• Title/Summary/Keyword: Amplitude compression

Search Result 93, Processing Time 0.021 seconds

A Novel Measurement Approach for the Half-wave Voltage of Phase Modulator based on PM-MZI Photonic Link

  • Xianghua, Li;Chun, Yang;Quanyi, Ye;Yuhua, Chong;Zhenghua, Zhou
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.288-291
    • /
    • 2014
  • This paper presents a new method for measuring the half-wave voltage $V_{\pi}$ of an electro-optic phase modulator based on a phase-modulated photonic link with interferometric demodulation. By using this method, the $V_{\pi}$ can be obtained with the RF voltage amplitude input required to achieve 1-dB gain compression of link and the differential delay of a Mach-Zehnder interferometer. We measure the $V_{\pi}$ of a commercial phase modulator by using the presented method and the carrier/the first sideband intensity ratio method. Furthermore, we compare the two measurements with the typical value provided by the manufacturer. The experiment shows that this novel measurement method is feasible, straightforward, and accurate.

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

A "deformable section" model for the dynamics of suspension bridges -Part II: Nonlinear analysis and large amplitude oscillations

  • Sepe, Vincenzo;Diaferio, Mariella;Augusti, Giuliano
    • Wind and Structures
    • /
    • v.6 no.6
    • /
    • pp.451-470
    • /
    • 2003
  • The classical two-degree-of-freedom (2-d-o-f) "sectional model" is of common use to study the dynamics of suspension bridges. It takes into account the first pair of vertical and torsional modes of the bridge and describes well global oscillations caused by wind actions on the deck, yielding very useful information on the overall behaviour and the aerodynamic and aeroelastic response; however, it does not consider relative oscillations between main cables and deck. On the contrary, the 4-d-o-f model described in the two Parts of this paper includes longitudinal deformability of the hangers (assumed linear elastic in tension and unable to react in compression) and thus allows to take into account not only global oscillations, but also relative oscillations between main cables and deck. In particular, when the hangers go slack, large nonlinear oscillations are possible; if the hangers remain taut, the oscillations remain small and essentially linear: the latter behaviour has been the specific object of Part I (Sepe and Augusti 2001), while the present Part II investigates the nonlinear behaviour (coexisting large and/or small amplitude oscillations) under harmonic actions on the cables and/or on the deck, such as might be generated by vortex shedding. Because of the discontinuities and strong nonlinearity of the governing equations, the response has been investigated numerically. The results obtained for sample values of mechanical and forcing parameters seems to confirm that relative oscillations cannot a priori be excluded for very long span bridges under wind-induced loads, and they can stimulate a discussion on the actual possibility of such phenomena.

Microfailure Degradation Mechanisms and Interfacial Properties of Bioabsorbable Composites for Implant Materials using Micromechanical Technique and Acoustic Emission (Micromechanical 시험법과 음향방출을 이용한 Implant용 Bioabsorbable 복합재료의 미세파괴 분해메커니즘과 계면물성)

  • 박종만;김대식
    • Composites Research
    • /
    • v.14 no.4
    • /
    • pp.15-26
    • /
    • 2001
  • Interfacial properties and microfailure degradation mechanisms of the bioabsorbable composites fur implant materials were investigated using micromechanical technique and nondestructive acoustic emission (AE). As hydrolysis time increased, the tensile strength, the modulus and the elongation of poly(ester-amide) (PEA) and bioactive glass fibers decreased, whereas these of chitosan fiber almost did not change. Interfacial shear strength (IFSS) between bioactive glass fiber and poly-L-lactide (PLLA) was much higher than PEA or chitosan fiber/PLLA systems using dual matrix composite (DMC) specimen. The decreasing rate of IFSS was the fastest in bioactive glass fiber/PLLA composites whereas that of chitosan fiber/PLLA composites was the slowest. AE amplitude and AE energy of PEA fiber decreased gradually, and their distributions became narrower than those in the initial state with hydrolysis time. In case of bioactive glass fiber, AE amplitude and AE energy in tensile failure were much higher than in compression. In addition, AE parameters at the initial state were much higher than those after degradation under both tensile and compressive tests. In this work, interfacial properties and microfailure degradation mechanisms can be important factors to control bioabsorbable composite performance.

  • PDF

An adaptive digital watermark using the spatial masking (공간 마스킹을 이용한 적응적 디지털 워터 마크)

  • 김현태
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.9 no.3
    • /
    • pp.39-52
    • /
    • 1999
  • In this paper we propose a new watermarking technique for copyright protection of images. The proposed technique is based on a spatial masking method with a spatial scale parameter. In general it becomes more robust against various attacks but with some degradations on the image quality as the amplitude of the watermark increases. On the other hand it becomes perceptually more invisible but more vulnerable to various attacks as the amplitude of the watermark decreases. Thus it is quite complex to decide the compromise between the robustness of watermark and its visibility. We note that watermarking using the spread spectrum is not robust enought. That is there may be some areas in the image that are tolerable to strong watermark signals. However large smooth areas may not be strong enough. Thus in order to enhance the invisibility of watermarked image for those areas the spatial masking characteristics of the HVS(Human Visual System) should be exploited. That is for texture regions the magnitude of the watermark can be large whereas for those smooth regions the magnitude of the watermark can be small. As a result the proposed watermarking algorithm is intend to satisfy both the robustness of watermark and the quality of the image. The experimental results show that the proposed algorithm is robust to image deformations(such as compression adding noise image scaling clipping and collusion attack).

Object-based digital watermarking methods in frequency domain (주파수 영역에서의 객체기반 디지털 워터마크)

  • Kim, Hyun-Tae;Kim, Dae-Jin;Won, Chee-Sun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.5
    • /
    • pp.9-20
    • /
    • 2000
  • In this paper we compare two frequency domain digital watermarking methods for digital Images, namely DCT(Discrete Cosine Transform) based and DFT(Discrete Fourier Transform) based methods. Unlike DCT coefficients, which always have real values, DFT coefficients normally have complex values Therefore, the DFT coefficients have amplitude and phase components Among them, the phase components are known to carry more Important information for the Images. So, we insert the watermark to the phase of the DFT coefficients only This DFT watermarking method is compared with the conventional DCT based watermarking method for the object-based watermarking problem. Experimental results show that the DFT-phase based method IS more robust to general Image processing attacks including resize, lossy compression(JPEG), blurring and median filtering. On the other hand, the DCT based method is more robust to the malicious attack which inserts different watermarks.

  • PDF

The Low Probability of Intercept RADAR Waveform Based on Random Phase and Code Rate Transition for Doppler Tolerance Improvement (도플러 특성 개선을 위한 랜덤 위상 및 부호율 천이 기반 저피탐 레이다 파형)

  • Lee, Ki-Woong;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.999-1011
    • /
    • 2015
  • In modern electronic warfare, RADAR is under constant threat of ECM(Electronic Counter Measures) signals from nearby jammers. The conventional linear frequency modulated(Linear-FM) waveform is easy to be intercepted to estimate its signal parameters due to its periodical phase transition. Recently, APCN(Advanced Pulse Compression Noise) waveform using random amplitude and phase transition was proposed for LPI(Low probability of Intercept). But random phase code signals such as APCN waveform tend to be sensitive to Doppler frequency shift and result in performance degradation during moving target detection. In this paper, random phase and code rate transition based radar waveform(RPCR) is proposed for Doppler tolerance improvement. Time frequency analysis is carried out through ambiguity analysis to validate the improved Doppler tolerance of RPCR waveform. As a means to measure the vulnerability of the proposed RPCR waveform against LPI, WHT(Wigner-Hough Transform) is adopted to analyze and estimate signal parameters for ECCM(Electronic Counter Counter Measures) application.

Compressive performance of RAC filled GFRP tube-profile steel composite columns under axial loads

  • Ma, Hui;Bai, Hengyu;Zhao, Yanli;Liu, Yunhe;Zhang, Peng
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.335-349
    • /
    • 2019
  • To investigate the axial compressive performance of the recycled aggregate concrete (RAC) filled glass fiber reinforced polymer (GFRP) tube and profile steel composite columns, static loading tests were carried out on 18 specimens under axial loads in this study, including 7 RAC filled GFRP tube columns and 11 RAC filled GFRP tube-profile steel composite columns. The design parameters include recycled coarse aggregate (RCA) replacement percentage, profile steel ratio, slenderness ratio and RAC strength. The failure process, failure modes, axial stress-strain curves, strain development and axial bearing capacity of all specimens were mainly analyzed in detail. The experimental results show that the GFRP tube had strong restraint ability to RAC material and the profile steel could improve the axial compressive performance of the columns. The failure modes of the columns can be summarized as follow: the profile steel in the composite columns yielded first, then the internal RAC material was crushed, and finally the fiberglass of the external GFRP tube was seriously torn, resulting in the final failure of columns. The axial bearing capacity of the columns decreased with the increase of RCA replacement percentage and the maximum decreasing amplitude was 11.10%. In addition, the slenderness ratio had an adverse effect on the axial bearing capacity of the columns. However, the strength of the RAC material could effectively improve the axial bearing capacity of the columns, but their deformability decreased. In addition, the increasing profile steel ratio contributed to the axial compressive capacity of the composite columns. Based on the above analysis, a formula for calculating the bearing capacity of composite columns under axial compression load is proposed, and the adverse effects of slenderness ratio and RCA replacement percentage are considered.

Tight sportswear and physiological function - Effect on muscle strength and EMG activity -

  • Dai, Xiao-Qun;Li, Yu-Ping;Cai, Juan-Juan;Lu, A-Ming;Wang, Guo-Dong
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.4
    • /
    • pp.606-611
    • /
    • 2013
  • It has been reported that tight sportswear could have complicated influence on physiological function of human body. The purpose of this present study was to investigate the effect of wearing gradient compression tights (GCT) on muscle strength and EMG activity during repeated isokinetic muscle contractions. Four healthy male undergraduate students performed maximal voluntary isokinetic concentric muscle contractions on biomechanical test and training systems with GCT and loose pants as control (Cont) respectively. During each test, the peak torque of extensor and flexor contractions and the surface electromyography (sEMG) of the rectus femoris and medial gastrocnemius was recorded simultaneously, the peak torque was recorded as an indicator of muscle strength, and the average amplitude and mean power frequency of sEMG were calculated as indicators of EMG activity. The results showed that: the peak torque decreased gradually during continuous muscle contractions both when the Cont and GCT were worn, average sEMG and mean power frequency declined along with the repetitions of muscle contractions for both wearing conditions, and the change tendency was consistence with that of peak torque. There was no obvious difference between the peak torque recorded wearing the Cont or wearing GCT, but when GCT were worn, average sEMG was lower and mean power frequency was higher than the Cont condition. In 24 samples obtained from four subjects, 80% of results showed the same trend. So we could make a conclusion that wearing GCT had no obvious effect on the improvement of muscle strength, but it would affect the EMG activity positivly.

ECG Signal Compression using Feature Points based on Curvature (곡률을 이용한 특징점 기반 심전도 신호 압축)

  • Kim, Tae-Hun;Kim, Sung-Wan;Ryu, Chun-Ha;Yun, Byoung-Ju;Kim, Jeong-Hong;Choi, Byung-Jae;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.624-630
    • /
    • 2010
  • As electrocardiogram(ECG) signals are generally sampled with a frequency of over 200Hz, a method to compress diagnostic information without losing data is required to store and transmit them efficiently. In this paper, an ECG signal compression method, which uses feature points based on curvature, is proposed. The feature points of P, Q, R, S, T waves, which are critical components of the ECG signal, have large curvature values compared to other vertexes. Thus, these vertexes are extracted with the proposed method, which uses local extremum of curvatures. Furthermore, in order to minimize reconstruction errors of the ECG signal, extra vertexes are added according to the iterative vertex selection method. Through the experimental results on the ECG signals from MIT-BIH Arrhythmia database, it is concluded that the vertexes selected by the proposed method preserve all feature points of the ECG signals. In addition, they are more efficient than the AZTEC(Amplitude Zone Time Epoch Coding) method.