• Title/Summary/Keyword: Ammonia sensor

Search Result 70, Processing Time 0.025 seconds

Ammonia gas sensing characteristics of LaFeO3 thick-films With Al2O3 additives (Al2O3를 첨가한 LaFeO3 후막의 암모니아 가스 감지특성)

  • Kim, Jun-Gon;Ahn, Byeong-Yeol;Ma, Tae-Young;Park, Ki-Cheol;Kim, Jeong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.18-27
    • /
    • 2002
  • $LaFeO_3$-based thick films with 2wt.%, 5wt.% and 10wt.% $Al_2O_3$ additives were fabricated by screen printing method on $Al_2O_3$ substrates. Structural, electrical and ammonia gas sensing characteristics of the thick films with different heat treatment temperatures were examined. From XRD results, the compound of $LaFeO_3$ and $Al_2O_3$ was not found until the heat treatment at $1200^{\circ}C$. SEM microphotograph showed similar grain growth despite the amount of $Al_2O_3$ additives with the heat treatment. Thick films with high activation energy and low resistance in the electrical properties showed high sensitivity for gases. Thick films with 2wt % $Al_2O_3$ additives heat-treated at $1200^{\circ}C$ showed the sensitivities of 210% for 100 ppm $NH_3$ gas at the working temperature of $350^{\circ}C$. The thick films showed food selectivity to $NH_3$ gas.

Measuring the Environment of Pig Houses (돈사의 환경계측에 관한 연구)

  • 최규홍;손재룡;이강진;최동수;최용삼;남상일
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.155-164
    • /
    • 2001
  • Environmental factors such as $NH_3,\;H_2S,\;CO_2$, dust, temperature, and humidity in the animal house are a potential health hazard to humans and animals. Until now, most of measurement methods can only provide periodic results with low accuracy. A data acquisition system which can measure continuously and simultaneously $NH_3,\;H_2S,\;CO_2$, temperature, and humidity was developed and installed in two pig houses. Daily changes of environment for the pig-houses were investigated by the data acquisition system. In order to evaluate NH$_3$sensor, gas samples were obtained and NH$_3$concentrations were measured at nine positions; combinations of three positions(inlet, middle, and outlet) and three heights(0 cm, 40 cm, 150 cm). Ammonia concentration of 14.0 ~37.1 ppm for slurry pig-house is higher than that of 8.4~29.7 ppm for scraper pig-house, and there were no statistical differences among the positions. However, the concentration of $NH_3$at 150 cm was higher than thats of 0 cm and 40 cm.

  • PDF

The Development and Implementation of Model-based Control Algorithm of Urea-SCR Dosing System for Improving De-NOx Performance and Reducing NH3-slip (Urea-SCR 분사시스템의 DeNOx 저감 성능 향상과 NH3 슬립저감을 위한 모델 기반 제어알고리즘 개발 및 구현)

  • Jeong, Soo-Jin;Kim, Woo-Seung;Park, Jung-Kwon;Lee, Ho-Kil;Oh, Se-Doo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.95-105
    • /
    • 2012
  • The selective catalytic reduction (SCR) system is a highly-effective aftertreatment device for NOx reduction of diesel engines. Generally, the ammonia ($NH_3$) was generated from reaction mechanism of SCR in the SCR system using the liquid urea as the reluctant. Therefore, the precise urea dosing control is a very important key for NOx and $NH_3$ slip reduction in the SCR system. This paper investigated NOx and $NH_3$ emission characteristics of urea-SCR dosing system based on model-based control algorithm in order to reduce NOx. In the map-based control algorithm, target amount of urea solution was determined by mass flow rate of exhaust gas obtained from engine rpm, torque and $O_2$ for feed-back control NOx concentration should be measured by NOx sensor. Moreover, this algorithm can not estimate $NH_3$ absorbed on the catalyst. Hence, the urea injection can be too rich or too lean. In this study, the model-based control algorithm was developed and evaluated on the numerical model describing physical and chemical phenomena in SCR system. One channel thermo-fluid model coupled with finely tuned chemical reaction model was applied to this control algorithm. The vehicle test was carried out by using map-based and model-based control algorithms in the NEDC mode in order to evaluate the performance of the model based control algorithm.

Determination of L-Asparagine Using Proteus mirabilis Bacterial Electrode (Proteus mirabilis 박테리아 전극을 이용한 L-Asparagine의 정량)

  • Ihn Gwon-Shik;Moo-Jeong Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.422-427
    • /
    • 1988
  • The bio-electrode for L-asparagine, excellent in the reproducibility of responsibility, has been constructed by immobilizing the bacterium Proteus mirabilis on an ammonia gas sensor. This electrode was investigated for the effects of pH, temperature, buffer solution, bacterial amounts and interferences, and stability with the lapse of time. The response of the bacterial electrode was linear in the range of $9.0{\times}10^{-5}$$1.0{\times}10^{-2}M$ L-asparagine with a slope of 58.9mV/decade in pH 7.8, 0.05M phosphate buffer solution at $30^{\circ}C$. The bacterial amounts used for this electrode was 3 mg and response time was 7∼9 min. Therefore, this assembly can be used for the determination of L-asparagine.

  • PDF

Worker Symptom-based Chemical Substance Estimation System Design Using Knowledge Base (지식베이스를 이용한 작업자 증상 기반 화학물질 추정 시스템 설계)

  • Ju, Yongtaek;Lee, Donghoon;Shin, Eunji;Yoo, Sangwoo;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.9-15
    • /
    • 2021
  • In this paper, a study on the construction of a knowledge base based on natural language processing and the design of a chemical substance estimation system for the development of a knowledge service for a real-time sensor information fusion detection system and symptoms of contact with chemical substances in industrial sites. The information on 499 chemical substances contact symptoms from the Wireless Information System for Emergency Responders(WISER) program provided by the National Institutes of Health(NIH) in the United States was used as a reference. AllegroGraph 7.0.1 was used, input triples are Cas No., Synonyms, Symptom, SMILES, InChl, and Formula. As a result of establishing the knowledge base, it was confirmed that 39 symptoms based on ammonia (CAS No: 7664-41-7) were the same as those of the WISER program. Through this, a method of establishing was proposed knowledge base for the symptom extraction process of the chemical substance estimation system.

Development and Evaluation of Portable Multiple Gas Meter (휴대용 다중 가스측정 장비 개발 및 평가)

  • Jang, Hee-Joong;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.483-490
    • /
    • 2019
  • Assessing the effect of forest fires and measuring the gas concentration around a fire has received little attention. Therefore, the concentrations of various gases in areas surrounding a fire need to be measured by the development of a suitable device. Unlike conventional portable devices, the AQS (Air Quality System) proposed in this paper is a portable instrument that measures five types of gases simultaneously, including CO, CO2, NOx, VOCs, and NH3, and has high durability through sensor protection algorithms. A PC-based program with an AQS connection was developed to monitor the real-time changes in the gas concentration. The reliability of the developed device was proven through a comparison of the results with other commercial gas analyzers. Measurements of the concentration due to indoor and outdoor fires were performed around a fire area to review the applicability and the predicted results were obtained.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Gas Sensing Characteristics of $SnO_{2}$ added with $TiO_{2},\;Pd,\;Pt$ and in for Trimethylamine Gas (Trimethylamine Gas 측정을 위한 $TiO_{2},\;Pd,\;Pt$ 및 In이 첨가된 $SnO_{2}$가스 센서의 특성)

  • Lee, Chang-Seop;Jung, Soon-Boon;Jun, Jae-Mok;Lee, In-Sun;Lee, Hyeong-Rag;Park, Young-Ho;Choi, Sung-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.29-33
    • /
    • 2007
  • This study investigates the use of $TiO_{2},\;Pd,\;Pt$, and In which greatly improves a sensitivity to trimethylamine gas. The metal-$SnO_{2}$ thick films were prepared by screen-printing method onto $Al_{2}O_{3}$ substrates with platinum electrode. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box as a function of detecting gas concentration. This was then used to detect trimethylamine, dimethylamine, and ammonia vapours within the concentration range of 100-1000ppm. The gas sensing properties of metal-$SnO_{2}$ mixed thick films depended on the content and variety of metal. It was found that sensitivity and selectivity of the films dopped with 1 wt% Pd and 10 wt% $TiO_{2}$ for trimethylamin gas showed the best result at $250^{\circ}C$.

  • PDF

Fabrication and Characteristics of ZnO-based thin film sensors with high selectivity for TMA gas (TMA 가스 선택성 향상을 위한 ZnO계 박막센서의 제작 및 특성)

  • Park, Sung-Hyun;Choi, Woo-Chang;Kim, Sung-Woo;Ryu, Jee-Youl;Choi, Hyek-Hwan;Lee, Myong-Kyo;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.36-43
    • /
    • 2000
  • In oder to enhance the selectivity of TMA(trimethylamine) gas, the ZnO-based films which were doped with $Al_2O_3$, $TiO_2, $In_2O_3$ and $V_2O_5$ catalysts with various weight percents were deposited in oxygen by RF magnetron sputtering method. To improve electrical stability of sensors, the ZnO-based films were annealed in oxygen at $700^{\circ}C$ for 1 hour. The TMA selectivity of sensors was defined by the magnitude($S_{TMA}/S_{DMA}$ and $S_{TMA}/S_{NH3}$) of TMA sensitivity relative to DMA and sensitivity ammonia($NH_3$) sensitivity, respectively. The $ZnO+Al_2O_3(4\;wt.%)+TiO_2(1\;wt.%)+In_2O_3(1\;wt.%)$ sensor showed high $S_{TMA}/S_{DMA}$ of 5.9 and $S_{TMA}/S_{NH3}$ of 26 to 160 ppm at the working temperature of $300^{\circ}C$ respectively.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.