• Title/Summary/Keyword: Ammonia/water

Search Result 953, Processing Time 0.03 seconds

A Study on Treatment of Livestock wastewater using Fenton Oxidation and Zeolite Adsorption Process (Fenton 산화공정과 Zeolite 흡착공정을 연계한 축산폐수처리에 관한 연구)

  • Cho, Chang-Woo;Kim, Youn-Jeong;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.505-510
    • /
    • 2005
  • The objective of this study was to remove non-biodegradable matters and ammonia ion in livestock wastewater using Fenton oxidation and Zeolite adsorption process. After coagulation process as 1st treatment, non-biodegradable matters remained after 1st treatment were removed by using OH radical produced in Fenton oxidation process. Zeolite as cation adsoption process was used to remove ammonia ion in 2nd treatment water. As a result of treatment using these processes, NBDCOD removal efficiency was over 90% and ammonia ion was almost removed. Most aromatics or polynuclear aromatics like benzene, phenol and scatol in livestock wastewater wasn't detected after Fenton oxidation process.

Fine Structure and Physical Properties of Cotton Fibers and their Fabrics Treated with Liquid Ammonia, NaOH, and NaOH/Liquid Ammonia (액체암모니아, 수산화나트륨, 수산화나트륨/액체암모니아 처리한 면의 미세구조 및 물성)

  • 배소영;이문철;김홍성;이영희;김경환
    • Textile Coloration and Finishing
    • /
    • v.6 no.2
    • /
    • pp.47-54
    • /
    • 1994
  • Cotton fiber, NaOH-mercerized cotton fiber, cotton fabric, and NaOH-mercerized cotton fabric have been treated by liquid ammonia at -33.4$^{\circ}C$. The fine structures, bending properties, tensile strengthes, shrinkages for laundering, and wrinkle recoveries were studied. The treatment of cottons with liquid ammonia brought about the transition of crystal lattice ; transforming cellulose I crystal of original cotton to cellulose I and III crystal, and cellulose II crystal of mercerized cotton to cellulose II and III crystals. The degree of crystallinities were decreased in the order of liquid ammonia>NaOH/liquid ammonia>NaOH-treated cotton. However moisture regain and water absorbency for liquid ammonia-treated cotton were lower than that of NaOH-treated cotton because of a difference in swelling actions of the agents. It seems caused by intermicrofibrillar pores produced in swelling processes. The bending rigidity and bending hysteresis were decreased remarkly by liquid ammonia treatment. Therefore softness and dimensional stability were improved. The liquid amminia and NaOH/liquid ammonia-treated cottons moreover show excellent properties in tensile strength, anti-shrinkage for laundering, and wrinkle recovery.

  • PDF

Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction (유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성)

  • 권경민;정시영;김병주;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

Enzyme Immobilized Reactor Design for Ammonia Removal from Waste Water

  • Song, Ju-Yeong;Chung, Soo-Bae
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.77-81
    • /
    • 1997
  • Removal of nitrogen compound from waste water is essential and often accomplished by biological process. To prevent washout and to develop an efficient bioreactor, immobilization of sutibal microorganisms could be sensible approach. Strains and permeabilized cell encapsulated in cellulose nitrate microcapsules and immobilized on polystyrene films were prepared by the method described in the previous study. In the wastewater treatment system, nitrification of ammonia component is generally known as rate controlling step. To enhance the rate of nitrification, firstly nitrifying strains Nitrosomonas europaea(IFO14298), are permeabilized chemically, and immobilized on polystyrene films and secondly oxidation rates of strain system and permeabilized strain system are compared in the same condition. with 30 minute permeabilized cells, it took about 25 hours to oxidize 70% of ammonia in the solution, while it took about 40 hours to treat same amount of ammonia with untreated cells. All the immobilization procedures did not harm to the enzyme activity and no mass transfer resistance through the capsule well was shown. In the durability test of immobilized system, the system showed considerable activity for the repeated operation for 90 days. With these results, the system developed in this study showed the possibility to be used in the actual waste water treatment system.

  • PDF

Characterization of Electrochemical Ammonia Electrolysis Using a Platinum Electrode for Anodic Reaction (Pt포일 양극을 이용한 전기화학적 암모니아 수전해 특성 연구)

  • CHOI, JEONGMIN;KIM, HAKDEOK;SONG, JUHUN
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.337-342
    • /
    • 2022
  • In this study, a water electrolysis was studied to investigate the effect of ammonia on current density and H2 gas production. A H type cell with three electrodes was used and KOH solution was used as electrolyte. The conventional platinum foil was used for working electrode, whereas nickel foam was used for counter electrode. CV experiment was performed to see the activity of ammonia oxidation reaction. In addition, CP experiment was done to examine the dependence of Faraday efficiency of hydrogen on current density and NH3 concentration. The CV result shows the 0.5M NH3 concentration required for highest current density and reliable operation. The CP result shows the increased current density leads to higher H2 generation. The higher H2 production and subsequent energy efficiency was observed for 0.5M NH3 using a Pt/13%Rh coil for a cathode as compared to those in water electrolysis.

Effect of Water on the Kinetics of Nitric Oxides Reduction by Ammonia over V-based Catalyst (바나듐계 촉매상에서 암모니아를 이용한 질소산화물의 환원반응속도에 수분이 미치는 영향에 관한 연구)

  • Kim, Young-Deuk;Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.73-82
    • /
    • 2012
  • The main and side reactions of the three selective catalytic reduction (SCR) reactions with ammonia over a vanadium-based catalyst have been investigated using synthetic gas mixtures in the temperature range of $170{\sim}590^{\circ}C$. The three SCR reactions are standard SCR with pure NO, fast SCR with an equimolar mixture of NO and $NO_2$, and $NO_2$ SCR with pure $NO_2$. Vanadium based catalyst has no significant activity in NO oxidation to $NO_2$, while it has high activity for $NO_2$ decomposition at high temperatures. The selective catalytic oxidation of ammonia and the formation of nitrous oxide compete with the SCR reactions at the high temperatures. Water strongly inhibits the selective catalytic oxidation of ammonia and the formation of nitrous oxide, thus increasing the selectivity of the SCR reactions. However, the presence of water inhibits the SCR activity, most pronounced at low temperatures. In this study, the experimental results are analyzed by means of a dynamic one-dimensional isothermal heterogeneous plug-flow reactor (PFR) model according to the Eley-Rideal mechanism.

Performance Analysis of a Combined Power Cycle Utilizing Low-Temperature Heat Source and LNG Cold Energy (저온 열원 및 LNG 냉열을 이용하는 복합 발전 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Oh, Jae-Hyeong;Ko, Hyung-Jong
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.382-389
    • /
    • 2012
  • Power generation cycle using ammonia-water mixture as working fluid has attracted much attention because of its ability to efficiently convert low-temperature heat source into useful work. If an ammonia-water power cycle is combined with a power cycle using liquefied natural gas (LNG), the conversion efficiency could be further improved owing to the cold energy of LNG at $-162^{\circ}C$. In this work parametric study is carried out on the thermodynamic performance of a power cycle consisted of an ammonia-water Rankine cycle as an upper cycle and a LNG cycle as a bottom cycle. As a driving energy the combined cycle utilizes a low-temperature heat source in the form of sensible heat. The effects on the system performance of the system parameters such as ammonia concentration ($x_b$), turbine 1 inlet pressure ($P_{H_1}$) and temperature ($T_{H_1}$), and condenser outlet temperature ($T_{L_1}$) are extensively investigated. Calculation results show that thermal efficiency increases with the increase of $P_{H_1}$, $T_{H_1}$ and the decrease of $T_{L_1}$, while its dependence on $x_b$ has a downward convex shape. The changes of net work generation with respect to $P_{H_1}$, $T_{H_1}$, $T_{L_1}$, and $x_b$ are roughly linear.

Removal of #NH_3-N$ by using Immobilized Nitrifier Consortium in Polyvinyl Alcohol (PVA에 고정화된 질화세균에 의한 암모니아성 질소제거)

  • 서근학;김용하;조진구;김병진;서재관;박은주;김성구
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.479-483
    • /
    • 1999
  • Nitrifier consortium immobilized in polyvinyl alcohol was used for the removal of ammonia nitrogen from synthetic aquaculture water in the airlift bioreactor. At the aeration rate fo 0.15 vvm and bead packing volume fraction of 20%, airlift bioreactor was operated effectively for a removal of ammonia nitrogen and for a stability of operation. Ammonia nitrogen removal rate by airlift bioreactor was continuously increased with decreasing hydraulic residence time. At the HRT(hydraulic residence time) of 0.3 hour, ammonia nitrogen removal rate was 84.3 g/$m^3$.d and the highest ammonia nitrogen removal rate was 130.8 g/$m^3$.d when HRT was 0.1 hour.

  • PDF

Development of Encapsulated Media for Ammonia Removal (암모니아 가스 제거를 위한 포괄고정화 담체 개발)

  • Jeong, Mi-young;Namgung, Hyeong Kyu;Song, Ji Hyeon;Hwang, Sun-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.306-310
    • /
    • 2009
  • Packed-bed reactor for removing ammonia was tested at different loading rates. Nitrifiers for ammonia removing was encapsulated in gel media which consisted of polyethlene glycol, alginate and activated carbon. The removal efficiency was nearly 100% when ammonia loading was $12g/m^3/hr$, and the maximum elimination capacity (EC) achieved on this study was $18g/m^3/hr$. The initial microbial portion of nitrifiers in the media was about 82% and it was increased to more than 90% at the end of the operation. Short-term shock loading test was carried out to survey the stability of the media. The inlet loading rates were varied from 2 to $20g/m^3/hr$. The packed-bed reactor overcame the shock loading i.e. removal efficiency recovered rapidly from about 80% to almost 100% within 6 hrs. The results of Live/Dead cell test showed that nitrifiers maintained there activity in the encapsulated media during the test and also against ammonia shock load.

Microbial ecology of the anaerobic and aerobic ammonia-oxidizers in full-scale wastewater treatment systems (하수처리장에서의 암모니아 전환 미생물군의 생태학적 연구)

  • Park, Hong-Keun;Kim, Young-Mo;Lee, Jae-Woo;Kim, Sung-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.399-408
    • /
    • 2012
  • The overall goal of this study was to characterize and quantify ammonia-oxidizing bacteria (AOB) in four different full-scale sequence batch reactor (SBR) wastewater treatment plants. Also, this study focused on assessing the occurrence of the alternative ammonia-oxidizing microbes such as anammox (anaerobic ammonia oxidation) bacteria (AMX) and ammonia-oxidizing archaea (AOA) in these systems. Based on total AOB numbers and the estimated cell density in the mixed liquor samples, AOB constituted 0.3 - 1.8% of the total bacterial population in the four WWTPs. Based on clone library, Nitrosomonas ureae-like AOB were dominant in plant A and B, while plant C and D had Nitrosomonas nitrosa-like AOB as major AOB group. The four different AMX primer sets targeting AMX 16S rRNA gene produced PCR amplicons distantly related to Chlamydia and Planctomycetales group bacteria. However, it was not clear these groups of bacteria perform anammox reaction in the SBR plants. Also, molecular evidence of AOA was found in one of the SBR plants, with a sequence located in the deep branch of the sediment creanarchaeota group.