• 제목/요약/키워드: Anaerobic sludge

검색결과 514건 처리시간 0.031초

생물학적 하·폐수처리 공정에서 생물촉진제 첨가의 영향 (Effects of Bio-stimulant Addition on Biological Wastewater Treatment Processes)

  • 이석헌;정진영;박기영
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.398-402
    • /
    • 2005
  • The enzyme Xeronine was investigated as a microbial activating substance in biological wastewater treatment processes. Xeronine as bio-stimulant was injected in the anaerobic sludge and the activated sludge treating wastewater in order to examine the effect of hidden benefits. Bio-stimulant did not show significant improvement of anaerobic treatablity. In the aerobic system, higher bio-stimulant dose condition resulted in slightly more removal of nitrogen and phosphorus. Floc aggregation and zone settling velocity as solid-liquid separation factors in activated sludge systems was enhanced by bio-stimulant. Effects of bio-stimulants injection on improvement of water quality and microbial activity did not clear in terms of normal operation conditions.

슬러지 호기성 소화공정에서의 유기물 분해 및 질산화 특성 (Organic Matter Degradation and Nitrification Characteristics in Aerobic Digestion of Sewage Sludge)

  • 황응주
    • 대한환경공학회지
    • /
    • 제31권10호
    • /
    • pp.865-872
    • /
    • 2009
  • 슬러지의 감량과 최종처분 기술 개발을 위해 실험실 규모 호기성 소화공정을 279일간 운전하였다. 혐기성 소화 슬러지를 원료로 $40^{\circ}C$에서 120분간 알칼리 전처리하여 호기성 소화조에 유입시켰다. 유입 슬러지 성상과 HRT의 변화에 따라 소화효율의 변화가 있었으며 적정 HRT는 6일인 것으로 나타났다. 이때 $NH_3$-N, SCOD, TKN, TCOD, SS, VSS의 평균 제거율(소화조 유입 슬러지 기준)은 각각 97.4%, 81.7%, 68.7%, 61.4%, 50.6%, 47.0% 이었다. SS는 전처리와 호기성 소화를 통해 원료 슬러지(23,920 mg/L)의 73.9% 감량화가 가능하였다. 처리 슬러지는 약 350 mg/L의 SCOD를 포함하고 있어 액비로 활용하기에 무리가 없을 것으로 판단되었다. HRT를 5일 이상으로 유지할 경우 질산화 반응이 활성화되었으며 최대 658 mg/L의 유출 슬러지 질산성 질소 농도를 얻을 수 있었다. 암모니아성 질소 농도는 20 mg/L 내외로 크게 감소하였다.

복합 전처리를 통한 하수슬러지의 가용화 및 생물학적 유용성에 관한 연구 (A study for Solubilization and Bioavailability of Sewage Sludge Using the Complex Pre-treatment)

  • 강정현;이희수;이태진
    • 유기물자원화
    • /
    • 제19권3호
    • /
    • pp.35-43
    • /
    • 2011
  • 본 연구에서는 하수슬러지를 전처리 과정을 통해 가용화한 후 혐기성 생물학적 분해를 실시하였다. 산 또는 알칼리 조건과 초음파처리를 복합적으로 적용하여 전처리 후 슬러지의 가용화율을 비교하였으며 알칼리 조건에서 초음파처리를 병행하였을 때 최대 가용화율을 얻을 수 있었다. 가용화된 슬러지의 생물학적 유용성은 복합전처리를 실시한 경우 빠른 생물학적 분해와 더불어 총 가스 발생량은 10배 이상 증가하였으며 가용화된 슬러지에서 바이오가스 생산 가능성을 확인 하였다. 전처리를 실시한 슬러지를 이용하여 생물학적 분해를 실시하였을 때 약 50%정도 높은 수소생성율의 지표가 되는 B/A비를 확인할 수 있었으나 수소생성에 저해가 되는 lactic acid와 propionic acid가 검출되는 것으로 보아 후속연구가 필요할 것으로 판단되었다.

혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가 (Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation)

  • Hur, Joon-Moo;Park, Jong-An
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.77-85
    • /
    • 2002
  • 중온과 고온의 혐기성 연속회분식 공정(anaerobic sequencing batch reactor ; ASBR)에서 소화슬러지의 고액분리특성이 처리효율에 미치는 영향을 규명하고자 하였다. 연구결과 침전가능 고형물농도가 높은 도시하수슬러지 처리시 고액분리특성 및 고액분리형태가 전체처리의 안정성 및 처리효율에 상당한 영향을 미쳤다. 중온ASBR에서는 부상농축현상이 일어났으나, 고온ASBR에서는 중력농축에 의한 고액분리가 일어났으며, 상대적으로 고온 ASBR의 처리효율이 우수하였다. 그리고 수리학적 체류시간, cycle period 및 고액분리형태는 소화슬러지의 농축 특성과 임계 고형물농축을 지배하는 중요한 인자였다. 중온ASBR에서 고액분리 후 농축슬러지베드용적(thickened sludge bed volume)은 매우 중요한 운전 요소이며, 소화슬러지의 중력농축특성은 배출시 농축고형물의 유실현상과 침전시 계속적으로 발생하는 소화가스에 의한 슬러지계면의 파괴현상 및 슬러지베드의 불안전성을 야기시켜 처리효율을 감소시켰다. 중력농축의 경우 소화가스와 슬러지농축용적간의 상호작용(cyclic mutual effect)이 주기적으로 일어났으나, 부상농축에서는 이러한 현상이 일어나지 않았다.

혐기-호기 공정을 이용한 염료페수의 생물학적 처리 (Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System)

  • 박영식;문정현;안갑환
    • 한국환경과학회지
    • /
    • 제11권6호
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

단상 고온 및 중온 혐기성 하수 슬러지의 소화 공정 비교 (Comparison of Single-stage Thermophilic and Mesophilic Anaerobic Sewage Sludge Digestion)

  • 장현민;최석순;하정협
    • 공업화학
    • /
    • 제27권5호
    • /
    • pp.532-536
    • /
    • 2016
  • 본 연구에서는 하수 슬러지를 대상으로 단상 고온($55^{\circ}C$)과 중온($35^{\circ}C$) 혐기성 소화조의 안정성, 고형물 제거 및 메탄생성을 관찰하였다. 실험 결과 별도의 pH 조절 없이 고온($R_{TAD}$, reactor of thermophilic anaerobic digestion) 및 중온 ($R_{MAD}$, reactor of mesophilic anaerobic digestion) 소화조 내 pH의 경우 혐기 소화 시 안정적인 미생물 활성을 나타낸다고 알려진 6.5-8.0 사이의 값을 소화 기간 내내 유지하는 것을 관찰할 수 있었다. 또한, total alkalinity (TA)의 경우 $R_{TAD}$$R_{MAD}$ 모두 3-4 g $CaCO_3/L$의 높은 값을 안정적으로 유지하였다. 고형물 제거의 경우 순응 기간 후 $R_{TAD}$에서 43.3%, $R_{MAD}$에서 33.6%의 VS 제거율을 보이며 $R_{TAD}$에서 약 10% 높은 VS 제거율은 제거율을 보였다. 유기산의 경우 $R_{TAD}$$R_{MAD}$에서 순응 기간 직후 검출되지 않았다. $R_{TAD}$$R_{MAD}$ 모두 순응 기간 후 안정적인 메탄 생성을 보였으며, $R_{TAD}$에서 $R_{MAD}$에 비해 31.4% 향상된 메탄 생성률이 관찰되었다($R_{TAD}$; 243 mL $CH_4/L/d$; $R_{MAD}$ : 185 mL $CH_4/L/d$). 반면, 두소화조 $R_{TAD}$$R_{MAD}$에서의 메탄 수율은 유사한 값을 보였다.

Quantitative Study of the Reformation of Excess Sludge by Intense Aeration Under Nutrient-poor Conditions

  • L Guang Wei;Chen Liming;Toda Kiyoshi;Zhang Shuting
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.519-522
    • /
    • 2004
  • In the course of anaerobic storage of excess sludge, odors due to chemicals such as hydrogen sulfide are produced. These odors cause many problems. Many methods have been developed to eliminate odors, but all current methods are not only costly, but also largely inef­fective. In this paper, we investigate the process of transformation of sludge microorganism cul­tures through intense aeration under nutrient-poor conditions, in terms of the selective adjust­ment and control of microorganism culture. The aerated sludge is subsequently returned to the adjusting pool, where the microorganisms inhibit odors, thus the excess sludge itself will act as an odor inhibitor. The process can be verified in terms of viability, in that the degradation capac­ity of the sludge was maintained after the intensely-aerated sludge was returned to the treat­ment system.

무기슬러지 분리와 슬러지 가용화를 적용한 고효율 호기성 소화기술(CaviTec II)에 의한 슬러지 감량 및 반수류 부하 저감 (Reduction of sludge production and recycled nutrients loading by high-rate aerobic digestion(CaviTec II) with inorganic sludge separation and sludge solubilization)

  • 이동우;배강형;조건상;김성홍
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.411-417
    • /
    • 2014
  • The performance of the new aerobic digestion system combined with inorganic sludge separation unit and sludge solubilization unit, CaviTec II, is evaluated. Anaerobic digester effluent sludge is used for feed sludge of CaviTec II system. By addition of CaviTec II, the amount of cake generated is reduced by 27%, and the soluble nitrogen is reduced by 92%.

ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향 (Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

이상 혐기성 소화 공정을 통한 슬러지 발생량 저감과 바이오가스 생산에 관한 연구 (A Study on the Sludge Reduction and Biogas Production through a Two-phase Anaerobic Digestion Process)

  • 우미희;한기봉
    • 대한환경공학회지
    • /
    • 제32권9호
    • /
    • pp.894-899
    • /
    • 2010
  • 슬러지 감량 효율을 높이기 위해 오존전처리와 고 액분리조를 이용한 이상 혐기성 소화 공정 통해 다음과 같은 결과를 얻었다. 오존전처리를 통한 슬러지의 고형물 농도는 평균 TSS $8.3{\pm}2.0%$, VSS $9.2{\pm}2.8%$의 감소율을 나타내었다. 유기물 농도인 TCOD는 평균 $5.1{\pm}2.4%$ 감소하는 반면 SCOD는 평균 $72.0{\pm}6.5%$ 증가하였는데, 이는 오존으로 인해 세포내의 고분자 유기물이 용출되어 가용화되었기 때문이다. 이상 혐기성 소화 공정의 반응조별 소화가 진행됨에 따라 평균 TSS $21.5{\pm}3.4%$, VSS $20.2{\pm}8.4%$, TCOD $32.1{\pm}7.9%$, SCOD $22.1{\pm}7.2%$의 농도가 감소하였다. 최대 메탄생성량은 177.6 mL $CH_4/g$ TSS, 210.8 mL $CH_4/g$ VSS, 127.0 mL $CH_4/g$ TCOD, 1452.0 mL $CH_4/g$ SCOD이었다. 이상 혐기성 소화와 MLE 하수처리 공정의 연계처리 후 고형물 물질수지 결과 TSS 93.8%, VSS 92.0%의 감소율을 보였다. 이상 혐기성 소화 공정은 슬러지 처리 문제 해결과 신 재생에너지인 바이오가스 회수의 가능성을 보여줌으로서 향후 슬러지 감량에 해결책이 될 수 있을 것으로 사료된다.