• Title/Summary/Keyword: An Open Type

Search Result 1,226, Processing Time 0.032 seconds

Performance Tests of Oil Boom at Open Sea (오일붐의 실해역 성능평가 기법 개발)

  • Yu Jeongseok;Lee Moonjin;Kim Jinhwan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.49-62
    • /
    • 1999
  • The main functions of oil booms are to prevent spreading of the oil slick and to increase the recovering efficiency of oil skimmers. The oil-containment capability of a floating boom on an open sea is affected by environmental parameters such as waves, currents and winds, as well as the motion characteristics of a boom section. In this study, a series of tests were conducted for three kinds of booms (internal foam type, air inflatable type, self-expanded type) at the open sea off Yosu, and the results are presented. Motion characteristics and oversplashing phenomenon were observed for each boom in different environmental conditions. And the tension exerted on towing line of the boom was also measured with a systematic varitation of towing speeds and gap ratios.

  • PDF

A Study on the Analysis of the View Target in an Apartment Unit (아파트 각 단위세대에서 보이는 조망 경관 대상 분석에 관한 연구)

  • Kwon, Young-Taek;Moon, Ji-Won;Ha, Jae-Myung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.221-226
    • /
    • 2004
  • View targets have been studied extensively in terms of an aesthetic value and a monetary asset. But there was actually deficient in the research about a variety of view targets. Therefore, the purpose of this paper was to classify systematically into diverse view targets in an apartment unit by the use of both the literature methods and the questionnaire-interview survey. In result, the view targets in an apartment unit were categorized by two large groups which are a natural-type and an artificial-type view. The former was subdivided into a pure natural-type and a man-made natural-type view, while the latter was subdivided into a building-type, a street-furniture-type, a road-type, a open-space-type, and a tower-type view. Consequently, this study might be applied to the understanding of the quality of residential environment as a basis.

  • PDF

Outcomes of Immediate Operative Treatment of Ankle Trimalleolar Open Fractures (족관절 개방성 삼과골절의 즉각적인 수술의 결과)

  • Lee, Jun-Young;Cho, Yong-Jin;Kang, Sin-Wook;Cho, Yung-Min;Choi, Hyun-Bai
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.1
    • /
    • pp.25-30
    • /
    • 2020
  • Purpose: Generally, the treatment of ankle trimalleolar open fractures is divided into two stages: external fixation and debridement; and secondary internal fixation. On the other hand, this two-stage operation takes considerable treatment time and is challenging in procedures requiring reduction. The purpose of this study was to evaluate the radiologic and clinical results of an immediate one-stage internal fixation operation considering the wound conditions to overcome two stage operation disadvantages. Materials and Methods: From September 2009 to January 2018, 24 cases of ankle trimalleolar open fractures, who underwent immediate internal fixation and were followed up for at least one year, were studied retrospectively. The open wound was divided into the Gustilo-Anderson classification. Open reduction and internal fixation were performed on every medial and lateral malleolar fracture. On the other hand, with posterior malleolar fractures, surgical or conservative treatment was performed depending on the fragment size. The radiologic outcome was evaluated using the Burwell and Charnley criteria and American Orthopaedic Foot and Ankle Society (AOFAS) scores, and complications, such as infection and posttraumatic arthritis, were used for the clinical evaluation. Results: The wound was classified into eight cases (33.3%) of type I, 11 cases (45.8%) of type II, and five cases (20.8%) of type IIIa. The degree of reduction was anatomical, fair, and poor in 16 cases (66.7%), six cases (25.0%), and two cases (8.3%), respectively. The mean AOFAS score was 79 points, and there were complications, such as infection in three cases (12.5%) and post-traumatic arthritis in two cases (8.3%). Conclusion: Satisfactory results were obtained through immediate surgical treatment in ankle trimalleolar open fractures of types I, II, and IIIa.

A Study on Effective Energy Use of the Open Type Ground Heat Exchanger Using Underground Temperature Gradient (지중온도 경사를 이용한 효율적 지중에너지 이용 방안에 관한 연구)

  • Ryu, Hyungkyou;Chung, Minho;Lee, Byungseok;Rhew, Hyojun;Choi, Hyunjun;Choi, Hangseok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.401-408
    • /
    • 2014
  • This paper proposes an optimum operation method for open type ground heat exchangers. A series of TRTs and artificial heating/cooling operations were carried out while monitoring temperature in the hole of SCW. The ground temperature naturally increases with depth, but a switch between the cooling/heating mode results in a change in the distribution of ground temperature. The effect of the mode change was evaluated by performing LMTD and COMSOL multiphysics analysis for a reduced model with the depth of 150 m. As a result, in the cooling mode, the upstream operation is more efficient than the downstream operation and reduces EWT by $2.26^{\circ}C$. On the other hand, in the heating mode, the downstream operation is advantageous over the upstream operation and increases EWT by $3.19^{\circ}C$. The merit of the optimum operation will be enhanced for the typical dimension of SCW with a depth of 400~500 m. In the future, an open type ground heat exchanger system adopting the optimum operation with variation in the ground temperature will be used in practice.

An Optimal Threshold Control in an Open Network of Queues (개방대기 네트웍에서의 최적 Threshold 제어)

  • Kim, Sung-Chul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.17 no.2
    • /
    • pp.107-113
    • /
    • 1991
  • This article develops a control model for an open queueing network in terms of both the input and the output processes with stochastic intensities. The input and the output intensities are subject to some capacity limits and optimum control is characterized by a threshold type with a finite upper barrier. A discounted profit is used as a decision criteria, which is revenue minus operating and holding cost.

  • PDF

Stellar Content of the Massive Young Open Cluster Westerlund 2

  • Hur, Hyeonoh;Park, Byeong-Gon;Sung, Hwankyung;Lim, Beomdu;Chun, Moo-Young;Bessell, Michael S.;Sohn, Sangmo Tony
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.84.1-84.1
    • /
    • 2014
  • We report the spatial distribution of early-type stars and pre-main-sequence (PMS) stars around the starburst type young open cluster Westerlund 2. The early-type were selected from UBVI photometric data, while the PMS members were identified from their X-ray emission and mid-infrared excess. The northern clump of the cluster is composed mainly of PMS stars detected in both optical and X-ray and seems to be coeval to the cluster, while PMS stars in the bright bridge region are highly obscured in optical wavelength. The bright bridge appear to be an on-going star forming region possibly triggered by the strong radiation field from both sides-massive stars in Westerlund 2 and WR 20b. We also found that there are many early-type stars not only in the cluster but also farther from the cluster up to several times of the cluster radius. These early-type stars are well aligned from east to southwest of the cluster. We conclude these early-type stars are members of an OB association in the RCW 49 nebula. This report indicates there is a complex star formation history in Westerlund 2 and its surrounding H II region, the RCW 49 nebula.

  • PDF

A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications (저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구)

  • 안태영;황선민;조인호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.4
    • /
    • pp.183-190
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58${\times}$61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications (저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구)

  • 안태영;황선민;조인호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.183-183
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58×61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

Development of an UV Distribution Model for the Design of a Submerged UV Disinfection Reactor and Its Application (침지형 자외선 살균조 설계를 위한 자외선 분포 모델의 개발 및 적용)

  • Park, Changyeun;Kim, Sunghong;Choi, Younggyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.505-512
    • /
    • 2021
  • A 3D model was developed to calculate the UV intensity of a submerged-type UV disinfection reactor. Numerical experiments were conducted by inputting the design factors of an open channel-type disinfection reactor and a pipe-type disinfection reactor that were installed in an actual sewage treatment plant. The following data were obtained: The average UV intensity of the installed open channel-type reactor and pipe-type reactor was 7.87 mW/cm2 and 13.09 mW/cm2, respectively; the UV dose reflecting the UV irradiation time and taking into account attenuation effects such as mixing imbalance, lamp aging, temperature, and fouling, was expected to be 21.1 mJ/cm2 and 24.8 mJ/cm2, respectively, and these values are 5 % and 24 % higher than the target UV dose of 20 mJ/cm2, respectively. By using the UV3D model, the optimal lamp position, which maximizes the average UV intensity without changing the size of the disinfection reactor or lamp output power, can be found. In this case, by only adjusting the lamp position, the average UV intensity can be increased by 0.9 % for the open channel-type and 0.5 % for the pipe-type, respectively. A better average UV intensity can be obtained by model simulation. By adjusting the horizontal and vertical ratio of the open channel-type reactor and by moving the lamp position, the average UV intensity can be increased by 7.4 % more than the present case.

Quench Characteristics of Flux-lock type Superconducting Fault Current Limiter using Open-loop Iron Core (개루프 철심을 이용한 자속구속형 초전도한류기의 퀜치특성)

  • Nam, Gueng-Hyun;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Lee, Na-Young;Lim, Sung-Hun;Park, Chung-Ryul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.159-160
    • /
    • 2005
  • The superconducting fault current limiter(SFCLs) provides the effect such as enhancement in the power system reliability due to limiting fault current in a few miliseconds. The Flux-lock type SFCL using the YBCO film among various type SFCLs consists of the primary and the secondary copper coils that are wound in parallel each other through the iron core. The operation can be controlled by adjusting the inductances and the winging directions of each the coil. We compared the current limiting performance on the additive and the subtractive polarity winding directions in case of an open-loop iron core. To analyze quench characteristics, we experimented various phase angle.

  • PDF