• 제목/요약/키워드: An apartment house

검색결과 392건 처리시간 0.024초

단독가구노인의 주거만족도에 관한 연구 - 도시.농촌지역간의 비교를 중심으로 - (A Study on the Housing Satisfaction of Elderly Living Alone or with Spouse - A Comparision between Urban and Rural Area -)

  • 이경희;장온정
    • 가정과삶의질연구
    • /
    • 제9권2호
    • /
    • pp.225-240
    • /
    • 1991
  • The purpose of this study is to find the main factor which influences the housing satisfaction of elderly who lives alone or with spouse and to make it sure that housing satisfaction is an important factor to life satisfaction of elderly. The specific purpose of this study is as follows; 1) How does the locus of control of elderly influence a housing satisfaction\ulcorner 2) How does the housing characteristics of elderly influence on the housing satisfaction and this relationship has any difference between urban and rural area. 3) Which variables influence upon the housing satisfaction and life satisfaction of elderly and how much do they influence \ulcorner The locus of control scale, housing satisfaction scale. life satisfaction scale were composed on the basis of precedent researches. For this study 202 elderly sho live in urban and rural area ere interviewed. To analyze the data, such as F-test, t-test, two-way ANOVA, Multiple regression analysis were used with SPSS program. The results are as follows; 1) The interrelation between locus of control and housing satisfaction is as follows. Namely , if he believes in his deeds and will rater than his fate, he feels more housing satisfaction. 2)the housing satisfaction of the elderly was found to be influenced by location, Namely, the elderly living in the urban area feels more housing satisfaction, especially he lives in apartment and unshared house. On the contrary, the elderly living in the rural area was not affected by housing type and the number of household who live together, The housing satisfaction of the elderly living in the rural area or the urban area equally influenced by the housing tenure, heating system, bathroom facility, flush toilet, and convenient service form the outside. 3) The main factoers which influence the housing satisfaction of the single household elderly are bathroom facility louse of control and income. When we concern about the location in urban area the housing satisfaction of the elderly were mainly influenced by income, but in the rural area, they were influenced by the service facility from the outside. As a Conclusion, the main factor which influenced life satisfaction of the elderly proved to be housing satisfaction inn both rural and urban area.

  • PDF

영상전화기(비디오폰) 판매 활성화방안 연구 - 서울시를 중심으로 - (A Study on Sale revitalization Video Phone Market - The Case of Seoul City -)

  • 김대윤;이상윤
    • 유통과학연구
    • /
    • 제7권1호
    • /
    • pp.35-53
    • /
    • 2009
  • 본고는 홈네트워크 시장에 대한 관심이 증대되고 있는 가운데 이미 건축된 주택(기축시장)을 대상으로 영상전화기(비디오폰)의 판매활성화 방안을 찾는데 목적을 두고 있다. 최근 가전, 네트워크장비, 통신서비스업체들은 새로운 시장을 보며 홈 네트워크에 관심을 가지고 있는데 대부분의 홈네트워크 시장은 신축 고급아파트를 중심으로 활성화되고 있다. 신축시장의 경우 최종고객의 선택권이 없기 때문에 건설 회사를 통해 영업.마케팅을 해야 한다. 그래서 신축시장은 개별적인 수요파악이 어려워 판매활성화를 통해 수익을 창출하는데 에는 한계가 있다고 판단하여 기축시장을 대상으로 향후 수요가 서민주택으로까지 확대될 것에 대비해 기능이 단순하고 가격이 저렴한 보급형 비디오폰 시장개척에 더 많은 노력이 요구된다고 할 수 있다. 이러한 이유로 본고에서는 비디오폰의 개념과 시장동향을 분석하고, 유통경로형태와 A/S 처리시스템을 파악하며 기축시장에 적합한 비디오폰 판매활성화 방안을 모색하는데 그 목적이 있다.

  • PDF

필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 - (A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes -)

  • 최승복;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.48-54
    • /
    • 2016
  • 대부분 필로티 구조 건물은 필로티를 통해야만 출입이 가능한 구조이고 주차장으로 사용할 경우 차량이 연쇄적으로 소훼되면서 짧은 시간에 필로티 전체로 확산된다. 연소 하중이 높은 차량과 천장 단열재에서 생성된 뜨거운 열기와 유독가스는 출입문을 파손시키고 건물내부로 유입되어 계단과 승강기 그리고 전선이 지나가는 피트(EPS)와 같은 경로를 통해 건물 상층으로 확대된다. 필로티에서 화재가 발생할 위험성은 다양하다. 만약 이곳에서 화재가 발생할 경우 입주민들은 건물에 갇혀 생존에 위협을 받을 수밖에 없다. 본 연구는 필로티에서 화재가 발생하여 5명이 사망하고 139명의 다친 의정부 아파트 화재 사례를 살펴보고 필로티 구조의 건물의 화재 취약성을 분석하였다.

저성장속도 화재에서의 스프링클러 헤드 동작특성에 관한 실험적 연구 (An Experimental Study on Characteristics of Sprinkler Head Activation in Low Growth Rate Fire)

  • 최용섭;윤종칠
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.26-35
    • /
    • 2016
  • 스프링클러 설비는 화재 발생 시 화재를 초기에 제어 및 진압하는 설비로서 어떠한 화재 분위기에서도 스프링클러 헤드의 작동온도에서 정상적인 동작을 하여야 한다. 그러나 최근 화재성장속도가 느린 화재 발생 장소에서 일부 조기반응형 스프링클러 헤드가 정상적인 동작을 하지 않을 수 있다는 문제가 제기되고 있다. 이에 본 논문에서는 공동주택 침실규모의 모형실험 및 캐비넷형 버너를 이용하여 화재성장속도가 느린 조건을 형성하고 실제 현장에서 배관 내에 가해지는 최소압력인 0.2MPa 이상의 가압수를 공급하여 실험을 진행하였다. 실험결과 국내에서 사용되고 있는 과반수 이상의 플러쉬형 조기반응형 스프링클러 헤드에서 Cold Soldering 현상이 발생되면서 불완전하게 개방되는 것이 확인되었다. 이러한 현상은 화재 조기진압 및 제어에 실패하여 화재확산 및 인명피해의 원인이 될 수 있으므로 추가적인 연구를 통해 국내 형식승인 및 제품검사기준의 보완의 필요할 것으로 판단된다.

단지설계업무에서 3차원 공간자료의 활용 (A Pilot Site Planning and Design based on 3D Spatial Information)

  • 황철수;이상훈
    • 토지주택연구
    • /
    • 제3권1호
    • /
    • pp.15-22
    • /
    • 2012
  • 본 연구는 단지설계과정에서 3차원 공간정보 가운데 최근 각광을 받는 LiDAR 자료를 통합하여 정보의 정확성을 높이고 활용성을 확인하는데 목표를 둔 연구이다. 즉, 실제 활용되는 프로그램인 LH공사 업무 중 단지설계프로그램인 DAS를 연구의 대상으로 삼아 3차원 공간정보의 적용가능성을 알아보고 이를 효과적으로 적용시키기 위한 시뮬레이터를 개발하여 구현하였다. 이를 위해 사례연구지역을 선정하여 개발 전 후의 모습을 시뮬레이션하고 이 과정에서 개발 전 모습을 LiDAR 자료를 이용한 방법과 기존의 수치지도 이용 방법에 따른 정확성을 살펴보고, 개발 후 모습을 설계자료를 이용하여 구현하였다. 그 결과 횡단면분석을 통해 분석한 결과 LiDAR가 기존의 지리정보 데이터 보다 높은 정확성을 지니고 있음을 알 수 있었다. 또한 LiDAR 데이터를 활용하여 생성된 수치표고모델(DEM)을 등고선으로 추출하여 DAS프로그램에 적용하는 방안을 제시하였으며, 설계자료를 이용한 모델 생성 일반화식을 제시하였다. 3차원 공간정보를 활용한 시뮬레이터 개발은 3차원 지형모델을 이용한 3차원 공간분석, 3차원 공간정보를 바탕으로 한 의사결정 업무에 활용 가능할 것으로 예상된다.

차광판 표면 처리 방법에 따른 전사광 변화에 관한 연구 (Study on a Forward Light Changes According to the Surface Treatment of Light Cutoff Panel)

  • 구진회;권명희;이윤경
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.1-5
    • /
    • 2014
  • Since the "Light Pollution Prevention Act" was executed, the installation of the light cutoff panel to the security lightings which caused light trespass has been increased in the local government. The light cutoff panel is effective in reducing the light trespass in term of the cost-benefit. Because the installation of the light cutoff panel is inexpensive than the change of the security lighting. But the reflected light from the surface of the light cutoff panel has been regarded as another light pollution problem to solve. Therefore, we try to improve light cutoff panel by changing the light reflectivity characteristic of the surface of the light cutoff panel. First, we laminated the surface of light cutoff panel by black powder to reduce the light reflectivity of the light cutoff panel. After the black powder lamination, the light reflectivity on the light cutoff panel improved from 85% to 5%. And we compared reflected light caused by black powder laminated light cutoff panel with the one of no surface treatment cutoff panel. The vertical illuminance was measured at 3, 6, 9m in front of the security lighting and 3, 6, 9, 12, 15, 18m in back of the security lighting to evaluate the reflected light. And the measurement height was determined of 1.5m considering the height of the 1th floor of an apartment house. In this study, we found that the reflected light from the light cutoff panel can be reduced about 90% by the black powder lamination method. The results derived from this study will be helpful to develope the various kind of light cutoff panel which minimize the adverse effect like reflected light of light cutoff panel.

Stock composition and Renovation Possibility of urban Style Row-rise Houses for rent

  • Park, Byung-Soon;Matsumura, Shuichi
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.307-313
    • /
    • 2002
  • Urban style row-rise houses for rent have been supplied to the center of city from the 1950's first half The amount of stock is about 450,000 houses and occupies about 40% in the private rented house. As for the structure, the 60% of them is wooden-structure and the rest is non-wooden. Stocks of 57.5% of the wooden-structure and 86% of the non-wooden were built after 1981 years. It was 1981 years that the new earthquake-resistant standard was carried out, the improvement of stocks built before 1981 is necessary because those don't satisfy the present standard. To investigate the renovation possibility of urban style row-rise houses for rent, actual situation of two-story apartment at 2,4, and 5 Chome Taito-Ku in Tokyo was surveyed from July to November 2001. The number of building analyzed is 227 ridges among 234 ridges of the surveyed two-story building. 90% of building analyzed is wooden structure. 1) The site of 88% building surveyed is close to a road less than 4m width. It becomes the existing non-conformed building in the building construction act. It is impossible to make a renovation such as rebuilding, extension and remodeling because it requires the set back when renovating this type of non-conformed building, 2) The building built before 1981 is almost wooden-structure, and occupies 37% of the building surveyed, and doesn't satisfy the present earthquake-resistant standard. An improvement of them is needed because the decrepitude of building proceeds. 3) 50% of openings and 40% of windows of the building surveyed doesn't use noncombustible materials. Though it becomes the existing non-conformed building, it can satisfy the present standard by replacing openings with noncombustible materials.

  • PDF

필러겸용 스포터로 지지되는 전구간 알루미늄 슬래브 거푸집의 저소음 안전낙하 공법개발 및 적용연구 (Development and Implementation of a Low-noise and Safe Dismantling Method for Full-Span Aluminum Slab Formwork Supported by Filler Supports)

  • 임남기
    • 한국건축시공학회지
    • /
    • 제24권2호
    • /
    • pp.261-271
    • /
    • 2024
  • 국내외 건설현장에서 사용빈도가 급격히 증가하고 있는 슬래브용 알루미늄 폼은 탈형시 바닥으로 그대로 떨어뜨리는 경우가 많아 소음으로 인한 주변 민원이 발생하고, 높은 위치에서 떨어지면서 형틀이 변형되거나 바닥에서 튀어 오로면서 주변 인부들에게 상해를 입히기도 하여 중대재해처벌법이 강화되는 현실에서 개선이 절실한 상황이다. 이에 본 연구에서는 공동주택의 1세대 슬래브 거푸집 전체가 동시에 작업자가 펼친 손이 닿는 위치까지 안전하게 낙하되면 자유롭게 분해하여 다음 층으로 인양할 수 있게 함으로써 안전성, 품질, 경제성, 공정이 개선된 필러서포터 존치형 공법으로써 슬래브의 처짐문제 해결 등의 장점을 확인되고 건설신기술을 획득하였으므로 적극적인 시장개척을 통한 적용 활성화가 가능할 것으로 판단된다.

국민연금기금의 대체투자를 통한 청년층 공공임대주택 공급 후보지 분석: 2011-2016년 수도권 아파트 거래 자료를 토대로 (A Study on Public Rental Housing for Young Generation Utilizing an Alternative Investment of National Pension Fund: Using Apartment Trading Data on Seoul Metropolitan Area from 2011 to 2016)

  • 조성아;홍예륜;이성민;신휴석
    • 한국경제지리학회지
    • /
    • 제21권2호
    • /
    • pp.156-172
    • /
    • 2018
  • 한국의 지속적인 인구 고령화는 다양한 사회 갈등을 야기하고 있는데, 국민연금기금 고갈에 대한 위기감은 청년층과 기성세대 간의 첨예한 갈등의 한 양상이 되고 있다. 특히 청년층의 주거복지 수요가 증가하는 가운데, 국민연금기금의 대체투자를 통한 공공임대주택 공급 방안에 대한 사회적 관심이 증가하고 있다. 본 연구는 국민연금기금을 통한 청년층 공공임대주택 공급의 당위성을 검증한다. 그 후 공간통계기법에 기반한 탐색 결과를 바탕으로, 공공임대주택의 수도권 내 후보지를 제안하는 것을 목표로 한다. 연구 결과 세 가지 세부 청년층 분류에 따른 공공주택 공급방안이 도출되었으며, 각 지역과 대상 계층에 적합한 공공임대주택을 공급하는 방안을 모색한다. 본 연구를 통해 한국 사회의 세대 갈등을 완화하고, 국민연금기금의 수익성과 공공성을 모두 충족함을 목표로 한다.

초고층 공동주택의 주방.욕실 배기 풍속을 풍력발전에 활용하는 방안 (A Study on the Wind Power Generation Using Vertical Exhaust Air Duct of the High-Rise Apartments)

  • 이용호;김성용;황정하;박진철
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.1-10
    • /
    • 2012
  • The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows: 1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of $0.16m^2{\sim}0.4m^2$. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct/area of PS section ${\times}$ 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01~3.98m/s and contribute to the proper wind velocity level (3.0m/s). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The "entire house holds" condition for exhaust fan operation provided more even exhaust wind velocity than the "some house holds" condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.