• 제목/요약/키워드: Anaerobic fixed-bed

검색결과 14건 처리시간 0.021초

혐기-호기 공정을 이용한 염료페수의 생물학적 처리 (Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System)

  • 박영식;문정현;안갑환
    • 한국환경과학회지
    • /
    • 제11권6호
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

혐기성 슬러지 공정과 호기성 고정생물막 공정을 이용한 염색폐수 처리 (Treatment of Textile Wastewater by Anaerobic Sludge and Aerobic Fixed-Bed Biofilm Reactor)

  • 박영식;문정현
    • 한국환경보건학회지
    • /
    • 제28권3호
    • /
    • pp.55-63
    • /
    • 2002
  • This study was carried out to treat textile wastewater using anaerobic sludge and aerobic fixed-bed biofilm reactor immobilized with Bacillus sp. dominated activated sludge(Bacillus sp. fraction : 81.5%). The range of influent con-centration of SCOD and soluble color were 1032-1507 mg/1, and 1239-1854 degree, respectively. Continuous treatment experiments were performed with variation of textile wastewater ratio at a same HRT. When textile wastewater ratio was 100%(HRT : 24 hours), The removal efficiency of SCOD and soluble color were 88% and 78%, respectively. When compare aerobic reactor of this study that was immobilized with Bacillus sp. dominated activated sludge to other study that was immobilized with activated sludge, SCOD and soluble color removal efficiency of this study showed a little higher efficiency than immobilized with activated sludge. The Bacillus sp. fraction of initial condition was 81.5%), but the fraction after operation was decreased to 31.8%).

Pilot 혐기-호기 공정을 이용한 염색폐수의 생물학적 처리 (Biological Treatment of Textile Wastewater by Anaerobic-Aerobic Reactor System)

  • 박영식;안갑환
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.11-20
    • /
    • 2001
  • An anaerobic sludge-aerobic fixed-bed biofilm(packed with ceramic support carrier of 1 inch size) reactor system was built up to treat textile wastewater. The efficiency of reactor system was examined by determining the effects of textile wastewater ratio(from 25% to 100% at HRT 24 h). The influent range of SCOD concentration and color were 1,036~1,357 mg/L, and 1,487~1,853 degree, respectively. When textile wastewater ratio was 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% and the removal efficiency of the whole system were 75.8%. Color removal efficiency by the anaerobic stage were 45.4%(soluble color), and the removal efficiency of the whole system were 70.2%. In the A/A reactor system, the aerobic stage played an important role in removing both color and COD as well as anaerobic stage.

  • PDF

Dechlorination of High Concentrations of Tetrachloroethylene Using a Fixed-bed Reactor

  • Chang, Young-C.;Park, Chan-Koo;Jung, Kweon;Kikuchi, Shintaro
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.323-336
    • /
    • 2010
  • We evaluated the properties of a fixed-bed column reactor for high-concentration tetrachloroethylene (PCE) removal. The anaerobic bacterium Clostridium bifermentans DPH-1 was able to dechlorinate PCE to cis-1,2-dichloroethylene (cDCE) via trichloroethylene (TCE) at high rates in the monoculture biofilm of an upflow fixed-bed column reactor. The first-order reaction rate of C. bifermentans DPH-1 was relatively high at $0.006\;mg\;protein^{-1}{\cdot}l{\cdot}h^{-1}$, and comparable to rates obtained by others. When we gradually raised the influent PCE concentration from $30\;{\mu}M$ to $905\;{\mu}M$, the degree of PCE dechlorination rose to over 99% during the operation period of 2,000 h. In order to maintain efficiency of transformation of PCE in this reactor system, more than 6 h hydraulic retention time (HRT) is required. The maximum volumetric dechlorination rate of PCE was determined to be $1,100\;{\mu}mol{\cdot}d^{-1}l$ of reactor $volume^{-1}$, which is relatively high compared to rates reported previously. The results of this study indicate that the PCE removal performance of this fixed-bed reactor immobilized mono-culture is comparable to that of a fixed-bed reactor mixture culture system. Furthermore, our system has the major advantage of a rapid (5 days) start-up time for the reactor. The flow characteristics of this reactor are intermediate between those of the plug-flow and complete-mix systems. Biotransformation of PCE into innocuous compounds is desirable; however, unfortunately cDCE, which is itself toxic, was the main product of PCE dechlorination in this reactor system. In order to establish a system for complete detoxification of PCE, co-immobilization of C. bifermentans DPH-1 with other bacteria that degrade cDCE aerobically or anaerobically to ethene or ethane may be effective.

화학적 전처리를 통한 혐기성 슬러지 처리효율의 향상 (Performance Enhancement of Anaerobic Treatment of Waste Sludge by Chemical Pretreatment)

  • 허준무;박종안;손부순
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.16-25
    • /
    • 1998
  • Laboratory-scale experiment using anaerobic fluidized bed reactor was carried out to investigate the prehydrolysis step with caustic soda on the treatment efficiency of anaerobic sludge treatment, since the overall rate-limiting step for the complete anaerobic digestion of sludge was the hydrolysis step by extracellular bacterial enzymes of insoluble polymeric molecules. Reactors received a sludge which had not been pretreated, a 50-50 mixture of pretreated and untreated sludge, and the fully pretreated sludge. Hydraulic retention time of 10, 5, 2.5 days and 1 day were applied with an respective equivalent organic loading rate of 1.17, 2.23, 4.17, 11.24 gCOD/L/d. Reactor with the untreated sludge did not archieve adequate digestion even at the HRT of 5 days, and reactor, which received the 50-50 mixture, operated well at the HRT of 5 days, but began to show signs of unstable digestion at the HRT of 2.5 days. While, reactor, which was fed the hydrolyzed sludge, operated reasonably well at the 2.5 days, but was showing somewhat decrease in removal efficiencies. Results, therefore, have substantiated that the limiting reaction in the anaerobic treatment process is hydrolysis. The soluble COD did not significantly accumulate in the reactor as organic acid form, even when they were highly stressed. It was believed that this resistance to a build-up of organic acids and soluble COD behavior was mainly due to the maintenance of the methane bacteria in the fixed-film system which prevents washout as the organic loading increased. The anaerobic fluidized bed reactor was therefore effective for the digestion of waste activated sludge at short HRT.

  • PDF

혐기성 미생물부식에 의해 생성되는 철화합물 추정식 개발 (The Development of Estimation Model for Iron Compound Originated from Anaerobic Microbial Corrosion)

  • 전석준
    • 한국물환경학회지
    • /
    • 제18권4호
    • /
    • pp.379-386
    • /
    • 2002
  • In this study, estimation model for iron compound originated from upflow, anaerobic fixed bed reactor, which treats sewage domestic wastewater, was developed. The estimation model was formulated by a mathematical expression which was based on the mass balance. Below the HRT of 60 minute, sulfide concentration combining with iron $FeS_2$ is the highest because the maximum sulfate consumption rate $V_{maxS}$ and half-saturation constant of sulfate $K_{mS}$ exert an important effect on the estimation model as temperature was increased. But increment of $FeS_2$ concentration is weakened above the HRT of 60 minutes and represent the lowest value at the HRT of 108 minutes. It implies that liquid phase distribution ratio of sulfide ${\alpha}r$ becomes lower as temperature was increased. While phosphorus concentration combining with iron $Fe_3(PO_4)_3$ is increased as HRT and temperature are increased, which is affected by phosphorus removal rate constant $k_p$. As the result of estimating the iron concentrations of corrosion by the model, the concentration of iron corrosion is higher than any other at the HRT of 108 minute and $20^{\circ}C$. The predicted values were compared with measured ones at different HRT(13.5, 27, 54, 108 min) and temperature(20, 25, $30^{\circ}C$). The experimental data could be fitted with the simulated curves. Therefore, the mathematical expression could be applicable to design full-scale wastewater treatment plants.

탈염소화 미생물 부착 혐기성 고정막 반응기에 의한 테트라클로로에틸렌(PCE)의 분해 (Degradation of Tetrachloroethylene (PCE) by a Dechlorinating Enrichment Culture Fixed in an Anaerobic Reactor)

  • 이태호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제9권3호
    • /
    • pp.49-55
    • /
    • 2004
  • 염화에틸렌 화합물에 오염된 토양으로부터 고농도 (150mg/L)의 PCE를 cis-DCE까지 탈염소화하는 혼합미생물 농화 배양계 LYF-1을 구축하였다. LYF-1은 효모추출물, 펩톤, 포름산, 아세트산, 락트산, 피루브산, 시트르산, 석신산, 글루코오스, 수크로오스, 에탄올 등을 전자공여체로 이용하여 PCE를 탈염소화할 수 있었다. 한편, PCE를 대신할 수 있는 전자 수용체에 의한 PCE 탈염소화에 미치는 영향을 살펴본 결과, NO$_3$$^{-}$와 NO$_2$$^{-}$는 PCE의 탈염소화반응을 완전히 저해하였으나, S$_2$O$_3$$^{-2}$ , SO$_3$$^{-2}$ 및 SO$_4$$^{-2}$ 는 PCE의 탈염소화반응에 그다지 큰 영향을 미치지 않았다. LYF-1 혼합미생물을 혐기성 고정생물막 반응기내의 세라믹 메디아에 부착하고, PCE의 유입부하율 변화에 따른 처리 효율을 조사한 결과, PCE의 부하율 0.13-0.78 $\mu$moles/L/hr의 범위 내에서 99% 이상의 PCE 탈염소화 효율을 보였으며, PCE 탈염소화 반응의 최종산물은 cis-DCE이었다.

축산폐수의 혐기성 고정법에 있어서 암모니아성 질소의 영향 (Effect of ammonium nitrogen in anaerobic biofilter using live-stock-wastewater)

  • 엄태규;임정원
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.43-53
    • /
    • 1997
  • In this research, the synthetic livestock wastewater was prepared to study the characteristics of organic matter removal, the change of VFA production, and the amount of gas production with respect to the change of ammonium nitrogen concentration in the waste using anaerobic fixed bed process, which is an anaerobic biofilm process. The HRT and operation temperature were 1 day and $35{\pm}1^{\circ}C$, respectively. Also, the characteristics of organic matter removal and the inhibitory effect on microorganism in the anaerobic process were studied on the organic loading and ammonium nitrogen concentration. The results obtained were as follows: For COD loading of $10kg/m^3$-day and five levels of ammonium nitrogen concentration ranging from 1,000 to 5,000 mg/L, organic removal efficiencies were about 81, 74, 67, 58, and 51%, and gas productions were 3,860, 3,520, 3,240, 3,020, and 2,790 ml/l-day, respectively. Average methane contents in the gas produced on COD loading of $10kg/m^3$-day was about 76%. Throughout the whole period of experiment, remaining VFA (as COD base) in the effluent was over 90% of remaining COD. This result indicated the inhibitory effect of high concentration of ammonium nitrogen through the facts that accumulated VFA was almost COD and organic removal efficiency decreased also with the increase of ammonium nitrogen. Especially, that implys which high concentration of ammonium nitrogen not only inhibits methane forming bacteria, but also acid forming bacteria.

  • PDF

자연정화공법에 의한 농촌 전원독립가구 하수처리장에서 하수 중 오염물질의 존재형태별 거동과 분해속도 (Behavior and Decomposition Velocity of Pollutants on Various Forms from Domestic Sewage in Small-scale Sewage Treatment Plant by Natural Purification Method)

  • 서동철;김형준;박우영;임종서;황승하;박찬훈;최정환;이홍재;이도진;조주식;허종수
    • 한국환경농학회지
    • /
    • 제27권1호
    • /
    • pp.18-26
    • /
    • 2008
  • 본 연구는 농촌전원독립가구 하수처리장에서 오염물질의 존재형태별 처리 경향을 파악하여 하수처리장의 설계 및 시공 시 부지면적 감소와 오염물질의 처리효율 극대화를 위한 기초자료로 활용하기 위하여 농촌전원독립가구 하수처리장에서 하수 중 오염물질의 거동 특성과 오염물질의 존재형태별 분해속도를 각각 조사하였다. 하수 중 오염물질의 존재형태별 거동을 조사한 결과 BOD 및 COD는 대부분 호기성조에서 처리되었으며, 처리된 BOD와 COD는 대부분 insoluble형태이었다. 그러나 무산소조와 혐기성조에서의 BOD와 COD는 존재형태별로 별 차이 없었다. SS는 대부분 호기성조에서 처리되었으며, 처리된 SS는 대부분 volatile 형태이었다. T-N은 BOD, COD 및 SS와 달리 호기성조에서 처리효율이 높지 않았고, 처리된 대부분의T-N은 dissolved 형태이었다. T-P는 모든 조에서 일정하게 처리효율이 증가되었으며, 처리된 T-P는 대부분 dissolved 형태이었다. 현장 하수처리장에서 존재형태별 오염물질의 분해속도를 조사한 결과 BOD, COD 및 SS의 분해속도는 호기성조에서 각각 30.79, 17.15 및 29.96 $day^{-1}$로 무산소조 및 혐기성조에 비해 매우 빨랐으며, 호기성조에서 존재형태별 분해속도는BOD 및 COD의 경우 insoluble 형태가 빨랐으며, SS의 경우 fixed 형태가 빨랐다. T-N 및 T-P의 분해속도는 호기성조에서 각각 4.78 및 13.09 $day^{-1}$로 다른 조에 비해 약간 빨랐으며, 호기성조에서 존재형태별 분해속도는 suspended 형태가 약간 빨랐고, 혐기성조와 무산소조에서는 별 차이 없이 비슷하였다. 이상의 결과는 하수처리장의 설계 및 시공 시 부지면적 감소와 오염물질의 처리효율 극대화를 위한 기초자료로 활용 할 수 있을 것으로 판단된다.