• Title/Summary/Keyword: An Open Type

Search Result 1,220, Processing Time 0.027 seconds

Correction of post-traumatic anterior open bite by injection of botulinum toxin type A into the anterior belly of the digastric muscle: case report

  • Seok, Hyun;Park, Yong-Tae;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.188-192
    • /
    • 2013
  • Post-traumatic anterior open bite can occur as a result of broken balance among the masticatory muscles. The superior hyoid muscle group retracts the mandible downward and contributes to the anterior open bite. Denervation of the digastric muscle by injection of botulinum toxin type A (BTX-A) can reduce the power of the digastric muscle and help to resolve the post-traumatic anterior open bite. A patient with a bilateral angle fracture had an anterior open bite even after undergoing three operations under general anesthesia and rubber traction. Although the open bite showed some improvement by the repeated operation, the occlusion was still unstable six weeks after the initial treatment. To eliminate the residual anterior open bite, BTX-A was injected into the anterior belly of the digastric muscle. Following injection of BTX-A, the anterior open bite showed immediate improvement. Complication and relapse were not observed during follow-up. Long-standing post-traumatic open bite could be successfully corrected by injection of BTX-A into the anterior belly of the digastric muscle without complication.

A Type of Subsection Model for a Permanent Magnet Bar and its Leakage Permeance Calculation Method in an Open Magnetic Circuit

  • Liang, Huimin;You, Jiaxin;Yang, Wenying;Zhai, Guofu
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • The equivalent model of a permanent magnet (PM) plays an important role in electromagnetic system calculation. A type of subsection model for a PM bar is established, to improve the accuracy of the traditional equivalent circuit method. The mathematical expression, and its end verification condition, are presented. Based on the analytical method and finite element method, the leakage permeance calculation of a PM bar in an open magnetic circuit is investigated. As an example, for a given certain type of PM bar, the magnetic flux of each section is validated by experiment, and by simulation. This model offers a foundation for building a high accuracy equivalent magnetic PM model in an electromagnetic system.

A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD (Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정)

  • ANANIEV, Igor P.;Joe, Ki-Yeon;Byun, Young-Bok;Seo, Jeong-Il;Kim, Eun-Soo;Kim, Tae-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

Hull-Form Development of a Twin-Skeg Large Ro-Pax Ferry (트윈스케그 적용 대형 로팩스선의 선형개발)

  • Lee, Hwa Joon;Jang, Hag-Soo;Hong, Chun-Beom;Ahn, Sung-Mok;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.491-497
    • /
    • 2012
  • A hull-form for a 32,000G/T class Ro-Pax ferry has developed in accordance with a need of ferry operators to reduce fuel oil consumption(FOC) due to the drastic increase in oil prices recently and strengthening of environmental rules and regulations such as CO2 emission. A twin-skeg type is applied as the hull-form in lieu of an open-shaft type in order to improve propulsion performance. In order to achieve this object, flow control devices are installed to reduce a propeller induced vibration which is a main reason to obstruct the application of twin-skeg type passenger vessels owing to an uncomfortable vibration level. Numerical simulation by using an in-house code and a commercial code (Fluent) has performed to find out an optimum design of the flow control devices and to check an improvement in cavity volume. Model tests in Samsung Ship Model Basin are carried out to evaluate propulsion performance with the developed twin-skeg type hull and a reference hull of open-shaft type. In conclusion, it is shown that the twin-skeg type hull is better than the open-shaft in FOC by around 7% and in cavity volume by 20% as well.

Changes in Benthic Macroinvertebrate Community Before and After Rainy Season in Mountain Valley with Erosion Control Dam (사방댐이 설치된 산지계곡의 장마 전·후 저서성 대형무척추동물 군집변화)

  • An, Chae-Hui;Han, Jung-Soo;Choi, Jun-Kil;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.2
    • /
    • pp.121-129
    • /
    • 2020
  • This study investigated the change of benthic macroinvertebrates community due to erosion control dams installed in Wonju, Gangwon by comparing the data before and after a rainy season. It selected a closed-type erosion control dam (boulder stone), an open-type erosion control dam (buttress), and a control area and surveyed two upstream points and two downstream points four times between March and September 2019. The flow velocity mostly increased in the closed-type, open-type, and control areas but decreased in St. 3 after the rainy season. The number of benthic macroinvertebrates species and their populations mostly decreased after the rainy season, and the rate of decrease in the populations in the open-type and control areas were more similar than the closed-type area. Species and populations of the EPT groups mostly decreased after the rainy season. A result of the similarity analysis showed that the closed-type and open-type areas were separated by 38.4% with the control area before the rainy season, but the open-type and control areas were separated by 51.3% with the closed-type area after the rainy season. A result of the principal components analysis (PCA) based on axis 1 showed that the closed-type area had a positive value before and after the rainy season, and the open-type and control areas had a negative value before and after the rainy season. The open-type area was more correlated with the control area than the close type. The analysis of the EPT groups showed the distribution of Ephemeroptera in the closed-type area and Trichoptera in the open-type and control areas. The result of this study shows that the installation of erosion control dam can cause changes in benthic macroinvertebrates community and that the open-type area had a smaller difference community difference from the control area after the rainy season than the closed-type area.

Three-Dimensional Flow Characteristics in the Downstream Region of a Butterfly-Type Valve Used in Air-Conditioning Systems (공기조화용 버터플라이 밸브 하류에서의 3차원 유동특성)

  • Park, Sang-Won;Lee, Sang-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.260-269
    • /
    • 2000
  • Oil-film flow visualizations and three-dimensional flow measurements have been conducted in the downstream region of a butterfly-type valve used in air-conditioning systems, with the variation of a disk open angle. The flow visualizations in the flow symmetry plane show that there are a pair of counter-rotating separation/recirculation zones as wall as two jet-like near-wall flows. These flow disturbances are strongly depends on the disk open angle. Based on the flow visualization, a qualitative flow model is suggested in the near-field and downstream region of the valve disk. For a small disk open angle, the mean velocities and turbulent intensities have relatively small values in the near-field of the valve disk, but they do not show uniform distributions even in some downstream region. With an increment of the disk open angle, mean velocity variations and turbulent intensities are greatly increased in the immediate downstream region, but uniform distributions are quickly resumed as departing from the valve disk. The mass flow rate remains nearly constant for the disk open angles less than 30 degrees, meanwhile it strongly depends on the disk open angles between 45 and 75 degrees. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 75 degrees.

A Study on Plan Structure Types and Characteristics of Wall Formation in Art Museum Exhibition Spaces

  • Lee, Jong-Sook
    • Architectural research
    • /
    • v.13 no.3
    • /
    • pp.3-10
    • /
    • 2011
  • The Characteristics of space are determined by several factors; however, the element that determines the physical characteristic of floors, walls, and ceiling is the structure. This study constructs a wall to analyze the direct effect that the layout of an exhibition wall has on the element of the wall followed by the structural process and visibility of descriptive analysis and examples of art museums that the shift from a perceptional wall to an experiential wall affected circulation. For elements and formation methods of the wall, first, it is made up of open and closed type exhibition spaces, and it can give abundance in qualitative space rather than a quantitative aspect. Secondly, the directivity of space changes according to the development of the visible axis, thus, directly affects the change in visibility. Thirdly, the difference between spatial structure and visual structure is the difference between the visual axis and spatial structure. The wall formation type followed by the combination method, the simple visible structure, which is the type that possesses the simple combination (Room, Zone, Cluster), repeatedly uses the same size of units of space that is orderly and has few spatial axes and the classification of simple type and simple cluster type, which has few visible axes, also exists. Also, with the complex structure of the maze type it displays the reiterated form of the cluster, which is the space with disorderly combination and has much visible axes and spatial axes. Also, these can be divided into three types: 1) Maze Cluster Type, 2) Cross Road Type, and 3) Open Flexible Type. These wall types lead the various changes in circulation, and even each of the arrangement qualities of the exhibitions should be researched according to its exhibition place type.

A Study On The Relationship Characteristics Between Inborn(Myers-Brigg's Type Indicator: MBTI) and Acquired(Personality Adaptation Type: PAT) Factors of Personality (성격의 선천적 요인(MBTI)과 후천적 요인(PAT)의 관계특성 연구)

  • Oh, Soo-Hee
    • 한국사회복지학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.757-779
    • /
    • 2004
  • The purpose of study is to provide efficient initial approaches for counseling in social work practice settings. First, it attempts to identify the correlation between the Myers-Brigg's Type Indicator(MBTI), a personality index based on the theory of psychological typology, and Personality Adaptation Types(PAT) models. Second, it attempts to develop a counseling method which can be applied to the initial interview, using the paradigm of door to therapy such as "Open Door", "Target Door", and "Trap Door" based on the PAT theory. The result of the quantitative study showed the correlation between MBTI and PAT as follows: MBTI Extrovert and Feeling(E, F) type was statistically correlated to hysterical PAT. MBTI Extrovert, Intuition and Perceiving(E, N, P) type was statistically correlated to Obsessive-Compulsive PAT. In conclusion, this study finds that when a clinical social worker approaches a client with the client's MBTI personality type and an interventional personality adaptation theory approach such as "Open Door", "Target Door", or "Trap Door", the efficiency of communication is increased significantly.

  • PDF

Operation Characteristics of Open Type Geothermal Heat Pump (개방형 지열 히트펌프 시스템의 운전 특성)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Song, Yoon-Seok;Park, Seong-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

A CASE REPORT OF OPEN TYPE HOLLOW OBTURATOR (개방형 Hollow 폐색장치의 임상 증례)

  • Chung, Moon-Kyu;Bae, Jeoung-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.207-212
    • /
    • 1988
  • Maxillary defects are a result of necessary cancer surgery, congenital anomaly or trauma. Ideally the patient with the aquired maxillary defect should be provided with an obturator prosthesis that is comfortable, restores adequate speech, deglutition, and mastication, and is acceptable cosmetically. This is a case report of open type hollow obturator delivered in the partial maxillectomy treated patient. The satisfied result obtained as follows: The open type hollow obturator has the advantage of easy fabrication, lightness, easy cleaning and restores adquate speech.

  • PDF