• Title/Summary/Keyword: Analysis of Electrical Safety Level

Search Result 85, Processing Time 0.022 seconds

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

Design and Verification of the Hardware Architecture for the Active Seat Belt Control System Compliant to ISO 26262 (ISO 26262에 부합한 능동형 안전벨트 제어 시스템의 하드웨어 아키텍처 설계 및 검증)

  • Lee, Jun Hyok;Koag, Hyun Chul;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2030-2036
    • /
    • 2016
  • This paper presents a hardware development procedure of the ASB(Active Seat Belt) control system to comply with ISO 26262. The ASIL(Automotive Safety Integrity Level) of an ASB system is determined through the HARA(Hazard Analysis and Risk Assessment) and the safety mechanism is applied to meet the reqired ASIL. The hardware architecture of the controller consists of a microcontroller, H-bridge circuits, passive components, and current sensors which are used for the input comparison. The required ASIL for the control systems is shown to be satisfied with the safety mechanism by calculation of the SPFM(Single Point Fault Metric) and the LFM(Latent Fault Metric) for the design circuits.

Railway Software Analysis Tool using Symbolic Execution Method (심볼릭 수행 방법을 이용한 철도 소프트웨어 코드분석 도구제안)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu;Shin, Duck-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.242-249
    • /
    • 2016
  • The railway system is being converted to the computer system from the existing mechanical device, and the dependency on software is being increased rapidly. Though the size and degree of complexity of software for railway system are slower than the development speed of hardware, it is expected that the size will be grown bigger gradually and the degree of complexity will be increased also. Accordingly, the validation of reliability and safety of embedded software for railway system was started to become influential as the important issue. Accordingly, various software test and validation activities are highly recommended in the international standards related railway software. In this paper, we presented a software coding analysis tool using symbolic execution for railway system, and presented its result of implementation.

A Study on Safety Assessment of CTC/EI Interface (열차집중제어장치와 전자연동장치 인터페이스의 안전성평가에 관한 연구)

  • SHIN Seok-kyun;LEE Key-seo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.309-316
    • /
    • 2005
  • In this paper we analyzed a dangerous failure and a safety requirement based on HIA (Hazard Identification and Analysis) of an interface model between CTC (Centralized Traffic Control) system and El (Interlocking) system, and assigned SU (Safety Integrity Level) by way of an risk estimation of the interface, which employed PHA (Preliminary Hazard Analysis) for the interface of the track control system, being managed as separated system between the centralized traffic control system and the interlocking system, An estimation which satisfies a safety reference of the international standard has been achieved through a quantification of the system failure rate and the dangerous failure rate of the interface model.

On the Hazard Identification Methods for the Realization of Functional Safety Standards (기능안전 표준들의 구현을 위한 기능 중심의 위험원 식별 방법)

  • Jung, Ho Jeon;Lee, Jae Chon;Oh, Seong Keun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.105-112
    • /
    • 2013
  • To meet the growing needs from a variety of stakeholders, the development of modern systems is getting more complex and thus, the systems failure in the actual operations can potentially become more serious. This is why several international or military standards on systems safety have been published. In spite of the importance of meeting those standards such as IEC 61508 and ISO 26262 in the systems development, the associated practical methods seem deficient since those standards do not provide them. The objective of this paper is to present a method to identify potential hazards in fulfilling the requirements of the safety standards. In particular, the approach taken here is based on applying the functional analysis that covers several levels of the system under development. Note, however, that in the most of the conventional methods for hazards identification, the analysis has been focused on the failure at or underneath the component level of the system. The hazards identification method in this paper would cover the level up to the system by utilizing the functions-oriented approach. The case study of the safety enhancement for locomotive cabs is also discussed.

A Hazard Identification and Analysis for the Train Control System of Light Rail Transit (경량전철 열차제어시스템의 위험요인 분석)

  • 정의진;김양모
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.2
    • /
    • pp.99-106
    • /
    • 2004
  • Train control system in LRT (Light Rail Transit) is developed as a part of "Light Rail Transit System Development Project". But there was no specific requirement representing the system safety. Because system safety must be ensured before the customization, we applied the system to a officially recognized specific procedure, such as "A Guideline to Ensure the Safety of Train Control System in Korea" that was officially announced by KNR (Korea National Railroad) in 2001. We should draw system safely requirement to guarantee system safety for the first time. In this paper, the hazard identification and analysis to derive the safety requirement on LRT train control system are carried out following the KNR guideline. To analyze hazard, we have to deduce system functions, identify related hazards, derive the effects of the hazards, analyze current risk, define the target risk of the system, and deduce the alternative plans to reduce the effects of the hazards. After the hazard analysis following the upper procedure, 30 hazards are identified and analysed. Especially detailed analysis on train collision that is a main hazard of the train control of system is specially carried out.

A Study on the Functional Safety Analysis of PES-based Electronic Interlocking Unit according to IEC 61508 (IEC 61508 기준 PES 기반 전자연동장치의 기능 안전도 분석에 관한 연구)

  • Lee, Myung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1526-1532
    • /
    • 2014
  • The Electronic Interlocking unit in railway signalling system is safety-related facilities to determine route and speed for train running. In particular, the SSI(Solid State Interlocking) is Electronic Interlocking unit for high-speed railway, and it performs safety-critical function by MPM(Micro-Processor Module). Meanwhile, MPM is composed of the PES(Programmable Electronic System)-based system, and the PES-based system in railway safety-related facilities should be implemented by complying with the safety requirements defined in IEC 62425 and IEC 61508. In this paper, we performed modeling of failure rate and reliability for MPM implemented by fault tolerance methods and analyzed functional safety for MPM. Moreover, we determined SIL(Safety Integrity Level) for MPM according to the safety requirements defined in IEC 61508 based on an analyzed functional safety.

A Study on the Process to Establish Safety of Level Crossing (건널목장치에서의 안전성확보 방안 고찰)

  • Joung, E.J.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.315-317
    • /
    • 2001
  • In this paper, the relationship between system engineering lifecycle and safety lifecycle is investigated. V diagram and IEC 61508 model are represented in the lifecycle model. V diagram easily shows the flow of information between phases. But it does not show the amount of work involved in each stage. IEC 61508 model describes the activities to be performed during each phase of the lifecycle. And also the causal-consequence analysis for the level crossing is presented Representing this analysis procedure, we are try to establish safety of level crossing.

  • PDF

Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet (전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석)

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.