• Title/Summary/Keyword: Analysis of Correlation

Search Result 21,718, Processing Time 0.064 seconds

Edge to Edge Model and Delay Performance Evaluation for Autonomous Driving (자율 주행을 위한 Edge to Edge 모델 및 지연 성능 평가)

  • Cho, Moon Ki;Bae, Kyoung Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.191-207
    • /
    • 2021
  • Up to this day, mobile communications have evolved rapidly over the decades, mainly focusing on speed-up to meet the growing data demands of 2G to 5G. And with the start of the 5G era, efforts are being made to provide such various services to customers, as IoT, V2X, robots, artificial intelligence, augmented virtual reality, and smart cities, which are expected to change the environment of our lives and industries as a whole. In a bid to provide those services, on top of high speed data, reduced latency and reliability are critical for real-time services. Thus, 5G has paved the way for service delivery through maximum speed of 20Gbps, a delay of 1ms, and a connecting device of 106/㎢ In particular, in intelligent traffic control systems and services using various vehicle-based Vehicle to X (V2X), such as traffic control, in addition to high-speed data speed, reduction of delay and reliability for real-time services are very important. 5G communication uses high frequencies of 3.5Ghz and 28Ghz. These high-frequency waves can go with high-speed thanks to their straightness while their short wavelength and small diffraction angle limit their reach to distance and prevent them from penetrating walls, causing restrictions on their use indoors. Therefore, under existing networks it's difficult to overcome these constraints. The underlying centralized SDN also has a limited capability in offering delay-sensitive services because communication with many nodes creates overload in its processing. Basically, SDN, which means a structure that separates signals from the control plane from packets in the data plane, requires control of the delay-related tree structure available in the event of an emergency during autonomous driving. In these scenarios, the network architecture that handles in-vehicle information is a major variable of delay. Since SDNs in general centralized structures are difficult to meet the desired delay level, studies on the optimal size of SDNs for information processing should be conducted. Thus, SDNs need to be separated on a certain scale and construct a new type of network, which can efficiently respond to dynamically changing traffic and provide high-quality, flexible services. Moreover, the structure of these networks is closely related to ultra-low latency, high confidence, and hyper-connectivity and should be based on a new form of split SDN rather than an existing centralized SDN structure, even in the case of the worst condition. And in these SDN structural networks, where automobiles pass through small 5G cells very quickly, the information change cycle, round trip delay (RTD), and the data processing time of SDN are highly correlated with the delay. Of these, RDT is not a significant factor because it has sufficient speed and less than 1 ms of delay, but the information change cycle and data processing time of SDN are factors that greatly affect the delay. Especially, in an emergency of self-driving environment linked to an ITS(Intelligent Traffic System) that requires low latency and high reliability, information should be transmitted and processed very quickly. That is a case in point where delay plays a very sensitive role. In this paper, we study the SDN architecture in emergencies during autonomous driving and conduct analysis through simulation of the correlation with the cell layer in which the vehicle should request relevant information according to the information flow. For simulation: As the Data Rate of 5G is high enough, we can assume the information for neighbor vehicle support to the car without errors. Furthermore, we assumed 5G small cells within 50 ~ 250 m in cell radius, and the maximum speed of the vehicle was considered as a 30km ~ 200 km/hour in order to examine the network architecture to minimize the delay.

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (III) (미세균열의 간격 분포를 이용한 결의 평가 (III))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.311-324
    • /
    • 2016
  • The characteristics of the rock cleavage in Jurassic granite from Geochang were analysed. The evaluation for three quarrying planes and three rock cleavages was performed using the parameters such as (1) reduction ratio between the value of spacing and the value of length, (2) microcrack spacing frequency(N), (3) total spacing($1mm{\geq}$), (4) exponential constant(a), (5) magnitude of exponent(${\lambda}$), (6) mean spacing($S_{mean}$), (7) difference value($S_{mean}-S_{median}$) between mean spacing and median spacing($S_{median}$) and (8) density of spacing. Especially the close dependence between the above spacing parameters and the parameters from the spacing-cumulative frequency diagrams was derived. The discrimination factors representing three quarrying planes and three rock cleavages were acquired through these mutual contrast. The analysis results of the research are summarized as follows. First, the reduction ratios of frequency(N), mean value, median value, the above difference value($S_{mean}-S_{median}$) and density for three rock cleavages are in orders of G(grain, (G1 + G2)/2) < H(hardway, (H1 + H2)/2) < R(rift, (R1 + R2)/2), H < G $\ll$ R, H < G $\ll$ R, H < G < R and H < G $\ll$ R. The values of the above five parameters for three planes show the various orders of R'(rift plane) $\ll$ H'(hardway plane) < G'(grain plane), R' $\ll$ G' < H', R' < H' < G', R' < G' < H' and R' $\ll$ H' < G', respectively. Second, the values of (I) parameters(2, 3, 4 and 5) and (II) parameters(6, 7 and 8) are in orders of (I) H < G < R and (II) R < G < H. On the contrary, the values of the above two groups(I~II) of parameters for three planes show reverse orders. Third, to review the overall characteristics of the arrangement among the six diagrams, these diagrams show an order of R2 < R1 < G2 < G1 < H2 < H1 from the related chart. In other words, above six diagrams can be summarized in order of rift(R1 + R2) < grain(G1 + G2) < hardway(H1 + H2). These results indicate a relative magnitude of rock cleavage related to microcrack spacing. Especially, two parameters for each diagram, the above difference value($S_{mean}-S_{median}$) and mean spacing, could provide advanced information for prediction the order of arrangement among the diagrams. Finally, the general chart for three planes and three rock cleavages were made. From the related chart, three exponential straight lines for three rock cleavages show an order of R(R1 + R2) < G(G1 + G2) < H(H1 + H2). On the contrary, three lines for three planes show an order of H'(R2 + G2) < G'(R1 + H2) < R'(G1 + H1). Consequently, correlation of the mutually reverse order between three planes and three rock cleavages can be drawn from the related chart.

An influence of operator's posture on the shape of prepared tooth surfaces for fixed partial denture (진료자세가 고정성 국소의치의 지대치 삭제에 미치는 영향)

  • Won, In-Jae;Kwon, Kung-Rock;Pae, Ah-Ran;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.38-48
    • /
    • 2011
  • Purpose: Dentists suffer back, neck and shoulder pain during their careers due to bad operating posture. If dentists have a good operating posture ergonomically, there would be less pain and discomfort in the shoulder and back. Therefore, dentists should learn the Home position which enables dentists to approach a stable posture ergonomically. This study was to compare tooth preparation in the Home position and the Random position, and evaluate the clinical efficacy of the Home position. Materials and methods: Tooth preparation for fixed partial denture was performed on the maxillary left 2nd premolar and maxillary left 2nd molar at the two different operating positions were compared. The amount of occlusal reduction, marginal width, subgingival margin depth, and convergence angle were measured. A T-test was performed separately to compare the results of the Random position and the Home position. Results: 1. The amounts of average thickness of occlusal reduction on fossa were deficient to the ordered ones in the Random position and the Home position (P > .05). 2. The average subgingival margin depth of prepared margin on maxillary left 2nd premolar, maxillary left 2nd molar were excessive in the Random position than in the Home position. On the maxillary left 2nd premolar, there was no statistical difference in the Random position and the Home position except Distal midline, DL line angle, Lingual midline, ML line angle (P< .05). On the maxillary left 2nd molar, there was no statistical difference in the Random position and the Home position (P < .05). 3. Average convergence angle in the Random position and the Home position were excessive compared to the ordered angle. There was no statistical difference in the Random position and the Home position (P > .05). 4. Analysis of pearson correlation : In the Random position, the amounts of average thickness of occlusal reduction, the average subgingival margin depth of prepared margin, convergence angle were significantly associated with each other (P < .05). But in the Home position, they were not significantly associated with each other (P < .05). 5. The time needed for preparation in the Home position was faster or equal than that of the Random position as time went on. Conclusion: In conclusion, there were no significant differences between Home position and Random position in measures of occlusal reduction, marginal width, marginal depth, convergence angle. However, preparation time and incidence of damaging adjacent teeth were less in Home position than in Random position. Therefore, if trained properly, Home position which is more ergonomically stable can be adopted for clinical use.

The Difference between Career Barrier Recognition and Career Preparation Behavior by Mandatory military service Planning Level among Male College Students (남자대학생의 군 의무복무계획 수준에 따른 진로장벽인식과 진로준비행동의 차이)

  • Hong, Hye-Young;Kang, Hye-Young
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.218-239
    • /
    • 2013
  • This study aims to understand the status of mandatory military service planning and career barrier recognition as well as to analyze the difference between how students perceive mandatory military service as a potential barrier to their future careers(career barrier recognition) and career preparation behavior by the mandatory military service planning level among male college students. For the purpose, inquiries for the subject were set up as follows. 1. What are the levels of mandatory military service planning and career barrier recognition? 2. Is there a difference in career barrier recognition depending on the level of mandatory military service planning? 3. Is there a difference in career preparation behaviour depending on the level of mandatory military service planning? This study found out the level of mandatory military service, military barrier recognition and career preparation behavior of 284 male students from 4 universities in Daejeon and Chungnam area. Along with that, descriptive statistic, correlation analysis and t-test were conducted with SPSS 17.0 program The results of this study are as follows: First, 79.2% of male students have higher mandatory military service planning than the average value. Meanwhile, considering 3 sub-factors of mandatory military service planning, the ratio of those with high scores in practicality is lower than importance and concreteness. Based on this, it is assumable that they have a low perception for practical and concrete behaviors such as data collection in mandatory military service planning, which indicates their awareness has not developed into concrete behaviors even though they recognize the importance of planning. Also 73.9% of male students responded higher career barrier recognition than the average value shows that they recognize mandatory military service as a barrier relatively highly. Especially, those who answered "Very much" (7 scores) for every inquiry in career barrier recognition accounted for 16.9%, which forms the biggest group. and considering the response by each inquiry, it is ascertained that they consider the absence by mandatory military service time or military service as the biggest difficulty. Second, the difference in career barrier recognition between the top 30% and bottom 30% of mandatory military service planning is not statistically significant. However, in terms of importance and the sub-factor of mandatory military service planning, a significant inter-group difference in career barrier recognition is shown. In other words, to join the military is recognized as an obstacle in their career barrier recognition regardless of the mandatory military service planning level. Also, a group which considers the importance of the mandatory military service planning highly recognizes the military as the bigger obstacle compared to the other groups which are not considered in this way. Third, the difference in career barrier recognition between the top 30% and the bottom 30% of the mandatory military service planning is statistically significant. The need of mandatory military service planning is marked by the fact that those with a high level of mandatory military service planning show stronger career barrier recognition than those without plans. Through the study, the need of mandatory military service planning is suggested to both male students and career consultants considering the mandatory military service from a perspective of career based on Korean reality. Also, as precedent studies on pre-inducted men can be hardly found currently, this study is significant in accumulating empirical data about mandatory military service, a unique characteristic of the Korean career development process.

The Evaluation of IL-8 in the Serum of Pneumoconiotic patients (진폐증 환자에서의 혈청내 IL-8 농도)

  • Ahn, Hyeong Sook;Kim, Ji Hong;Chang, Hwang Sin;Kim, Kyung Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.945-953
    • /
    • 1996
  • Background : Many acute and chronic lung diseases including pneumoconiosis are characterized by the presence of increased numbers of activated macrophages. These macrophages generate several inflammatory cell chemoattractants, by which neutrophil migrate from vascular compartment to the alveolar space. Recruited neutrophils secrete toxic oxygen radicals or proteolytic enzymes and induce inflammatory response. Continuing inflammatory response results in alteration of the pulmonary structure and irreversible fibrosis. Recently, a polypeptide with specific neutrophil chemotactic activity, interleukin-8(IL-8), has been cloned and isolated from a number of cells including : monocytes, macrophages and fibroblasts. IL-1 and/or TNF-${\alpha}$ preceded for the synthesis of IL-8, and we already observed high level of IL-1 and TNF-${\alpha}$ in the pneumoconioses. So we hypothesized that IL-8 may be a central role in the pathogenesis of pneumoconiosis. In order to evaluate the clinical utility of IL-8 as a biomarker in the early diagnosis of pneumoconiosis, we investigated the increase of IL-8 in the pneumoconiotic patient and the correlation between IL-8 level and progression of pneumoconiosis. Method : We measured IL-8 in the serum of 48 patients with pneumoconiosis and 16 persons without dust exposure history as a control group. Pneumoconiotic cases were divided into 3 groups according to ILO Classification : suspicious group(n=16), small opacity group(n=16) and large opacity group(n=16). IL-8 was measured by a sandwich enzytne immunoassay technique. All data were expressed as the $mean{\pm}standard$ deviation. Results: 1) The mean value of age was higher in the small opacity and large opacity group than comparison group, but smoking history was even. Duration of dust exposure was not different among 3 pneumoconiosis groups. 2) IL-8 level was $70.50{\pm}53.63pg/m{\ell}$ in the suspicious group, $107.50{\pm}45.88pg/m{\ell}$ in the small opacity group, $132.50{\pm}73.47pg/m{\ell}$ in the large opacity group and $17.85{\pm}33.85pg/m{\ell}$ in the comparison group. IL-8 concentration in all pneumoconiosis group was significant higher than that in the comparison group(p<0.001). 3) IL-8 level tended to increase with the progression of pneumoconiosis. Multiple comparison test using Anova/Scheffe analysis showed a significant difference between suspicious group and large opacity group(p<0.05). 4) The level of IL-8 was correlated with the progression of pneumoconiosis(r=0.4199, p<0.05). Conclusion : IL-8 is thought to be a good biomarker for the early diagnosis of pneumoconiosis.

  • PDF

The Development of the Korean Evaluation Scale for Hearing Handicap (KESHH) for the Geriatric Hearing Los (노인성난청을 위한 청각장애평가지수(KESHH)의 개발)

  • Ku, Ho-Lim;Kim, Jin-Sook
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.973-992
    • /
    • 2010
  • The hearing impairment is the representative disorder that affects the quality of the routine life of the aged period. This study was aimed to develop the Korean evaluation scale for hearing handicap(KESHH) with which we can evaluate social and psychological effects of the hearing impairment. Applying this scale clinically, we can analyze the geriatric hearing loss specifically and improve the quality of the aural rehabilitation that can help the hardness of the hearing impairment. Data were collected from 288 participants(176 hearing aid users and 112 non-hearing aid users) and the average age of the participants was 67.4 years old ( 60.15 for the hearing aids users and 78.9 for the non hearing users). The composition ratio of the male and female participants were 58.0% and 42.0% and extrovert and introvert personality were 49.3% and 50.7% showing balanced formation. The tentative draft of KESHH measurements were produced with 30 items and following 5 subscales. Using factor analysis, 6 items were erased and 4 subscales - social effect, psycho/emotional effect, interpersonal effect, and perception of hearing aids - were identified. As each subscale consisted of 6 items, 24 items were corrected and remained totally. Conclusively, the KESHH was developed with 24 items and 4 subscales including 6 items on each subscale. In addition, the KESHH was divided into type-1 and 2 depending on hearing aid users and non hearing aid users. The results of this study can be summarized as the following 5 parts. Firstly, the reliabilities of the KESHH were proved to be high because the subscales' Cronbach alpha values were from 0.723 through 0.895. Secondly, the KESHH showed systematically increasing score as the hearing impairment increased. The lowest score was 24 and the highest score was 117 and the average scores of the hearing impaired and non-hearing impaired are 72.06(SD=15.67) and 66.98(SD=20.94) showing 5.08 increased score for the hearing impaired. Depending on the degree of the hearing loss, the scores recorded 52.63 at the below of the mild hearing loss, 67.29 for the moderate hearing loss, 71.89 for the moderately severe hearing loss, and 75.57 for the severe hearing loss The comparison of the scores by hearing levels indicated that the higher the hearing levels were, the higher the scores of the KESHH with statistical significance(p<0.001). Thirdly, the correlation among 4 subscales was 0.384~0.880(p<0.001). Also, the pure tone average, personality, and the four subscales correlations showed statistical significance with 0.148~0.880 except for the pure tone average and personality and the pure tone average and perception of hearing aids. Fourthly, the total variances explained for the independent subscles were analyzed with multiple regression. The social effect was explained 17.4% with pure tone average, personality, and the status of hearing aid use variances. The psycho/emotional effect was explained 14.4% with puretone average, personality, and age variances. The interpersonal effect was explained 11.2% with pure tone average, personality, and the status of hearing aid use variances. The perception of hearing aids effect was explained 2.2% with only personality. Finally, test-retest reliability was proved to be high with 0.791(p<0.001). Conclusively, the KESHH that was developed considering Korean culture can be a useful instrument for expressing the hearing handicaps of the Korean aged hearing impaired in scores for both hearing aid users and non-users. Also, it is thought that the KESHH is useful clinically for identifying the changes of the hearing handicap scores before and after wearing hearing aids and aural rehabilitation at diverse situations.

A survey of foodservice satisfaction and menu preference of high school boarding students in Jeju (제주지역 고등학생의 기숙사급식 만족도 및 급식메뉴 기호도 조사)

  • Kim, Kyung-Ja;Chae, In-Sook
    • Journal of Nutrition and Health
    • /
    • v.47 no.1
    • /
    • pp.77-88
    • /
    • 2014
  • Purpose: This study analyzed the foodservice satisfaction and menu preference of 506 high school boarding students in Jeju surveyed from July 2-30, 2012 with the aim of providing basic data for improving the quality of boarding food-service management. Methods: The data were analyzed using descriptive analysis, t-test, and Pearson's correlation coefficients, using the SPSS Win program (version 12.0). Results: Regarding satisfaction with dormitory foodservice, the satisfaction scores for service and hygiene were 3.46 (out of 5 scales), whereas the score for menu quality was 3.26 points. In terms of satisfaction by meal, dinner showed the highest score, at 3.70 (out of 5 scales). The satisfaction scores for breakfast were significantly higher in girls (3.36) than boys (2.93). Regarding intake of meals provided, dinner showed the highest score, at 3.96 (out of 5 scales), whereas breakfast showed the lowest score, at 3.63 points. Intake of lunch and dinner was significantly higher in boys (4.12, 4.17, respectively) than girls (3.72, 3.76, respectively). Regarding the requirements of subjects for dormitory foodservice, 43.4% of subjects selected improvement of food taste and 36.6% of girls chose menu diversity. In terms of menu preferences for main dishes, the students preferred noodles (4.06) and one-dish cooked rice (3.92) to cooked rice (3.66). The subjects preferred beef rib soup (4.10) and Kimchi stew (3.99) in soups and stews. With regard to the menu preferences for side dishes, steamed foods showed the highest score, at 3.95 (out of 5 scales), whereas seasoned foods showed the lowest score, at 2.89 points. The students preferred beef, pork, and chicken to fish and vegetables. The students preferred dessert the most with fruit juices (4.52). Bread and rice cake were more favored by girls, showing significant differences between boys and girls (p < 0.05, p < 0.01, respectively). Conclusion: Development of a systematic nutrition education program that can encourage practice of proper eating habits is needed. In addition improvement of the quality of boarding school meals through the service of various menus is needed.

Clinical Analysis of Arteriovenous Fistula in Chronic Renal Failure Patients (만성 신부전 환자에서의 동정맥루 조성술의 임상고찰)

  • Song Chang-Min;Ahn Jae-Bum;Kim In-Sub;Kim Woo-Sik;Shin Yong-Chul;Yoo Hwan-Kuk;Kim Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.39 no.9 s.266
    • /
    • pp.692-698
    • /
    • 2006
  • Background: Owing to the fact that the average life span has increased and the progress in medical science has been made, the number of patients with chronic renal failure (CRF) who have to take hemodialysis (HD) has been going up gradually. Accordingly, it is considered to be as a significant issue to obtain blood vessels which can be used repetitively and supply enough blood flows. Therefore, there have been various kinds of study on an inosculation rate andfactors influencing it following an arteriovenous fistula (AV fistula) and lots of studies are ongoing for the purpose of escalating the inosculation rate. The authors analyzed the effects of short-term result, age, sex, diabetes and hypertension on arteriovenous inosculations in 134 anatomical snuffbox operated subjects among the patients who have taken an AV fistula at this center. Material and Method: Based on 134 patients who underwent an AV fistula at the department of thoracic surgery of this center from July, 2000 to May, 2004, the difference in arteriovenous inosculation rate was compared and analyzed depending or age (discriminated by 65-year-old), sex and the condition of the presence or absence of diabetes and hypertension. Correlation analyses were conducted for each parameter and statistical tests were performed by using SPSS for windows Release 11.0.1, which were determined to be statistically significant if p value was below 0.05. Result: The total number of operations was 169 including 35 of re-operations. The male/female rate was 70 : 64 (52% : 48%). The average age was $56.3{\pm}12.26$ years and there were 33 (24%) old aged patients above 65-year-old; there were 103 (71%) patients with hypertension and 90 (67%) patients with diabetes. Overall arteriovenous inosculation rate was $93{\pm}2.4%,\;91{\pm}2.7%,\;89{\pm}3.0%$ at 6, 12, 24 months, respectively. The arteriovenous inosculation rate of above 65-year-old patient group was $85{\pm}4.8%,\;80{\pm}5.8%,\;80{\pm}5.8%$ and below 64-year-old patient group's was $85{\pm}4.8%,\;80{\pm}5.8%,\;80{\pm}5.8%$ at given time points, respectively, which showed higher inosculation rate in below 64-year-old patient group with a statistical significance (p=0.0034). However, no statistical significance was found between the patients with hypertension and diabetes and the patients with no complication. In addition, there was no statistical significance in inosculation rate between male and female. Conclusion: The arteriovenous inosculation ratewas higher in the treated patient below 64-year-old than in the treated patient above 65-year-old. Thus it is advantageous for increase in long-term inosculation rate to obtain hemodialysis routes at an early age. The conditions of sex and the presence or absence of diabetes and hyper- tension do not make statistically significant effect on the arteriovenous inosculation rate.

NO2 and SO2 Reduction Capacities and Their Relation to Leaf Physiological and Morphological Traits in Ten Landscaping Tree Species (조경수 10개 수종에 있어 NO2, SO2 저감 능력과 잎의 생리적, 형태적 특성과의 관계)

  • Kim, Kunhyo;Jeon, Jihyeon;Yun, Chan Ju;Kim, Tae Kyung;Hong, Jeonghyun;Jeon, Gi-Seong;Kim, Hyun Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.393-405
    • /
    • 2021
  • With increasing anthropogenic emission sources, air pollutants are emerging as a severe environmental problem worldwide. Accordingly, the importance of landscape trees is emerging as a potential solution to reduce air pollutants, especially in urban areas. This study quantified and compared NO2 and SO2 reduction abilities of ten major landscape tree species and analyzed the relationship between reduction ability and physiological and morphological characteristics. The results showed NO2 reduction per leaf area was greatest in Cornus officinalis (19.81 ± 3.84 ng cm-2 hr-1) and lowest in Pinus strobus (1.51 ± 0.81 ng cm-2 hr-1). In addition, NO2 reduction by broadleaf species (14.72 ± 1.32 ng cm-2 hr-1) was 3.1-times greater than needleleaf species (4.68 ± 1.26 ng cm-2hr-1; P < 0.001). Further, SO2 reduction per leaf area was greatest in Zelkova serrata (70.04 ± 7.74 ng cm-2 hr-1) and lowest in Pinus strobus (4.79 ± 1.02 ng cm-2 hr-1). Similarly, SO2 reduction by broadleaf species (44.21 ± 5.01 ng cm-2 hr-1) was 3.9-times greater than needleleaf species (11.47 ± 3.03 ng cm-2 hr-1; P < 0.001). Correlation analysis revealed differences in NO2 reduction was best explained by chlorophyll b content (R2 = 0.671, P = 0.003) and SO2 reduction was best described by SLA and length of margin per leaf area (R2 = 0.456, P = 0.032 and R2 = 0.437, P = 0.001, R2 = 0.872, P < 0.001, respectively). In summary, the ability of trees to reduce air pollutants was related to photosynthesis, evapotranspiration, stomatal conductance, and leaf thickness. These findings highlight effective reduction of air pollutants by landscaping trees requires comprehensively analyzing physiological and morphological species characteristics.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF