• Title/Summary/Keyword: Amplitude detection

Search Result 445, Processing Time 0.027 seconds

Swell Effect Correction for the High-resolution Marine Seismic Data (고해상 해저 탄성파 탐사자료에 대한 너울영향 보정)

  • Lee, Ho-Young;Koo, Nam-Hyung;Kim, Wonsik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.240-249
    • /
    • 2013
  • The seismic data quality of marine geological and engineering survey deteriorates because of the sea swell. We often conduct a marine survey when the swell height is about 1 ~ 2 m. The swell effect correction is required to enhance the horizontal continuity of seismic data and satisfy the resolution less than 1 m. We applied the swell correction to the 8 channel high-resolution airgun seismic data and 3.5 kHz subbottom profiler (SBP) data. The correct sea bottom detection is important for the swell correction. To detect the sea bottom, we used maximum amplitude of seismic signal around the expected sea bottom, and picked the first increasing point larger than threshold value related with the maximum amplitude. To find sea bottom easily in the case of the low quality data, we transformed the input data to envelope data or the cross-correlated data using the sea bottom wavelet. We averaged the picked sea bottom depths and calculated the correction values. The maximum correction of the airgun data was about 0.8 m and the maximum correction of two kinds of 3.5 kHz SBP data was 0.5 m and 2.0 m respectively. We enhanced the continuity of the subsurface layer and produced the high quality seismic section using the proper methods of swell correction.

Analysis of Trace Copper Metal at The Electrode Consisting of Carbon Nanotube using Stripping Voltammetry (벗김전압전류법을 이용한 카본나노튜브 전극에서의 구리 분석)

  • Choi, Chang-Kun;Jung, Young-Sam;Kim, Nack-Joo;Pak, Dae-Won;Chung, Kun-Yong;Kim, Lae-Hyun;Kwon, Yong-Chai
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.933-937
    • /
    • 2012
  • In the present study, we evaluate the sensitivity and optimal stripping voltammetry (SV) conditions of copper (Cu), which is one of the main trace heavy metals inducing the environmental contamination, using carbon nanotube (CNT) electrode. In addition, the reaction mechanism of stripping reaction of Cu is investigated. The electrochemical analyses such as squarewave stripping voltammetry (SWSV) and linear scan voltammetry (LSV) are used for the evaluations. As a result of that, the best SWSV conditions like squarewave amplitude of 15 mV, frequency of 60 Hz, deposition potential of -1.0V vs. Ag/AgCl and deposition time of 200s are determined with the measured Cu sensitivity of $1.824{\mu}A/{\mu}M$. As a driving force affecting the stripping reaction of Cu, surface reaction is more dominant one than diffusion. These results are compared with other reference results and it is confirmed that our suggested CNT electrode gives rise to better Cu sensitivity result than other references.

Depiction of Acute Stroke Using 3-Tesla Clinical Amide Proton Transfer Imaging: Saturation Time Optimization Using an in vivo Rat Stroke Model, and a Preliminary Study in Human

  • Park, Ji Eun;Kim, Ho Sung;Jung, Seung Chai;Keupp, Jochen;Jeong, Ha-Kyu;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. Materials and Methods: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a $B_{1,rms}$ amplitude of $1.2{\mu}T$ using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. Results: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at $1.2{\mu}T$ power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. Conclusion: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the $1.2{\mu}T$ power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.

Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes (SG Tube 축방향 노치 균열의 정량적 EC 신호평가)

  • Min, Kyong-Mahn;Park, Jung-Am;Shin, Ki-Seok;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.374-382
    • /
    • 2009
  • Steam generator(SG) tube, as a barrier isolating primary to the secondary coolant system of nuclear power plants(NPP), must maintain the structural integrity far the public safety and its efficient power generation capacity. And SG tubes bearing defects must be timely detected and taken repair measures if needed. For the accomplishment of these objectives, SG tubes have been periodically examined by eddy current testing(ECT) on the basis of administrative notices and intensified SG management program(SGMP). Stress corrosion cracking(SCC) on the SG tubes is not easily detected and even missed since it has lower signal amplitude and other disturbing factors against its detection. However once SCC is developed, that can cause detrimental affects to the SG tubes due to its rapid propagation rate. Accordingly SCC is categorized as prime damage mechanism challenging the soundness of the SG tubes. In this study, reproduced EDM notch specimens are examined for the detectability and quantitative characterization of the axial ODSCC by +PT MRPC probe, containing pancake, +PT and shielded pancake coils apart in a single plane around the circumference. The results of this study are assumed to be applicable fur providing key information of engineering evaluation of SCC and improvement of confidence level of ECT on SG tubes.

Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal (펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정)

  • Ha, Job;Jhang, Kyung-Young;Sasaki, Kimio;Tanaka, Hiroaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • Ultrasonic nonlinearity has been considered as a solution for the detection of microcracks or interfacial delamination in a layered structure. The distinguished phenomenon in nonlinear ultrasonics is the generation of higher-order harmonic waves during the propagation. Therefore, in order to quantify the nonlinearity, the conventional method measures a parameter defined as the amplitude ratio of a second-order harmonic component and a fundamental frequency component included in the propagated ultrasonic wave signal. However, its application In field inspection is not easy at the present stage because no standard methodology has yet been made to accurately estimate this parameter. Thus, the aim of this paper is to propose an advanced signal processing technique for the precise estimation of a nonlinear ultrasonic parameter, which is based on power spectral and bispectral analysis. The method of estimating power spectrum and bispectrum of the pulse-like ultrasonic wave signal used in the commercial SAM (scanning acoustic microscopy) equipment is especially considered in this study The usefulness of the proposed method Is confirmed by experiments for a Newton ring with a continuous air gap between two glasses and a real semiconductor sample with local delaminations. The results show that the nonlinear parameter obtained tv the proposed method had a good correlation with the delamination.

THREE-SITE PHOTOMETRIC MONITORING OF THE δ SCT-TYPE PULSATING STAR V1162 ORIONIS : PERIOD CHANGE AND ITS IMPLICATIONS FOR PRE-MAIN SEQUENCE EVOLUTION

  • KIM, SEUNG-LEE;CHA, SANG-MOK;LIM, BEOMDU;LEE, JAE WOO;LEE, CHUNG-UK;LEE, YONGSEOK;KIM, DONG-JIN;LEE, DONG-JOO;KOO, JAE-RIM;HONG, KYEONGSOO;RYU, YOON-HYUN;PARK, BYEONG-GON
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.5
    • /
    • pp.199-208
    • /
    • 2016
  • We present photometric results of the δ Sct star V1162 Ori, which is extensively monitored for a total of 49 nights from mid-December 2014 to early-March 2015. The observations are made with three KMTNet (Korea Microlensing Telescope Network) 1.6 m telescopes installed in Chile, South Africa, and Australia. Multiple frequency analysis is applied to the data and resulted in clear detection of seven frequencies without an alias problem: five known frequencies and two new ones with small amplitudes of 1.2-1.7 mmag. The amplitudes of all but one frequency are significantly different from previous results, confirming the existence of long-term amplitude changes. We examine the variations in pulsation timings of V1162 Ori for about 30 years by using the times of maximum light obtained from our data and collected from the literatures. The O − C (Observed minus Calculated) timing diagram shows a combination of a downward parabolic variation with a period decreasing rate of (1/P)dP/dt = −4.22 × 10−6 year−1 and a cyclic change with a period of about 2780 days. The most probable explanation for this cyclic variation is the light-travel-time effect caused by an unknown binary companion, which has a minimum mass of 0.69 M. V1162 Ori is the first δ Sct-type pulsating star of which the observed fast period decrease can be interpreted as an evolutionary effect of a pre-main sequence star, considering its membership of the Orion OB 1c association.

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF

Arrhythmia Classification Method using QRS Pattern of ECG Signal according to Personalized Type (대상 유형별 ECG 신호의 QRS 패턴을 이용한 부정맥 분류)

  • Cho, Ik-sung;Jeong, Jong -Hyeog;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1728-1736
    • /
    • 2015
  • Several algorithms have been developed to classify arrhythmia which either rely on specific ECG(Electrocardiogram) database. Nevertheless personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. But it is difficult to detect the P and T wave signal because of person's individual difference. Therefore it is necessary to design efficient algorithm that classifies different arrhythmia in realtime and decreases computational cost by extracting minimal feature. In this paper, we propose arrhythmia classification method using QRS Pattern of ECG signal according to personalized type. For this purpose, we detected R wave through the preprocessing method and define QRS pattern of ECG signal by QRS feature Also, we detect and modify by pattern classification, classified arrhythmia duplicated QRS pattern in realtime. Normal, PVC, PAC, LBBB, RBBB, Paced beat classification is evaluated by using 43 record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.98%, 97.22%, 95.14%, 91.47%, 94.85%, 97.48% in PVC, PAC, Normal, BBB, Paced beat classification.

Terahertz Generation and Detection Using InGaAs/InAlAs Multi Quantum Well

  • Park, Dong-U;Han, Im-Sik;No, Sam-Gyu;Ji, Yeong-Bin;O, Seung-Jae;Seo, Jin-Seok;Jeon, Tae-In;Kim, Jin-Su;Kim, Jong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.205-205
    • /
    • 2013
  • 테라헤르쯔(terahertz: THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지 (meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자 이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한 (low-temperature grown : LT) GaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 현재 THz 응용분야에서 보다 작고 가격경쟁력이 있는 광통신을 이용한 THz photomixer등이 활발히 연구 하고 있다. 광섬유 내에서 손실과 분산이 최소값을 가지는 부분이 1.55 ${\mu}m$ 부근이고 In0.53Ga0.47As 기판을 이용하였을 때 여기에 완벽하게 만족하게 된다. 하지만 LT-InGaAs 의 경우 AsGa antisite로 인하여 carrier lifetime은 짧아지지만 높은 n-type 전하밀도를 가지게 된다. 이때 Be을 doping하여 전하밀도를 보상하여 높은 저항을 유지해야 하는데 Be의 활성화를 위해서는 열처리를 필요로 한다. 하지만 열처리를 하면 carrier lifetime이 길어지기 때문에 carrier lifetime과 저항을 적절히 조율해야 한다. 이는 물질자체의 특성이기 때문에 InGaAs는 GaAs보다 낮은 amplitude와 짧은 cut-off frequency를 가진다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 InGaAs:Be/InAlAs multi quantum well (MQW)를 온도별 ($250{\sim}400^{\circ}C$), 주기별 (50~150)로 성장을 하였고 이때 InGaAs layer의 Be doping level은 $2{\times}1018\;cm^{-3}$, Ex-situ annealing은 $550^{\circ}C$에서 10분으로 고정 하였다. THz 발생 실험에서는 InGaAs/InAlAs MQW은 4000 pA로 1,000 pA를 가지는 InGaAs epilayer보다 4배 높은 전류 신호를 얻을 수 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. THz 검출 실험에서는 LT-InGaAs:Be epilayer LT-InGaAs:Be/InAlAs, HT-InGaAs/InAlAs 샘플이 각각 180, 9000, 12000 pA의 전류신호를 가지고 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. HT-InGaAs/InAlAs MQW를 이용한 검출실험에서는 InGaAs layer가 defect free이지만 LT-InGaAs:Be/ InAlAs MQW 보다 높은 전류 신호를 얻을 수 있었다. 이는 InAlAs layer가 저항만 높이는 것뿐만 아니라 carrier trapping layer로써의 역할도 하는 것으로 사료된다.

  • PDF

Laboratory Experiments for Evaluating Necking Defects in Bored Piles Embedded in Sandy Soils Using Electromagnetic Waves (전자기파를 이용한 모래 지반에 설치된 현장타설말뚝의 네킹 결함 평가를 위한 실내 모형실험)

  • Lee, Jong-Sub;Kim, Youngdae;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.5
    • /
    • pp.25-34
    • /
    • 2020
  • Studies on nondestructive evaluation methods using electromagnetic waves have been commonly conducted to evaluate necking defects in bored piles. However, the propagation of electromagnetic waves are affected by water contents of surrounding materials. This study aims to investigate a suitability of electromagnetic waves for evaluating necking defects in bored piles embedded in sandy soils through laboratory experiments. Laboratory experiments are performed with a model pile having a necking defect. The diameter and length of model pile are 600 mm and 1 m, respectively, and the model pile is embedded in sandy soils with different water contents of 10%, 20%, and 30%. For the propagation of electromagnetic waves, a transmission line is configured in reinforcement cage using an electrical wire. The generation and detection of electromagnetic waves are conducted using a time domain reflectometer. Experimental results show that the peak amplitude of electromagnetic waves reflected at the necking defect decreases with an increase in the water content in sandy soils. In addition, the velocity of electromagnetic waves reflected from the toe of the model pile decreases win an increase in the water content. However, estimated locations of the necking defects are almost the same to that of the actual location of the necking defect. This study demonstrates that electromagnetic waves may be an effective method for evaluating necking defects in bored piles embedded in sandy soils