• Title/Summary/Keyword: Analytical Method

Search Result 7,621, Processing Time 0.038 seconds

Efficiency Optimal Design of a Brushless DC Motor Considering the Magnetization Direction of Permanent Magnet (영구자석의 착자방향을 고려한 브러시리스DC 전동기의 효율 최적화 설계)

  • Song, Jeong-Hyun;Kim, Byung-Taek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.241-247
    • /
    • 2011
  • This paper is intended to improve efficiency of two-phase BLDC motor using analytical and statistical methods, and then the stability of the starting for the designed model is investigated. The characteristics of the motor according to magnetization directions of permanent magnet are analyzed through the analytical method, and design variables that affect the efficiency are selected. Preliminary optimal design is performed using the analytical method with the design variable. The RSM (Response Surface Method) based on the FEA (Finite Element Analysis) is applied to complement errors of the analytical method. As a result, the optimal design is determined. Finally, the stability of the starting for the optimal designed model is evaluated by analyzing cogging torque, and it is verified through the FEA.

Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement (식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정)

  • Park, Sang-Wook;Kim, Hyung Bum;Kim, Kwang Joon;Lee, Wonjae
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

Eddy-Current Loss Analysis in Rotor of Surface-Mounted Permanent Magnet Machines Using Analytical Method (해석적 방법을 이용한 표면부착형 영구자석 기기의 회전자 와전류 손실해석)

  • Choi, Jang-Young;Choi, Ji-Hwan;Jang, Seok-Myeong;Cho, Han-Wook;Lee, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1115-1122
    • /
    • 2012
  • This paper analyzes eddy-current loss induced in magnets of surface-mounted permanent magnet (SPM) machines by using an analytical method such as a space harmonic method. First, on the basis of a two-dimensional (2D) polar coordinate system and a magnetic vector potential, the analytical solutions for the flux density produced by armature winding current are obtained. By using derived field solutions, the analytical solutions for eddy current density distribution are also obtained. Finally, analytical solutions for eddy current loss induced in rotor magnets are derived by using equivalent electrical resistance calculated from magnet volume and analytical solutions for eddy-current density distribution. In particular, the influence of time harmonics in armature current on the eddy current loss is fully investigated and discussed. All analytical results are validated extensively by finite element analysis (FEA).

Analysis on electromagnetic characteristics of linear induction motor using the analytical method (해석적인 방법에 의한 직선형 유도 전동기의 전자기적 특성해석)

  • Jang, Seok-Myeong;Choi, Ji-Hwan;Ko, Kyoung-Jin;Kim, Hyun-Kyu;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.804_805
    • /
    • 2009
  • This paper deals with analysis on electromagnetic characteristics of linear induction motor(LIM) using the analytical method. As a analytical method, space harmonics method which is applied to multilayer region is used in this paper. Using the flux density obtained by analytical method, thrust and normal force are calculated through Maxell stress tensor. The results such as flux densitty, eddy current and force are verified by comparison between analytical results and FEM.

  • PDF

Theoretical analysis of Y-shape bridge and application

  • Lu, Peng-Zhen;Zhang, Jun-Ping;Zhao, Ren-Da;Huang, Hai-Yun
    • Structural Engineering and Mechanics
    • /
    • v.31 no.2
    • /
    • pp.137-152
    • /
    • 2009
  • Mechanic behavior of Y-shape thin-walled box girder bridge structure is complex, so one can not exactly hold the mechanical behavior of the Y-shape thin-walled box girder bridge structure through general calculation theory and analytical method. To hold the mechanical behavior better, based on elementary beam theory, by increasing the degree of freedom analytical method, taking account of restrained torsiondistortion angledistortion warp and shearing lag effect at the same time, authors obtain a thin-walled box beam analytical element of 10 degrees of freedom of every node, derive stiffness matrix of the element, and code a finite element procedure. In addition, authors combine the obtained procedure with spatial grillage analytical method, meanwhile, they build a new analytical method that is the spatial thin-walled box girder element grillage analysis method. In order to validate the precision of the obtained analysis method, authors analyze a type Y-shape thin-walled box girder bridge structure according to the elementary beam theory analytical method, the shell theory analytical method and the spatial thin-walled box girder element grillage analysis method respectively. At last, authors test a type Y-shape thin-walled box girder bridge structure. Comparisons of the results of theory analysis with the experimental text show that the spatial thin-walled box girder element grillage analysis method is simple and exact. The research results are helpful for the knowledge of the mechanics property of these Y-shape thin-walled box girder bridge structures.

Beat Map Drawing Method of Bell Type Structures and Beat Maps of the King Seong-deok Divine Bell (종형 구조물의 맥놀이 지도 작성법과 성덕대왕신종의 맥놀이 지도)

  • 김석현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.8
    • /
    • pp.626-636
    • /
    • 2003
  • The beat distribution property of the King Seong-deok Divine Bell is investigated by experiment and analysis. The beat map method is proposed to explain the beat distribution property on the circumference of the bell. For the analytical investigation, an analytical model of the vibration beat is derived on a slightly asymmetric shell of revolution by using the modal expansion method. In the analytical method, the beat map can be drawn only if the modal parameters of the bell are obtained. The analytical beat model is applied to draw the beat map of the King Seong-deok Divine Bell. The validity of the analytical method is verified by comparing the analytical beat maps with the experimental results. This paper proposes a visualization method of the beat and theoretically identifies the reason why the clear and unclear beats repeat periodically along the circumference of the bell and how the striking position influences the beat distribution property.

Analysis and Optimization of the Axial Flux Permanent Magnet Synchronous Generator using an Analytical Method

  • Ikram, Junaid;Khan, Nasrullah;Junaid, Qudsia;Khaliq, Salman;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.257-265
    • /
    • 2017
  • This paper presents a 2-D analytical method to calculate the back EMF of the axial flux permanent magnet synchronous generator (AFPMSG) with coreless stator and dual rotor having magnets mounted on both sides of rotor yoke. Furthermore, in order to reduce the no load voltage total harmonics distortion (VTHD), the initial model of the coreless AFPMSG is optimized by using a developed analytical method. Optimization using the 2-D analytical method reduces the optimization time to less than a minute. The back EMF obtained by using the 2-D analytical method is verified by a time stepped 3-D finite element analysis (FEA) for both the initial and optimized model. Finally, the VTHD, output torque and torque ripples of both the initial and optimized models are compared with 3D-FEA. The result shows that the optimized model reduces the VTHD and torque ripples as compared to the initial model. Furthermore, the result also shows that output torque increases as the result of the optimization.

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

Comparative Study on Separation Method of Attenuation Quality Factor (감쇠상수 분리방법의 비교 분석)

  • Chung, Tae-Woong
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.281-288
    • /
    • 2009
  • Using analytical method, intrinsic absorption and scattering attenuation was lately separated from total quality factor $(Q^{-1}_t)$ on the seismic data of Korean Peninsula. However, we should use numerical method rather than the analytical method to consider depth dependent structure of scattering. The direct simulation Monte Carlo (DSMC) method, as a kind of the numerical method, is good option due to its extended availability from 1 to 3-dimensional model; but there is few study to use it. In this paper, we introduced the analytical method and the DSMC method, and compared the results of the two analysis applied to the isotropic scattering model. While the scattering attenuation coefficients $(\eta_s)$ are identical, the intrinsic absorption coefficients $(\eta_i)$ for the analytical method are larger than those for DSMC method and have large errors. In addition, the $(Q^{-1}_t)$ by the previous studies show closer to DSMC method than analytical method.

Development of Analytical Method for Ambroxol Hydrochloride and Clenbuterol Hydrochloride Formulation in Korean Pharmaceutical Codex (고시수재 의약품 중 암브록솔염산염 및 클렌부테롤염산염 함유 제제의 함량 시험법 개선)

  • Lee, Tae-Woong;Jeong, Rae-Seok;Park, Soo-Jin;Choi, Lan;Shim, Young-Hun;Choi, Bo-Kyung;Kwak, Hyo-Sun
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.190-199
    • /
    • 2014
  • The Korean Pharmaceutical Codex (KPC) analytical method of ambroxol hydrochloride and clenbuterol hydrochloride formulation is complicated and needed to carry out multiple processes during the test. To improve the low efficiency of analytical procedure that makes pharmaceutical laboratory consume much time and high cost to conduct the test of this formulation, this study was performed for simplifying the pretreatment process and optimizing conditions of the HPLC assay. The analytical procedure using HPLC was developed to establish analytical specification for ambroxol hydrochloride and clenbuterol hydrochloride formulations. The newly developed analytical method has good linearity ($R^2$ >0.999), specificity, precision (RSD<1.0%) and the recovery ranges of 98.50~101.84% for ambroxol, 98.29~101.35% for clenbuterol syrup and 98.66~101.71% for clenbuterol tablets. The LOQs were 0.204 ${\mu}g/ml$ for ambroxol, 0.021 ${\mu}g/ml$ for clenbuterol syrup and 0.073 ${\mu}g/ml$ for clenbuterol tablets. The new method was performed with commercially available samples to confirm analytical conditions and validated to be suitable for saving time and cost to control the quality of routine manufactured products. This analytical method will be used for revising the monograph of ambroxol hydrochloride and clenbuterol hydrochloride formulation in next supplement of KPC.