• 제목/요약/키워드: Ammonia fluxes

검색결과 11건 처리시간 0.017초

액상 황산철(liquid ferrous sulfate)을 육계 깔짚에 처리시 암모니아 발생량, pH및 총 질소 함량 변화 (Changes in Ammonia Fluxes, pH and Total Nitrogen in Liquid Ferrous Sulfate-treated Litter)

  • 정태호
    • 한국환경과학회지
    • /
    • 제28권2호
    • /
    • pp.287-290
    • /
    • 2019
  • This study investigates the changes in ammonia fluxes, pH and total nitrogen of liquid ferrous sulfate-treated litter over 5 weeks. A total of 200 broiler chicks (Arbor Acres, 1 d old) was separated into two treatment groups (0 g and 100 g liquid ferrous sulfate/kg litter) with four replications of 25 birds in each group. Liquid ferrous sulfate was sprayed on the litter by using a small sprayer. There was no difference (p>0.05) in the ammonia fluxes observed between the control and liquid ferrous sulfate treatment groups at 0, 1, and 5 weeks, except for 2, 3 and 4 weeks. At 5 weeks, the litter pH and total nitrogen content did not show any difference (p>0.05) between the control and liquid ferrous sulfate treatment groups. In conclusion, the use of liquid ferrous sulfate is not a suitable for use in poultry litter to reduce ammonia and pH or improve the total nitrogen content.

수직원관형 GAX 흡수기 내부의 열 및 물질전달과정에 대한 수치모델 (A Numerical Model for Heat and Mass Transfer Processes within a Vertical Tube GAX Absorber)

  • 천태식;정은수
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.102-111
    • /
    • 2000
  • A numerical model which simulates the simultaneous heat and mass transfer within a vertical tube GAX absorber was developed. The ammonia vapor and the solution liquid are in counter-current flow, and the hydronic fluid flows counter to the solution liquid. The film thickness and the velocity distribution of the liquid film were obtained by matching the shear stress at the liquid-vapor interface. Two-dimensional diffusion and energy equations were solved in the liquid film to give the temperature and concentration, and a modified Colburn-Drew analysis was used for the vapor phase to determine the heat and mass fluxes at the liquid-vapor interface. The model was applied to a GAX absorber to investigate the absorption rates, temperature and concentration profiles, and mass flow rates of liquid and vapor phases. It was shown that the mass flux of water was negligible compared with that of ammonia except the region near the liquid inlet. Ammonia absorption rate increases rapidly near the liquid inlet and decrease slowly. Both the absorption rate of ammonia vapor and the desorption rate of water near the liquid inlet increase as the vapor mass flow rate increases, but the mass fluxes of the ammonia and the water near the liquid outlet decrease as the mass flow rate of the vapor increases.

  • PDF

하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발 (Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants)

  • 사재환;전의찬;정재학
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.

Atmosphere-forest Exchange of Ammoniacal Nitrogen in a Subalpine Deciduous Forest in Central Japan during a Summer Week

  • Hayashi, Kentaro;Matsuda, Kazuhide;Takahashi, Akira;Nakaya, Ko
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권2호
    • /
    • pp.134-143
    • /
    • 2011
  • The present study aimed to investigate the diurnal variations in air concentrations and exchange fluxes of ammoniacal nitrogen ($NH_x$: ammonia ($NH_3$) and particulate ammonium) in a subalpine deciduous forest in central Japan during a week in summer. The $NH_3$ concentrations ($0.50\;{\mu}g\;N\;m^{-3}$ on average) showed a clear circadian variation, i.e., high and low in the daytime and nighttime, respectively. The concentration of particulate ammonium in the coarse fractions was extremely low, whereas that for the PM2.5 fraction was relatively high $0.55\;{\mu}g\;N\;m^{-3}$ on average). The main inorganic ion components of PM2.5 at the study site were ammonium and sulfate. The exchange fluxes of $NH_x$ were bidirectional. Both the maximum and minimum values occurred in the daytime, i.e., $0.39\;mg\;N\;m^{-2}\;hr^{-1}$ of downward flux and $0.11\;mg\;N\;m^{-2}\;hr^{-1}$ of upward flux for $NH_3$ and $0.25\;mg\;N\;m^{-2}\;hr^{-1}$ of downward flux and $0.13\;mg\;N\;m^{-2}\;hr^{-1}$ of upward flux for PM2.5 ammonium. The exchange fluxes of $NH_x$ at night could be considered as zero. The mean deposition velocity during the research period was almost zero for both $NH_3$ and PM2.5 ammonium. The atmosphere-forest exchange of $NH_x$ in the forest during the study period was balanced. The remarkably large deposition of $NH_x$ was attributable to meteorological events such as showers the night before that thoroughly washed the forest canopy and subsequent clear skies in the morning, which enhanced convection. The cleaning effect of rainfall and the rapid change in convection in the early morning should be monitored to evaluate and generalize the gas and particle exchange in a forest.

환경정화곤충의 활용이 한우분에 미치는 영향 (Effects of Using Environmental Purification Insects on Hanwoo Manure)

  • 김정연
    • 한국환경과학회지
    • /
    • 제32권9호
    • /
    • pp.671-674
    • /
    • 2023
  • This study was conducted to evaluate the effects of using Hermetia illucens larvae as environmental purification insects on ammonia and Hanwoo manure for 15 days in the Hanwoo farms. H.illucens larvae were allocated into four treatment groups and three replicates using a randomized block design. The treatments were as follows: control, normal 1000 g of Hanwoo manure, T1, 1000 g of Hanwoo manure + 100 g of 2nd instar H.illucens L. larvae, T2, 1000 g of Hanwoo manure + 100 g of 3rd instar H.illucens L. larvae, and T3, 1000 g of Hanwoo manure + 100 g of 4th instar H.illucens L. larvae. After 0 days, ammonia fluxes did not occur in the 2nd, 3rd, and 4th instar H.illucens larvae treatments (p<0.05). Among the characteristics of Hanwoo manure, the pH and nitrogen content increased for each larvae instar of H.illucens, whereas ADF and NDF content decreased (p<0.05). In particular, nitrogen contents were found to be highest in the 3rd instar larvae of H.illucens owing to their greater ability to decompose Hanwoo manure than larvae at other growth stages.

서낙동강 하구에서 퇴적물과 강물 경계면을 통한 질산염의 플럭스 (Nitrate Flux at the Sediment-Water Interface in the West-Nakdong River Estuary)

  • 이태희;이동섭
    • Ocean and Polar Research
    • /
    • 제26권4호
    • /
    • pp.635-646
    • /
    • 2004
  • Chronic outbreaks of green tide in the Nakdong estuary toll a heavy socioeconomic cost. The paper investigates the influence of sediments on the nitrogen eutrophication, being claimed as the primary cause of green tide. To measure the flux of nitrate at the sediments-water interface, sediment cores were taken in Jan., Mar., May and Sep., 2000 at Noksan located in the West-Nakdong river estuary. The dissolved oxygen was profiled and then the pore water was extracted in situ. Core samples were analyzed for their textural characteristics. Cores were incubated by a novel technique to measure the fluxes of nitrate $(NO_3^-)$ and ammonia $(NH_4^+)$ at the sediment-water interface. The dissolved oxygen was depleted usually within several millimeters in the top sediments. Nitrate started to decrease drastically at the layer where dissolved oxygen was nearly depleted. Nitrate was also exhausted within several centimeters, followed by ammonia build up rapidly. The flux at the sediments-water interface calculated from the pore water concentrations revealed that nitrate was removed from the water column into the sediments. The sediment incubation experiment confirmed the above result. On the other hand ammonia were released from the sediment to the water column. As the incubation went on, however, the nitrate concentration in the overlying water was dropped below that of a top sediment. Then the flux is reversed, i.e., nitrate was released from the sediments to the water column. The implication is that the sediment can supply nitrate to the water column if it falls below a certain level. Thus it is likely that sediments in the eutrophicated river buffers the nitrate concentration in the water column, which leads to a prolonged green tide.

팔당호로의 질소와 황성분 침적 측정 (Measurement of Nitrogen and Sulfur Deposition to Lake Paldang)

  • 김영성;진현철
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.39-48
    • /
    • 2005
  • Nitrogen and sulfur deposition was measured on Lake Pal dang from March 2002 to October 2003. Wet and dry depositions were separately measured using wet- and dry-only samplers, respectively. In order to measure the dry deposition to the water body, a dry deposition sampler composed of three pans filled with pure water, called the deposition water, was used. Since ammonium was generally in excess in ambient air, more than half of ammonium was present in the gaseous form. Ammonium concentration was also generally higher than the sum of major anion concentrations in the deposition water because gaseous species were much easily deposited than the species in fine particles. Nevertheless, the contribution of gaseous ammonia to the deposition of ammonium was not high as well as that of particulate ammonium while the contribution of gaseous nitric acid was much higher than that of particulate nitrate. Annual wet deposition fluxes of nitrogen and sulfur were five and six times higher than their dry deposition fluxes, respectively. Except for ammonium, the dry deposition flux estimated in the present work was a half of the previous results. This was mainly caused by much smaller dry deposition velocities over the water than over the ground.

시화호에서 암모니아와 납의 저층용출 (Benthic Fluxes of Ammonia and Lead in Lake Shihwa)

  • 한명우;박용철;허성회
    • 한국해양학회지:바다
    • /
    • 제2권2호
    • /
    • pp.69-77
    • /
    • 1997
  • 염분약층으로 발달한 강력한 성층에 의해 저염분-유산소의 표층수와 고염분-무산소의 저층수로 분리된 시화호의 한 정점에서 퇴적물을 시추하였다. 공극수 암모니아와 납은 매우 높은 농도로 분포하여, 암모니아는 퇴적깊이 9cm에서 1420 ${\mu}M$에 이르고 낚은 3 cm에서 최대 농도 1348 nM에 이른다. 환원상태에서 안정한 암모니아와 납의 고 농도분포는 성층으로 형성된 저층수와 퇴적층의 무산소 환경이 심각한 상태임을 시사한다. 저층수의 고립은 저층용출에 의한 저층수의 수질오염 가능성을 제시한다. 암모니아의 총 저층용출량과 저층수의 암모니아 총량으로부터 저층수의 암모니아 체류시간을 3.1년로 유도하였는데, 이 시간은 방조제 완공후 조사 당시까지의 경과시간 2.5년과 거의 일치한다. 두 시간의 일치는 적어도 암모니아에 대해서 저층수의 수질오염이 대부분 시화호 바닥 퇴적물에서 발원하는 저층용출에 의해 진행되고 있음을 시사한다. 저층수 납의 체류시간은 20일 정도로 상당히 빠르게 나타나는데, 이것은 퇴적물에서 저층수로 용출된 납이 곧바로 침전되어 퇴적물로 돌아옴을 시사한다. 저층수의 높은 황화수소 농도와 쇄설성 입자의 높은 침강량은 납황화물 형태의 침전 가능성을 높여준다.

  • PDF

해수-퇴적물 경계면을 지나는 우라늄 제거 과정과 플럭스 연구: 생지화학적 접근 (Processes and Fluxes of Uranium Removal Across the Sediment-Water Interface: A Biogeochemical Approach)

  • 김기현;조진형;이재성
    • 한국해양학회지:바다
    • /
    • 제4권3호
    • /
    • pp.188-197
    • /
    • 1999
  • 해수에서 퇴적층으로 향하는 우라늄 제거 과정과 플럭스를 연구하기 위해 1996년 10월 16일과 1997년 8월 25일에 천수만 입구지역에서 공극수와 해저상자(benthic chamber, BC) 내부시료를 채취하였다. 공극수로부터 추정된 우라늄 플럭스는 해수~퇴적물 경계면에서 0.112~0.566 mg/$m^2yr$ 이었으며, 해수에서 퇴적물로 제거되는 양상을 보였다. 황해 전체로는 $4.3{\sim}21.5{\times}10^7$ g/yr의 우라늄이 제거되며 이는 전지구적 제거 플럭스의 0.4~2.2%에 달하는 값이다. 같은 방법으로 추정된 영양영 플럭스는 암모니아성 질소 135.6 mmol/$m^2yr$, 질산성 질소 228.2 mmol/$m^2yr$, 인산염 36.8 mmol/$m^2yr$, 그리고 규산염 23.9 mmol/$m^2yr$로 공극수에서 저층 해수로 용출되고 있다. 공극수중 질산성 질소와 퇴적물 망간의 수직 분포도로부터 산화환원 경계층이 퇴적물 표충하 3~5 cm 깊이에 존재함을 추정할 수 있었다. BC를 이용한 인산염 플럭스는 28.5 mmol/$m^2yr$로서 공극수를 통한 추정값과 비슷하였다. 반면에 BC를 이용한 우라늄과 규산염 플럭스 추정치는 공극수에 의한 값보다 두 자릿수 정도로 큰 값을 나타내었다. 공극수내 농도 분포로부터 추정된 우라늄과 영양염의 플럭스 추정치가 BC를 통한 추정치보다 더욱 신뢰도가 높다고 판단된다.

  • PDF

Exhaust Plasma Characteristics of Direct-Current Arcjet Thrusters

  • Tahara, Hirokazu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.327-334
    • /
    • 2004
  • Spectroscopic and electrostatic probe measurements were made to examine plasma characteristics with or without a metal plate for a 10-㎾-class direct-current arcjet Heat fluxes into the plate from the plasma were also evaluated with a Nickel slug and thermocouple arrangement. Ammonia and mixtures of nitrogen and hydrogen were used. The NH$_3$ and $N_2$+3H$_2$ plasmas in the nozzle and in the downstream plume without a plate were in thermodynamical nonequilibrium states. As a result, the H-atom electronic excitation temperature and the $N_2$ molecule-rotational excitation temperature intensively decreased downstream in the nozzle although the NH molecule-rotational excitation temperature did not show an axial decrease. Each temperature was kept in a small range in the plume without a plate except for the NH rotational temperature for NH$_3$ gas. On the other hand, as approaching the plate, the thermodynamical nonequilibrium plasma came to be a temperature-equilibrium one because the plasma flow tended to stagnate in front of the plate. The electron temperature had a small radial variation near the plate. Both the electron number density and the heat flux decreased radially outward, and an increase in H$_2$ mole fraction raised them at a constant radial position. In cases with NH$_3$ and $N_2$+3H$_2$ a large number of NH radical with a radially wide distribution was considered to cause a large amount of energy loss, i.e., frozen flow loss, for arcjet thrusters.

  • PDF