• 제목/요약/키워드: Ammonia-refrigerator

검색결과 18건 처리시간 0.026초

확산형 흡수식 냉장고의 사이클 해석 (Cycle Analysis of Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향 (Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

공기 압축기와 암모니아 냉동기의 진동 분석 사례 (Case study of the Vibration Analysis of the Compressor Ammonia Refrigerator)

  • 장용석;임장익;김병수;김효중;최병근
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.52-56
    • /
    • 2008
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. Because vibration diagnosis can avoid sudden breakdown of machine and reduce the maintenance costs. In chemical factory, Air-compressor and refrigerator which can affect the performance and capacity of output are important machine. Therefore, in this paper, the vibration of reassembled air-compressor and refrigerator after explosion is measured for checking the machine condition. The result of diagnosis and solution is discussed in this paper.

  • PDF

암모니아/물 흡수식 냉동기의 수직원관형 흡수기의 동적 모델 (Dynamic Model of a Vertical Tube Absorber for Ammonia/water Absorption Refrigerators)

  • 문현석;정은수;김병주
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.844-853
    • /
    • 2002
  • A dynamic model which simulates the coupled heat and mass transfer within a vertical tube absorber was developed. The liquid film is a binary mixture of two components, and both of these components are present in the vapor phase. The pressure, concentration, temperature and mass flow rate of the vapor are obtained by assuming that the pressure is uniform within an absorber. The model was applied to an absorber for an ammonia/water absorption refrigerator. The transient behaviors of the pressure, the outlet temperature and the concentration of the solution and the cooling water outlet temperature on a step change at the absorber inlet of the cooling water temperature, the vapor mass flow rate and the concentration of the solution were shown.

암모니아/물 흡수식 냉동기의 대향류 판형 재생기의 수치모델

  • 지제환;정은수;정시영
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.1034-1041
    • /
    • 2001
  • A numerical model which simulates the flow boiling process of the ammonia/water solution within a plate type generator for ammonia/water absorption refrigerators was developed. The ammonia/water solution flows downward under gravity and the ammonia/water vapor generated by flow boiling flows upward. The heating medium flows counter to the ammonia/water solution. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phases were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the heating medium inlet temperature, the mass flow rate of the heating medium and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석 (Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators)

  • 지제환;정은수;정시영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

연소기 후치 가스터빈에 관한 열역학적 연구 (A Thermodynamic Study on Exhaust Heated Gas Turbine Cycle)

  • 박종구;오수철;양옥룡
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.18-28
    • /
    • 1994
  • An exhaust-heated gas turbine cycle equipped with a waste heat recovery boiler and ammonia absorption-type refrigerator using waste heat is newly devised and analyzed. The general performance of this cycle is compared with that of the conventional gas turbine cycle. This cycle shows a potential high efficiency. When 1500K of gas turbine inlet temperature the efficiency is 53 percent as compared to 45 percent for a conventional combined cycle. Suction cooling of this cycle leads to improve the thermal efficiency and the specific output.

  • PDF

공기 압축기와 암모니아 냉동기의 진동 측정 및 분석 (Vibration Measurement and Analysis of Air compressor and Ammonia Refrigerator)

  • 장용석;정재환;정한얼;최병근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1015-1019
    • /
    • 2007
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. Because vibration diagnosis can avoid sudden breakdown of machine and reduce the maintenance costs. In chemical factory, Air-compressor and refrigerator which can affect the performance and capacity of output is important machine. Therefore, in this paper, the vibration of reassembled air-compressor and refrigerator after explosion is measured for checking the machine condition. The result of diagnosis and solution is discussed in this paper.

  • PDF

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF