• Title/Summary/Keyword: Analytical determination

Search Result 1,490, Processing Time 0.034 seconds

First Derivative Spectrophotometric and Gas-Liquid Chromatographic Determination of Caffeine in Foods and Pharmaceuticals III. Simultaneous assay of caffeine and some antihistaminics

  • Abdel-Moety, Ezzat M.;El-Tarras, Mohamed F.;El-Zeany, Badr-Eldin A.;Kelani, Khadiga O.
    • Archives of Pharmacal Research
    • /
    • v.13 no.3
    • /
    • pp.215-220
    • /
    • 1990
  • Two different, derivative spectrophotometric and gas-liquid chromatographic, procedures for direct quantitation of caffeine and some commonly dispensed antihistaminics in bulk forms, in their laboratory prepared mmixtures and in dosage formulations, have been investigated. The limit, sensitivity reproducibility and accuracy of each method were studied for each individual drug substance and in some usual pharmaceutical formulations.

  • PDF

Studies on the Colorimetric Determination of Drugs with Phosphomolybdic Acid. I. Colorimetric Determination of Ampicillin with Phosphomolybdic acid

  • Lee, Wang-Kyu;Yoo, Byung-Tai;Kang, Gil-Jong
    • YAKHAK HOEJI
    • /
    • v.18 no.3
    • /
    • pp.190-196
    • /
    • 1974
  • A new colorimetric method established for the determination of ampicillin was based on the reductions of phosphomolybdic acid by ampicillin to be resutled in a molybdenum blue which showed a mezimal absorbance at 770nm. The pH effects on a molybodenum blue solution was dependent significantly on temeprature, but the wave-length shift was not effected by the molybdenum blue.

  • PDF

Spectrophotometric and Kinetic Determination of Some Sulphur Containing Drugs in Bulk and Drug Formulations

  • Walash, M.I.;El-Brashy, A.M.;Metwally, M.S.;Abdelal, A.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.517-524
    • /
    • 2004
  • Two simple and sensitive spectrophotometric methods were developed for the determination of carbocisteine, penicillamine, ethionamide and thioctic acid in bulk and in their pharmaceutical preparations using alkaline potassium permanganate as an oxidizing agent. The first one involves determination of ethionamide and thioctic acid by spectrophotometric investigation of the oxidation reaction of the two drugs. The second method involves determination of carbocisteine and penicillamine by kinetic studies of the oxidation reaction of these two drugs at room temperature for a fixed time of 20 minutes. The absorbance of the colored manganate ions was measured at 610 nm in both methods. 1-10 ${\mu}$g/mL of ethionamide and thioctic acid could be etermined by the spectrophotometric method with detection limits of 0.11 and 0.089 ${\mu}$g/mL for the two drugs respectively. 2-10 ${\mu}$g/mL of carbocisteine and penicillamine could be determined by the kinetic method with detection limits of 0.14 and 0.21 ${\mu}$g/mL respectively. The two methods were successfully applied for the determination of these drugs in their dosage forms.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

The chemical speciation and analysis of trace elements in sediment with neutron activation analytical method(NAA) and atomic mass spectrometry (중성자 방사화분석법과 원자질량분석법을 이용한 침전물 시료속에 존재하는 미량원소들의 화학종 분류 및 분석)

  • Nam, Sang-Ho;Kim, Jae-Jin;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.358-367
    • /
    • 2003
  • In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will play an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA.

Improvement of Analytical Method for Determination of Germanium in Plant by Atomic Absorption Spectrometry (원자흡광분광법에 의한 식물체 중의 게르마늄 분석법 개선)

  • Han, Seong-Soo;Rim, Yo-Sup;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.179-186
    • /
    • 1997
  • This study was carried out to improve the analytical method for determination of germanium in plants by atomic absorption spectrometry with graphite furnace. For the decomposition of plant samples, the mixed acid of $HNO_3+HClO_4+H_2SO_4$(10 : 4 : 1, v/v) was used. Under this condition, time requirement for the decomposition was 4~5 days and recovery rate was more than 98%. Solution for filling up to constant volume after decomposition was 0.1M acetic acid-sodium acetate. Detection limit for determination of germanium was 0.02 ppm by atomic absorption spectrometry with graphite furnace and argon gas. These results were corresponded with the above-mentioned research projects for improving the determination method of germanium in plants.

  • PDF

Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement (식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정)

  • Park, Sang-Wook;Kim, Hyung Bum;Kim, Kwang Joon;Lee, Wonjae
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

Determination of Selenium and Tellurium by HG-AAS in Foods

  • Cha, Ki-Won;Park, Sang-Ho;Park, Kwang-Won
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.419-425
    • /
    • 1995
  • A method has been investigated for the determination of selenium and tellurium in Ginseng, Ganoderma and Garlic using hydride generation atomic absorption spectrometry(HG-AAS). The concentration effects of hydrochloric acid and sodium tetrahydroborate on the hydride generation for the determination of selenium and tellurium were investigated. The method of sample decomposition was also investigated using various mineral acids, such as nitric, perchloric and sulfuric acid in the closed system, and foreign ion effects containing in the samples were studied. The calibration curves of selenium and tellurium were obtained in the range of 0~40 ppb. The detection limits(S/N=2) of selenium and tellurium are 0.1 and 0.2 ppb. Analytical data of selenium and tellurium in Garlic, Ganoderma and Ginseng are 289, 296 and 198 ng/g for selenium and 146, 127 and 110 ng/g for tellurium, respectively.

  • PDF

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.