Oh, Eun-Song;Kim, Sug-Whan;Cho, Seong-Ick;Ryu, Joo-Hyung;Ahn, Yu-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • The world's first geostationary ocean color imager (GOCI) is a three-mirror anastigmat optical system 140 mm in diameter. Designed for 500 m ground sampling distance, this paper deals with on-orbit modulation transfer function (MTF)measurement and analysis for GOCI. First, the knife-edge and point source methods were applied to the 8th band (865 nm) image measured April 5th, 2011. The target details used are the coastlines of the Korean peninsula and of Japan, and an island 400 meters in diameter. The resulting MTFs are 0.35 and 0.34 for the Korean East Coastline and Japanese West Coastline edge targets, respectively, and 0.38 for the island target. The daily and seasonal MTF variations at the Nyquist frequency were also checked, and the result is $0.32{\pm}0.04$ on average. From these results, we confirm that the GOCI on-orbit MTF performance satisfies the design requirements of 0.32 for 865 nm wavelength.