• Title/Summary/Keyword: Anaerobic/aerobic system

Search Result 128, Processing Time 0.03 seconds

Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System (혐기-호기 공정을 이용한 염료페수의 생물학적 처리)

  • 박영식;문정현;안갑환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

Biological Treatment of Textile Wastewater by Anaerobic-Aerobic Reactor System (Pilot 혐기-호기 공정을 이용한 염색폐수의 생물학적 처리)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.11-20
    • /
    • 2001
  • An anaerobic sludge-aerobic fixed-bed biofilm(packed with ceramic support carrier of 1 inch size) reactor system was built up to treat textile wastewater. The efficiency of reactor system was examined by determining the effects of textile wastewater ratio(from 25% to 100% at HRT 24 h). The influent range of SCOD concentration and color were 1,036~1,357 mg/L, and 1,487~1,853 degree, respectively. When textile wastewater ratio was 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% and the removal efficiency of the whole system were 75.8%. Color removal efficiency by the anaerobic stage were 45.4%(soluble color), and the removal efficiency of the whole system were 70.2%. In the A/A reactor system, the aerobic stage played an important role in removing both color and COD as well as anaerobic stage.

  • PDF

Anaerobic-aerobic granular system for high-strength wastewater treatment in lagoons

  • Hamza, Rania A.;Iorhemen, Oliver T.;Tay, Joo H.
    • Advances in environmental research
    • /
    • v.5 no.3
    • /
    • pp.169-178
    • /
    • 2016
  • This study aimed at determining the treatability of high-strength wastewater (chemical oxygen demand, COD>4000 mg/L) using combined anaerobic-aerobic granular sludge in lagoon systems. The lagoon systems were simulated in laboratory-scale aerated and non-aerated batch processes inoculated with dried granular microorganisms at a dose of 0.4 g/L. In the anaerobic batch, a removal efficiency of 25% was not attained until the 12th day. It took 14 days of aerobic operation to achieve sCOD removal efficiency of 94% at COD:N:P of 100:4:1. The best removal efficiency of sCOD (96%) was achieved in the sequential anaerobic-aerobic batch of 12 days and 2 days, respectively at COD:N:P ratio of 200:4:1. Sequential anaerobic-aerobic treatment can achieve efficient and cost effective treatment for high-strength wastewater in lagoon systems.

Comparison of Anaerobic and Aerobic Sequencing Batch Reactor System for Liquid Manure Treatment (액상가축분뇨처리에서 혐기성 및 호기성 연속 회분식 반응조 시스템의 비교 연구)

  • Hong, Ji-Hyung
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.113-118
    • /
    • 2008
  • Sequencing batch operation consists of fill, react, settle and decant phases in the same reactor. Operation consists of anaerobic, anoxic and oxic (aerobic) phases when nutrient removal from the wastewater is desired. Since the same reactor is used for biological oxidation (or mixing) and sedimentation in aerobic and anaerobic SBR operations, capital and operating costs are lower than conventional activated sludge process and conventional anaerobic digestion process, respectively. Therefore, Aerobic SBR and Anaerobic SBR operations may be more advantageous far treatment of small volume animal wastewater in rural areas.

  • PDF

The Function of Multiple Pribnow Box on the Aerobic-Anaerobic Switch Control of aeg-46.5 Gene Expression

  • Gang, In O;Jeong, Yeon Ju;Choe, Mu Hyeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.903-908
    • /
    • 2001
  • The gene aeg-46.5, which is expressed under anaerobic condition, has putative triple -10 regions and four transcription start sites. The mRNA transcription level and its start point change depending on the aerobic/anaerobic growth condition. RNA polymerase and its regulatory proteins must choose which of three -10 region to use. The putative triple 10 region was mutated to make only one of them function with consensus -10 region sequence (TATAAT) and the other two as non-functional region. The results show that the second and third -10 regions are used for the aerobic/anaerobic expression. The third -10 region is responsible for the high aerobic to anaerobic switch ratio. This suggests that only the last two of the putative triple -10 region have functions on aeg-46.5 gene expression switch control. The phenotype of the mutated promoter was tested in the wild type cell and narL - cell. The results indicate that the control by NarL is independent from the selection of -10 region. The expression patterns on multi-copy plasmids and on single-copy chromosome were compared. These results show that the aerobic/anaerobic switch control of aeg-46.5 is through the choice of -10 region. The mechanism of choosing different -10 region remains to be seen.

Tuning the Parameters for the Decision Making System in Order to Define Athlete's Aerobic and Anaerobic Thresholds

  • Ketola, Jaakko;Saastamoinen, Kalle;Turunen, Esko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.317-320
    • /
    • 2004
  • In this work we have managed to find parameters for defining athlete's aerobic and anaerobic thresholds. Thresholds which are of vital importance for top athletes. It is shown how differential evolution and different similarity measures has been used to tune computational model for threshold definitions. From our results it is obvious that the use of right parameter values for this kind expert system is of vital importance.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • 이민규;서근학
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • Lee, Min-Gyu;Suh, Kuen-Hack
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

Comparison of Biological Phosphorus Removal Characteristics between A/O and A2/O Process (A/O 및 A2/O공정의 생물학적 인제거 특성비교)

  • Kim, Kwang-Soo;Seo, Gyu-Tae;Lee, Kyung-Ho;Kim, Nag-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.123-130
    • /
    • 2002
  • Bench scale experiments were carried out with two biological nutrient removal(BNR) units, A/O and $A^2O$ processes, to investigate the behavior of phosphorus in the system and to compare the characteristics of phosphorus removal in two BNR processes. To achieve this goal, COD/T-P and COD/TKN ratios of the influent was varied in the range of 23~64 and 5~24, respectively. In A/O process, influent COD/T-P ratio should be kept higher than 44mg/L to meet the final effluent T-P concentration lower than 1mg/L and in $A^2/O$ process, influent COD/T-P and COD/TKN ratios higher than 56 and 10, respectively, were required for good phosphorus release and uptake with no influence of nitrate nitrogen in return sludge. At this conditions, the rate of phosphorus release in the anaerobic basin should be kept higher than 0.1 kg S-P/kg MLVSS d In A/O process, the phosphorus content of anaerobic and aerobic sludges was increased as SRT of total system was becoming longer resulting in decreasing the difference of phosphorus content between two sludges while phosphorus release in anaerobic basin and phosphorus uptake in aerobic basin was not incident. In $A^2/O$ process, the phosphorus content of anaerobic and aerobic sludges were not increased with higher SRT of total system due to the relatively high nitrate concentration in return sludge. However, the difference of phosphorus content between anaerobic and aerobic sludges was incident when phosphorus release and uptake was observed.

Color Removal of Real Textile Wastewater by Sequential Anaerobic and Aerobic Reactors

  • Oh You-Kwan;Kim Yu-Jin;Ahn Yeonghee;Song Seung-Koo;Park Sunghoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.419-422
    • /
    • 2004
  • Textile wastewater from the Pusan Dyeing Industrial Complex (PDIC) was treated utilizing a two-stage continuous system, composed of an upflow anaerobic sludge blanket reactor and an activated Sludge reactor. The effects of color and organic leading rates were studied by varying the hydraulic retention time and influent glucose concentration. The maximum color load to Satisfy the legal discharge limit of color intensity in Korea (400 ADMI, unit of the American Dye Manufacturers Institute) was estimated to be 2,700 $ADMI{\cdot}L^{-1}\;day^{-1}$. This study Indicates that the two-stage anaerobic/aerobic reaction system is potentially useful in the treatment of textile wastewater.