• Title/Summary/Keyword: Amplitude detection

Search Result 446, Processing Time 0.032 seconds

Study of seismic amplitude method using single source for tunnel detection (터널탐사에 단일 파동원을 이용한 탄성파 진폭법에 관한 연구)

  • Suh, Baek-Soo;Sohn, Kwon-Ik
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.3-7
    • /
    • 2007
  • There are many techniques to calculate the exact position of deep seated tunnel. Especially, tomography method has been used generally in present days. This method has been performed mainly by wave traveltime. Because of short interval of two measuring boreholes, it was very hard to interpret the exact tunnel position. To solve this problem, seismic amplitude method was tried to detect exact pososition of tunnel in this study.

  • PDF

A Study on Prediction of Treeting Breakdown in XLPE Cable According to Method of Acoustic Emission Detection (음향방출 계측법에 따른 가교폴리에틸렌 케이블의 트리잉 파괴 예지에 관한 연구)

  • 김재환;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.4
    • /
    • pp.26-33
    • /
    • 1993
  • The acoustic emission automatic detection system is developed to observe tree deterioration phenomena. Applying an alternating voltage of 15(kVnns) toXLPE tree specimens, many pulses of small amplitude are detected when the bush type tree developes branch type and a few pulses of high amplitude prcxluced as branch type propagated to bush type tree. Therefore, it is known that pulses having small amplitude operates as a destructive factor. It is observed that the skewness of the amplitude and the number of average pulses as distribution tendency of three dimension are characteristic quantity of AE pulses. As the trajectory of skewness is farther from the origin on the S-plane, it is more likely to breakdown.

  • PDF

Detection of Pesticide Thiram in Plant Leafs Using Voltammetric at Nanotube Electrode (나노튜브전극을 사용한 전압전류법에 의한 식물잎에서 살충제 검출)

  • Lee, Chang-Hyun;Ly, Suw-Young
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1335-1341
    • /
    • 2010
  • Voltammetric diagnostics of pesticide thiram was studied in plant leafs in vivo fluid with DNA immobilized on a carbon nanotube electrode (DCE). Sensor properties of carbon nanotube (CE) and DNA immobilized nanotube were compared. DCE was more effective than CE in target detecting. The parameters such as pH strength, stripping accumulation, amplitude, and increment potential were examined to find the optimum condition for detection of pesticide thiram in a sesame leaf. The optimized conditions were as follows 550 Hz frequency, 0.15 V amplitude, 0.005 V increment potential, -1.2 V initial potential, 4.78 pH, 500 sec accumulation time. Under optimum condition, the detection limit of thiram was attained at 0.01ng/L.

Mechanically Fabricated Defects Detection on Underwater Steel Pipes using Ultrasonic Guided Waves (유도초음파를 이용한 수중 강관의 기계적 결함 검출)

  • Woo, Dong-Woo;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.140-145
    • /
    • 2010
  • This study presents a detection method for mechanically fabricated defects on underwater steel pipes, using ultrasonic guided waves. Three different diameters (60, 90, and 114 mm) of 1000-mm long steel pipes were considered, along with several experimental design factors such as incident angles, incident distances, and the degrees of defects, to investigate how these factors affected the experimental results - the detectability of the mechanical defects. From the experimental results, we determined that the amplitude and arrival time of the first received wave signals gave a promising clue for distinguishing the existence of the defects and their severities. Between the amplitude and arrival time, the arrival time gave a more promising indication since it was affected by the experimental factors in a constant manner. Therefore, it was shown that the use of ultrasonic guided waves for underwater pipe inspection is feasible.

In-Process Detection of Flank Wear Width by AE Signals When Machining of ADI (ADI 절삭시 AE신호에 의한 플랭크 마멸폭의 인프로세스 검출)

  • 전태옥
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.71-77
    • /
    • 1999
  • Monitoring of Cutting tool wear is a critical issue in automated machining system and has been extensively studied for many years. An austempered ductile iron(ADI) exhibits the excellent mechanical properties and the wear resistance. ADI has generally the poor machinability due to the characteristic. This paper presents the in-process detection of flank wear of cutting tools using the acoustic emission sensor and the digital oscilloscope. The amplitude level of AE signal(AErms) is mainly affected by cutting speed and it is proportional to cutting speed. There have been the relationship of direct proportion between the amplitude level of AE signals and the flank wear width of cutting tool. The flank wear with corresponding to the tool life is successfully detected with the monitor-ing system used in this study.

  • PDF

A High Impedance Fault Detection Algorithm Using Wavelet Transform (Wavelet 변환을 이용한 배전 계통의 고 저항 사고 검출 알고리즘)

  • Nam, S.R.;Kang, Y.C.;Kim, S.S.;Sohn, J.M.;Park, J.K.;Jang, S.I.;Kim, K.H.;Kim, I.D.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.975-978
    • /
    • 1997
  • This Paper presents a high impedance fault (HIF) detection algorithm of distribution systems using wavelet transform. Two HIFs on dry soil and sandy soil were simulated on various load conditions in 22.9 kV distribution systems using EMTP, and the current wavelets were decomposed by wavelet transform. The current root mean square(rms) change, the index change rate and the relative amplitude change were used as the multi-criteria for a HIF detection. The index change rate and the relative amplitude were made using the wavelet coefficients.

  • PDF

A Mothod for Detection of Vibrationi by the Ultrasonic (초음파를 이용한 진동의 검출방법)

  • 이백영;서호선;차일환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.65-69
    • /
    • 1982
  • It is studied on the apparatus for detecting the amplitude and the frequency of the vidrating object by utilizing the Ultrasonic Doppler Effect, without having any effect on the vibratioinal cases. The output detected varing the distance between the transducers and the vibrating object, when the angles of the incidence and the reflection wave are equalized. AM demodulatioin is adapted for the detection of vibration, and the output errors are theoretically consideed. The accurate detection of vibration can be obtained, when the distance between them is 5cm to 20cm, the magnitude of amplitude is 1mm to 5mm, and the vibrational frequency range is 20Hz to 1KHz.

  • PDF

Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method (압전형 수신 기법을 이용한 초음파 절대변위진폭 측정)

  • Park, Seong-Hyun;Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

A Review of Change Detection Techniques using Multi-temporal Synthetic Aperture Radar Images (다중시기 위성 레이더 영상을 활용한 변화탐지 기술 리뷰)

  • Baek, Won-Kyung;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_1
    • /
    • pp.737-750
    • /
    • 2019
  • Information of target changes in inaccessible areas is very important in terms of national security. Fast and accurate change detection of targets is very important to respond quickly. Spaceborne synthetic aperture radar can acquire images with high accuracy regardless of weather conditions and solar altitude. With the recent increase in the number of SAR satellites, it is possible to acquire images with less than one day temporal resolution for the same area. This advantage greatly increases the availability of change detection for inaccessible areas. Commonly available information in satellite SAR is amplitude and phase information, and change detection techniques have been developed based on each technology. Those are amplitude Change Detection (ACD), Coherence Change Detection (CCD). Each algorithm differs in the preprocessing process for accurate automatic classification technique according to the difference of information characteristics and the final detection result of each algorithm. Therefore, by analyzing the academic research trends for ACD and CCD, each technologies can be complemented. The goal of this paper is identifying current issues of SAR change detection techniques by collecting research papers. This study would help to find the prerequisites for SAR change detection and use it to conduct periodic detection research on inaccessible areas.

Development of Leak Detection System of Heat Exchanger using Acoustic Emission Technique (음향방출기법을 이용한 열교환기 누설검출시스템 개발)

  • Lee, Min-Rae;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.864-871
    • /
    • 2002
  • Acoustic emission(AE) technique has been applied to not only mechanical property testing but also on-line monitoring of the entire structure or a limit zone only. Although several AE devices have already been developed for on-line monitoring, the price of these systems is very high and it is difficult for the field to apply yet. In this study, we developed a specially designed PC-based leak detection system using A/D board. In this paper, AE technique has been applied to detect leak for heat exchanger by analyzing the characteristics of signal obtained from leak. It was confirmed that the characteristics of the signal generated by the turbulence of gas in the heat exchanger is narrow band signal having between 130-250kHz. Generally, the amplitude of leak signal is increased as the leak size increasing, but showed no significant change at frequency characteristic. Leak source location can be found by determining for the paint of highest signal amplitude by comparing with several fixed sensors. In this paper, AE results are compared with the PC-based leak detection system using A/D board.