• Title/Summary/Keyword: Ambient light

Search Result 362, Processing Time 0.153 seconds

Ambient Light Backscatter Communication for IoT Applications

  • Yun, Jisu;Jang, Byung-Jun
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.214-218
    • /
    • 2016
  • In this paper, we present an ambient light backscatter communication design that enables Internet of Things (IoT) devices to communicate through the backscattering ambient light emitted from lighting infrastructure or sunlight. The device can selectively modulate ambient light by switching a liquid crystal display (LCD) shutter located on its surface, so that a nearby smart device, which includes a photodiode or a camera, can demodulate this backscattered light information. To verify the practicality of the proposed concept, we design an IoT device equipped with a commercial LCD shutter and a microcontroller. Our device produces ambient light backscattered data at a speed of 100 bps, and these data are successfully decoded by a commercial photodiode module 10 cm away from the IoT device. We believe that our ambient light backscatter communication design is appropriate for implementation in various IoT applications.

Driving Method with Variable Integration Time for Ambient Light Sensing Circuit

  • Lim, Han-Sin;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1495-1498
    • /
    • 2008
  • We proposed driving method with variable integration time for ambient light sensing. One operation period of the proposed driving method consists of several sub-integration periods with variable integration time which can enlarge dynamic range of ambient light sensing circuit. Temperature dependent characteristic of p-intrinsic-metal (p-i-m) diode can be compensated using the proposed driving method.

  • PDF

Monolithic Ambient-Light Sensor System on a Display Panel for Low Power Mobile Display (저 전력 휴대용 디스플레이를 위한 패널 일체형 광 센서 시스템)

  • Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.48-55
    • /
    • 2016
  • Ambient-light sensor system, which changes the brightness of a display as ambient light change, was studied to reduce the power consumption of the mobile applications such as note PC, tablet PC and smart phone. The ambient-light sensor system should be integrated on a display panel to improve the complexity and cost of mobile applications, so the ambient-light sensor and readout circuit was integrated on a display panel using low-temperature poly-silicon thin film transistors (LTPS-TFT). We proposed the new compensation method to correct the panel-to-panel variation of the ambient-light sensors, without additional equipment. We designed and investigated the new readout circuit with the proposed compensation method and the analog-to-digital converter for the final digital output of ambient light. The readout circuit has very simple structure and control timing to be integrated with LTPS-TFT, and the input luminance ranges from 10 to 10,000 lux. The readout rate is 100 Hz, and maximum differential non-uniformity with 20 levels of the final output below 0.5 LSB.

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

Effect of light intensity on the ozone formation and the aerosol number concentration of ambient air in Seoul (광도가 서울 대기의 오존 생성 및 에어로졸 수 농도에 미치는 영향)

  • Bae, Gwi-Nam;Park, Ju-Yeon;Kim, Min Cheol;Lee, Seung-Bok;Moon, Kil-Choo;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.4 no.1
    • /
    • pp.9-20
    • /
    • 2008
  • The effect of light intensity on the ozone formation and the aerosol number concentration during the photochemical reactions of ambient air was investigated in an indoor smog chamber. The smog chamber consists of a housing, 64 blacklights, and a $2.5-m^3$ reaction bag made of Teflon film. The bag was filled with the unfiltered ambient air in Seoul from January 10 to March 18, 2002. In this work, the photolysis rate of $NO_2$, $k_1$ was used as an index of light intensity. Three levels of light intensity were controlled by changing the number of blacklights turned on among 64 blacklights: $0.29min^{-1}$ (50%), $0.44min^{-1}$ (75%), $0.57min^{-1}$ (100%). The ozone concentration increased rapidly within 10 minutes after irradiation irrespective of light intensity, thereafter it increased linearly during the irradiation. The ozone production rate seems to be dependent on both the light intensity and the quality of ambient air introduced into the reaction bag. The change in aerosol number concentration also depended on both the light intensity and the ambient air quality, especially aerosol size distribution. Based on the initial ambient aerosol size distributions, the photochemical potential for aerosol formation and growth is classified into two cases. One is the case showing aerosol formation and growth processes, and the other is the case showing no apparent change in particle size distribution.

  • PDF

A Study on Image Evaluation consequent on Lighting Environment in time of reading in Learning Space (학습공간에서의 독서 행위 시 조명환경에 따른 이미지평가 연구)

  • Lee, Jin-Sook;Park, Ji-Young;Seo, Eun-Ji
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.1-9
    • /
    • 2015
  • The aim of this study is to deduce color temperature and illuminance by conducting the preference & affective evaluation consequent on illuminance change of ambient light in case of the lighting method of ambient light mixed with task light in time of reading which is visual work action among the action in learning space. As a result of the prior survey on preferred lighting method in time of the act of reading targeting 20 experts before doing evaluation, the method of lighting mixed with ambient light and task light was found to be the highest. Such a result is analyzed to be attributable to the fact that the less the difference in illuminance of nearby space and work surface because of the mixed method of lighting, the less the glare, which makes a reader feels easy and concentrate on reading. On the basis of descriptive statistics of evaluation results and impact analysis by category, this study recommends the application of combinations of ambient light illuminance ranging from 40lx to 100lx with color temperature of 5500~6000K in case of the method of lighting mixed with general light and task light.

2.2 “ QVGA LTPS LCD Panel integrated with Ambient light Sensor

  • Weng, Chien-Sen;Chao, Chih-Wei;Tseng, Hung Wei;Peng, Chia-Tien;Lin, Kun-Chih;Gan, Feng-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1319-1322
    • /
    • 2007
  • Planar PIN photodiode is compatible with LTPS process, and its fabrication requires no additional manufacturing process. In this study we design the optimum dimension of PIN diodes with two nitride layers to improve the efficiency of PIN diodes. The PIN photo sensor shows very good sensitivity to ambient light illuminance.

  • PDF

A Study on the Effects of Ambient Light on the Reflective PPG Measurement Device using Infrared (적외선을 사용한 반사형 PPG 측정 장치에서의 주변광의 영향에 대한 연구)

  • Namsub Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.406-412
    • /
    • 2023
  • In this paper, we studied the effect of noise caused by ambient light on a reflective PPG measurement device using infrared light. Noise caused by ambient light was examined by dividing it into general situations and special situations. In the general situation, noise due to changes in time and ambient light sources was randomly observed, and in the special situation, a halogen lamp was used to observe the effect of noise variations. In the experiment, PPG signals were measured and data acquired in real-time depending on each situation, and the measured data was analyzed in the time domain and frequency domain. First, through a general situation experiments, it was visually observed that noise increases with the brightness of ambient light, and through frequency analysis, it was observed that the noise sources were white noise, power line noise, and internal noise of the circuit. Futhermore, using a halogen lamp, we experimented with the change in noise depending on the change in distance from the ambient light and calculated the SNR. As a result of the experiment, an SNR of 3.2 dB was shown at a distance of 50 cm with an irradiance of 278.3 W/m2. It was observed that normal measurement was difficult at SNRs below that, and an irradiance of 27.7 W/m2 was obtained. It showed a value of 18.2 dB at a distance of 2 m, and it was observed that normal PPG measurement was possible through a filter at values above that.

A Comparative Evaluation on Visual Performance of CRT and TFT-LCD as Desktop Computer Displays (데스크탑용 CRT와 TFT-LCD의 시각 작업수행도 비교·평가)

  • Kim, Sang-Ho;Choi, Kyung-Lim
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.95-112
    • /
    • 2002
  • Two experiments were carried out to compare the suitability in visual tasks between cathode-ray tube (CRT) and thin film transistor-liquid crystal display (TFT-LCD). In the first experiment, the subjects were requested to detect pre-assigned target words or icons among distracters presented under time-invariant (static) image mode. The subjects' visual performance and fatigue were assessed while carrying out search tasks with dim and bright ambient light conditions. Significant interaction effects were found among displays, task types, and ambient light conditions. Due to visual fatigue, the subjects' accommodative power decreased in the end of task and the degradation was more significant for the CRT users and under bright ambient light. IN the second experiment, the subjects performed information processing task with time-varying road signs at a driving simulator to assess interaction effects between display types and changing speed of dynamic image. The perception time using TFT-TCD was shorter under slow image change while that of CRT was shorter rapid image change. Findings from this study suggest that, to improve visual task performance, users should carefully select their visual display type depending on the task to be performed.

Corresponding Color Reproduction on CRT between Illuminated Environment viewing Conditions (관찰환경에 따른 소프트카피의 대응적 색재현)

  • 곽한봉;안성아;서봉우;이영호;안석출
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.241-244
    • /
    • 2001
  • A various color device became generalization. Therefore, request about expression of correct color is increased. Device independent color reproduction system acquires and reproduce color of object regardless characteristic of Input/Output device. Human visual system is partially adapted to the CRT monitor's white point and the ambient light. The visual experiments were performed on the effect of the ambient lighting under mixed chromatic adaptation. In this paper, It was found that human visual system is 40% to 60% adapted to CRT monitor's white point light and the rest to ambient light.

  • PDF