• Title/Summary/Keyword: Amplitude Image

Search Result 274, Processing Time 0.025 seconds

Performance Analysis of TH-BPPM and TH-BPAM UWB System and the Applications in Data and Image Transmission

  • Sung, Tae-Kyung
    • Journal of Navigation and Port Research
    • /
    • v.31 no.2
    • /
    • pp.159-163
    • /
    • 2007
  • In this paper, we mainly analyze the performance of two ultra wideband communication systems, the classical Time Hopping Binary Pulse Position Modulation (TH-BPPM) UWB system and the Time Hopping Bipolar Pulse Amplitude Modulation (TH-BPAM) UWB system. The performance of TH-BPPM and TH-BPAM is analyzed in detail under an ideal AWGN channel and a correlation receiver. We use the power spectral density function to get the expression of BER of these two UWB systems. It yields simple and exact formulas relating the performance to the system parameters. The analysis shows that TH-BPPM suffers performance degradation with respect to TH-BPAM. Furthermore, we give the computer simulation of both data and image transmission and our simulation results also prove our theoretical analysis.

Automatic Crack Detection on Pressed Panels Using Camera Image Processing with Local Amplitude Mapping (카메라 이미지 처리를 통한 프레스 패널의 크랙결함 검출)

  • Lee, Chang Won;Jung, Hwee Kwon;Park, Gyuhae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.451-459
    • /
    • 2016
  • Crack detection on panels during manufacturing process is an important step for ensuring the product quality. The accuracy and efficiency of traditional crack detection methods, which are performed by eye inspection, are dependent on human inspectors. Therefore, implementation of an on-line and precise crack detection is required during the panel pressing process. In this paper, a regular CCTV camera system is utilized to obtain images of panel products and an image process based crack detection technique is developed. This technique uses a comparison between the base image and a test image using an amplitude mapping of the local image. Experiments are performed in the laboratory and in the actual manufacturing lines to evaluate the performance of the developed technique. Experimental results indicate that the proposed technique could be used to effectively detect a crack on panels with high speed.

Detection of a Point Target Movement with SAR Interferometry

  • Jun, Jung-Hee;Ka, Min-ho
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.4
    • /
    • pp.355-365
    • /
    • 2000
  • The interferometric correlation, or coherence, is calculated to measure the variance of the interferometric phase and amplitude within the neighbourhood of any location within the image at a result of SAR (Synthetic Aperture Radar) interferometric process which utilizes the phase information of the images. The coherence contains additional information that is useful for detecting point targets which change their location in an area of interest (AOI). In this research, a RGB colour composite image was generated with a intensity image (master image), a intensity change image as a difference between master image and slave image, and a coherence image generated as a part of SAR interferometric processing. We developed a technique performing detection of a point target movement using SAR interferometry and applied it to suitable tandem pair images of ERS-1 and ERS-2 as test data. The possibility of change detection of a point target in the AOI could be identified with the technique proposed in this research.

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

A Study on Lohmann Type Computer Generated Holograms Using a Circular Cell (원형 셀을 이용한 Lohmann형 컴퓨터 형성 홀로그램에 관한 연구)

  • Seo, Choon-Su;Jeong, Man-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.6
    • /
    • pp.519-524
    • /
    • 2006
  • In general, the Lohmann-type binary hologram represents its amplitude and phase by using the rectangular cell. In this paper, we adapts a circular cell to represents the amplitude and phase of holograms. In order to compare the characteristics of the circular cell with the rectangular one, we analyzed the results based on the computer simulations and various optical experiments. The results show that a clearer reconstructed image can be obtained by dividing one cell into many pixels. In the case of a uniform reconstructed image, the rectangular cell is better than the circular cell. However, as for the brightness of the reconstructed image, the circular cell is better than the rectangular one.

Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan (방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰)

  • Bom, Hee-Seung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

Improvement of Two-Dimensional Terahertz Image by Digital Image Processing (데이터 처리를 통한 테라헤르츠 (THz) 파의 2차원 이미지 개선)

  • Shon, Chae-Hwa;Jin, Yun-Sik;Jeon, Seuk-Gy;Kim, Keun-Ju;Jung, Sun-Shin;Yong, Chong-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.500-507
    • /
    • 2005
  • Two-dimensional (2D) images that are produced by terahertz (THz) irradiation we presented. It is possible to obtain 2D image of various materials by observing the amplitude and the phase of the THz signals which go through them. Better images are produced by combining the amplitude and phase of the signal rather than using only one of these. Homomorphic filtering that is one elf the well-known technique of digital image signal processing is effective to reduce the noise signal and can provide better quality images. The results can be applied to real-time imaging afterwards.

Diffraction Amplitude Distribution of Finite Gaussian Pupil with Residual Aberrations (잔류수차가 있는 유한 가우스 동의 회절진폭 분포)

  • 송영란;이민희;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.142-145
    • /
    • 1998
  • It is shown that the optical system with Gaussian pupil e, diffraction amplitude distribution is not affected by the presence of residual aberrations. The case of spherical aberration is treated, as an example, and the complex diffraction amplitude distribution at the neighbourhood of the image point is described analytically by using a recurrence formula.

  • PDF

Analysis on Phase and Amplitude Apodization in SIL Based Near-Field Recording Optics (SIL 응용 광 기록계에서 발생하는 위상 및 진폭 Apodization 해석)

  • Kim Wan-Chin;Choe Hyeon;Song TaeSun;Park No-Cheol;Park Young-Pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.14-15
    • /
    • 2005
  • In near-field recording (NFR) optics using solid immersion lens (SIL), near-field air gap induces unwanted spherical aberration, defocus and astigmatism. This phenomenon can be explained with the apodization of phase and amplitude between each linearly polarized light. In this paper, we analyzed the effect of phase and amplitude apodization with the fundamental multiple beam interference theory, and we compared resultant diffracted patterns on the image plane for the Si-disk first surface media structure and cover-layer incident media structure.

  • PDF