• Title/Summary/Keyword: Amplitude of Angle

Search Result 438, Processing Time 0.03 seconds

Correlations Among Objective Measurements of Spasticity in Patients With Brain Lesions

  • Kim, Yong-Wook
    • Physical Therapy Korea
    • /
    • v.14 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • The purpose of this study was to investigate correlations among objective measurements of spasticity in patients with brain lesions. Thirty-two stroke and traumatic brain injury subjects participated in the study. Spasticity was quantified using the knee first flexion angle, relaxation index obtained from a pendulum drop test, and the amplitude of a knee tendon reflex test. Pearson's product correlation coefficient was used to examine relationships among these measurements of spasticity. There was a significant positive correlation between the relaxation index and knee first flexion angle in patients with brain lesions (r=.895, p<.01). There was also significant negative correlation between the amplitude of knee tendon reflex and relaxation index (r=-.612, p<.01), and between amplitude and knee first flexion angle (r=-.537, p<.01). Thus, it is possible to use the knee first flexion angle as an objective measure of spasticity, rather than relaxation index, which is more complicated to obtain. Further studies are needed to explore the effects of functional improvement and long-lasting carryover effects of spasticity using a simple objective measure such as the knee first flexion angle from a pendulum test.

  • PDF

Study on the Characteristics and Separating Performance of Oscillating Sieve for Optimization of Separating Losses of Combine (콤바인 선별손실(選別損失) 적정화(適正化)를 위(爲)한 요동(揺動)체의 특성(特性)과 선별성능(選別性能)에 관한 연구(硏究))

  • Kim, Sang Hun;Nam, Sang Il;Ryu, Su Nam
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.48-57
    • /
    • 1984
  • To analyze the grain transport velocity, which is valuable for optimizing the separation losses, an oscillating appratus for sieve was designed. The grain transport velocity was measured in each combination of three amplitude levels, three rpm levels and four projection angle levels. To analyze the grain transport velocity theortically, two computer programs were developed. And the results from experiment and theoretical analysis were compared. 1. The grain transport velocity was increased with the projection angle of oscillating sieve. Especially when the projection angle is higher than $45^{\circ}$ the grain transport velocity on the flat-plate was not increased but on the racked surface was increased persistently. 2. The grain transport velocity was increased linearly with the frequency of oscillating motion. The speed of driving link must be higher than 350 rpm at 24mm amplitude, 250 rpm at 36 mm amplitude to transport the grain efficiently. 3. The grain transport velocity was increased with the amplitude of oscillating motion. But if the amplitude was smaller than interval of racks, the grain on the racked surface was not transported, even though the projection angle or the speed of revolutionary link was increased. 4. The transport characteristics of a grain varied with the amplitude and projection angle. Especially in the range of 1.5 < K < 2.3 at $45^{\circ}$ projection angle the transportation of grain was successful and the grain motion consisted of sliding movement (forward, backward) and jumping movement, which is considered recommendable for separating process of a combine sieve. 5. The results from theoretical analysis were approximately in accord with that from experiment.

  • PDF

Ac Hysteresis Loop Depending on the Phase Angle of the Higher Harmonic Induction

  • derac Son;Eun Kyoung Kim
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.90-93
    • /
    • 1996
  • For the design of high efficiency electric machines, analysis of higher harmonic frequency components of the magnetic induction is necessary. We have measured ac magnetic properties of non-oriented silicon steel under harmonic frequencies ranging from $3^rd$ (180 Hz) to $9^th$(540 Hz) and harmonic amplitude components from 10% to 50% of the total amplitude ($B_max$=1.5T). From the experiment, it is found that, if the magnetic induction waveform has above $9^th$ harmonic frequency components of the magnetic induction, the core losses only depended on the harmonic amplitude component, but if harmonic frequency becomes lower than 9th harmonic frequency, the core losses depend on the phase angle and the harmonic amplitude, and phase angle should be considered in the design of electric machine.

  • PDF

Software Resolver-to-Digital Converter for Compensation of Amplitude Imbalances using D-Q Transformation

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1310-1319
    • /
    • 2013
  • Resolvers are transducers that are used to sense the angular position of rotational machines. The analog resolver is necessary to use resolver to digital converter. Among the RDC software method, angle tracking observer (ATO) is the most popular method. In an actual resolver-based position sensing system, amplitude imbalance dominantly distorts the estimate position information of ATO. Minority papers have reported position error compensation of resolver's output signal with amplitude imbalance. This paper proposes new ATO algorithm in order to compensate position errors caused by the amplitude imbalance. There is no need premeasured off line data. This is easy, simple, cost-effective, and able to work on line compensation. To verify feasibility of the proposed algorithm, simulation and experiments are carried out.

Inter-Rater Reliability of Quantitative Knee Tendon Reflex Test for Healthy Subjects (정상 성인에 대한 정량적 무릎힘줄반사 검사의 측정자간 신뢰도)

  • Kim, Yong-Wook;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.57-63
    • /
    • 2007
  • The purpose of this study was to evaluate inter-rater reliability of the amplitude and first knee extension angles in deep tendon reflex test by using an electrical hammer. Twenty-five healthy adults participated in the study. Compound muscle action potential is elicited by tapping the knee tendon with an electrical hammer in deep tendon reflex tests. The amplitude and knee extension angle were simultaneously measured. The mean value of the amplitude and the knee extension angles through three time trials for each tester, are used for determining the inter-rater and Intra-class Correlation Coefficients (ICCs) reliabilities. According to the results, the ICCs of the amplitude is .280 and that of the knee extension angle is .789. Pearson correlation coefficients of the amplitude of the action potential and the knee extension angles are .685, showing significant statistically moderate correlation. Inter-rater reliability in the amplitude was not significant. More objective and quantitative deep tendon reflex tests should be done to obtain higher reliability in further studies.

  • PDF

Wall Shear Stress Between Compliant Plates Under Oscillatory Flow Conditions: Influence of Wall Motion, Impedance Phase Angle and Non-Newtonian Fluid (맥동유동하에 있는 유연성 있는 평판 사이의 벽면전단응력: 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choe, Ju-Hwan;Lee, Jong-Seon;Kim, Chan-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.18-28
    • /
    • 2001
  • The present study investigates flow dynamics between two dimensional compliant plates under sinusoidal flow conditions in order to understand influence of wall motion, impedance phase angle (time delay between pressure and flow waveforms), and non-Newtonian fluid on wall shear stress using computational fluid dynamics. The results showed that wall motion induced additional terms in the streamwise velocity profile and the pressure gradient. These additional terms due to wall motion reduced the amplitude of wall shear stress and also changed the mean wall shear stress. The trend of the changes was very different depending on the impedance phase angle. As the impedance phase angle was changed to more negative values, the mean wall shear stress decreased while the amplitude of wall shear stress increased. As the phase angle was reduced from 0°to -90°under $\pm$4% wall motion, the mean wall shear stress decreased by 12% and the amplitude of wall shear stress increased by 9%. Therefore, for hypertensive patients who have large negative phase angles, the ratio of amplitude and mean of the wall shear stress is raised resulting in a more vulnerable state to atherosclerosis according to the low and oscillatory shear stress theory. We also found that non-Newtonian characteristics of the blood protect atherosclerosis by decreasing the oscillatory shear index.

Effects of Medication and Deep Brain Stimulation on the Finger-tapping Speed and Amplitude of Parkinsonian Bradykinesia (파킨슨성 완서증의 손가락 마주치기 속도와 크기에 대한 약물과 뇌심부자극의 효과)

  • Kim, Ji-Won;Kwon, Yu-Ri;Park, Sang-Hoon;Eom, Gwang-Moon;Koh, Seong-Beom;Jang, Ji-Wan;Lee, Hye-Mi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • The purpose of this study is to investigate whether medication and deep brain stimulation (DBS) have differential effects on the speed and amplitude of bradykinesia in patients with Parkinson's disease (PD). Five PD patients with implanted DBS electrodes (age: $60.6{\pm}7.4yrs$, H&Y stage: $3.1{\pm}0.2$) participated in this study. FT (finger tapping) movement was measured using a gyrosensor system in four treatment conditions: Med (Medication)-off/DBS-off, Med-off/DBS-on, Med-on/DBS-off and Med-on/DBS-on. Quantitative measures representing average speed and amplitude of FT movement included root-mean-squared (RMS) angular velocity and RMS angle. One-way repeated measures ANOVA showed that RMS angular velocity of Med-on/DBS-on was significantly greater than those of Med-off/DBS-off and Med-off/DBS-on (p < 0.01) whereas RMS angle was not different among conditions (p = 0.06). Two way repeated measures ANOVA showed that only medication improved RMS angular velocity (p < 0.01), whereas both medication and DBS had no significant effect on RMS angle (p > 0.02). Effect size of RMS angular velocity was greater than that of RMS angle in both medication and DBS. This suggests that medication and DBS have differential effects on FT bradykinesia and velocity and amplitude impairments may be associated with different functional aspects in PD.

Effect of fractional order on energy ratios at the boundary surface of elastic-piezothermoelastic media

  • Kumar, Rajneesh;Sharma, Poonam
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.157-174
    • /
    • 2017
  • In the present investigation reflection and transmission of plane waves at an elastic half space and piezothermoelastic solid half space with fractional order derivative is discussed. The piezothermoelastic solid half space is assumed to have 6 mm type symmetry and assumed to be loaded with an elastic half space. It is found that the amplitude ratios of various reflected and refracted waves are functions of angle of incidence, frequency of incident wave and are influenced by the piezothermoelastic properties of media. The expressions of amplitude ratios and energy ratios are obtained in closed form. The energy ratios are computed numerically using amplitude ratios for a particular model of graphite and Cadmium Selenide (CdSe). The variations of energy ratios with angle of incidence are shown graphically. The conservation of energy across the interface is verified. Some cases of interest are also deduced from the present investigation.

Required Performance Analysis of Wavefront Distortion System against Monopulse Radar (모노펄스 레이더에 대한 전파왜곡 시스템의 요구 성능 분석)

  • Jang, Yeonsoo;Kim, Ghiback;Park, Jintae;Lee, Changhoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.577-580
    • /
    • 2016
  • One of the effective jamming methods to disturb monopulse radars is a wavefront distortion. Most well-known wavefront distortion is the cross eye technique which uses two transmitters. The cross eye can make angle error regardless of monopulse radar structure but high accuracies of phase and amplitude between two transmitters should be needed to make large angle error. Thus, the accuracies of phase and amplitude are essentially required performance parameters for implementation of wavefront distortion systems and the required values of accuracy is dependant on amount of angle error. In this paper, we derive expressions for minimum required values of phase difference and amplitude ratio according to amount of angle error and analyze the results.

A Design of Simple and Precision Direction Finder with a Combination of an Amplitude Measurement and Phase Measurement

  • Lim Joong-Soo
    • International Journal of Contents
    • /
    • v.1 no.2
    • /
    • pp.35-38
    • /
    • 2005
  • This paper describes a design of simple and precision direction finder that can be adapted to shipboard or mobile vehicles used for Electronic support measure, ELINT and radio signal monitoring systems. The direction finding technology has improved with monolithic integrated circuit, linear array antennas, and interferometer. Interferometer uses the phase-comparison principle and has a good direction finding accuracy but it has an ambiguity problem. We suggest a simple ambiguity solver using phase-comparison technology with amplitude-comparison principle. The direction finding device that has been designed by the suggested method has 0.7 degree RMS error in azimuth angle and 0.6 degree RMS error in elevation angle in 0.5 - 2.0 GHz.

  • PDF