• Title/Summary/Keyword: Amalgam

Search Result 301, Processing Time 0.027 seconds

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF THE AMALGAM AND GALLIUM ALLOY (아말감과 갈륨알로이의 미세 변연 누출에 관한 비교 연구)

  • Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.323-334
    • /
    • 1998
  • The purpose of this study was to compare the microleakage of the amalgam and the gallium alloy when several lining materials were applied. The ANA 2000, high copper lathecut type amalgam(AM group) and Gallium Alloy GF II (GF group) were used. The fifty extracted sound molars were randomly assigned to AM group and GF group, and the buccal and lingual class V cavities with a size $3{\times}2{\times}2mm$ were prepared. The prepared cavities were randomly assigned to group 1 : no liner used control, group 2 : Copalite, group 3 : Panavia 21, group 4 : All-bond 2, and group 5 : Superbond C&B. After liner placement and amalgam filling, the specimens were stored in $37^{\circ}C$ normal saline for 24 hours and then thermocycled from $5^{\circ}C$ to $55^{\circ}C$ thousand times. The specimens were stored in the 1% methylene blue solution for 24 hours and sectioned and examined by stereomicroscope. The results obtained from this study can be summarized as follows : 1. In the GF group, microleakage values of group 2, 3, 4, 5 were significantly lower than that of group 1 (p<0.05). 2. In the AM group, microleakage values of group 3 and 4 were significantly lower than that of group 1 (p<0.05), but microleakage values of group 2 and 5 did not differ from that of group 1 (p>0.05). 3. The GF group was similar(group, 1 3, 4) or superior(group 2, 5) to the AM group in the aspect of the microleakage.

  • PDF

Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth

  • Francio, Luciano Andrei;Silva, Fernanda Evangelista;Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Jansen, Wellington Correa;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.87-96
    • /
    • 2018
  • Purpose: The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). Materials and Methods: Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. Results: For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P<.05). CBCT images exhibited good results for resin restorations(P>.05), but showed no discriminatory ability for amalgam restorations(P<.05). Conclusion: Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.

COMPARISON OF THE PHYSICAL PROPERTIES BETWEEN GALLIUM ALLOY AND HIGH COPPER AMALGAM ALLOYS (갈륨합금과 고동 아말감 합금의 물리적 성질 비교)

  • Kim, Hyeon-Cheol;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.278-287
    • /
    • 1998
  • The purpose of this study was to compare the physical properties between high copper amalgam and gallium restorative material. In this study, the specimens for the 4 experimatal groups (Valiant, Valiant PhD, Gallium Alloy GF II. Gallium Alloy GF II triturated with some addition of alcohol) were prepared in the manner of which stated in ADA specification No.1 for amalgam alloy. And then, measured and compared the value of compressive strength. creep, and dimensional change during hardening of each sample. The results were as follows: 1. In the compressive strength, the Valiant-lathe cut type high copper amalgam-had the highest value of strength(p<0.05), and the Valiant PhD-admixed type high copper amalgam-showed the higher value of strength than the Gallium Alloy GF II(p<0.05) but had no significant difference with Gallium Alloy GF II triturated with some addition of alcohol(p>0.05). 2. In the creep. the Valiant PhD showed the highest value of creep (p<0.05), but there was no significant difference between Gallium Alloy GF II and Valiant(p>0.05). 3. In the dimensional change during hardening, no two groups were significantly different at the 0.050 level. 4. There was no significant difference between Gallium Alloy GF II and the same material which was triturated with some addition of alcohol(p>0.05).

  • PDF

THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT (Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향)

  • Ha Jum-Im;Cho Hye-Won;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

Study for the Film Coating Techniqur of Gilt Bronze Artifacts from Mir ksa Temple (미륵사지 출토 고대 금동유물의도금기법에 관한 연구)

  • Lim, Sun-Ki;Kang, Dai-Ill;Kim, Sun-Dug;Park, Dong-Kyu;Kang, Sung-Goon
    • 보존과학연구
    • /
    • s.14
    • /
    • pp.45-76
    • /
    • 1993
  • Au-Cu alloyed coating layer were found by Hg-amalgam process and it seemed to be used Cu-amalgam process similar to Au-amalgam. Coated layer is dense and unique, Thickness of layer was 1.5 to $18.0\mum$ which had 95.3 to 99.8% purity of gold Matrix metal mostly cosists of forged copper alloy which had high purity and ferrite ($\alpha$) strusture. It showed excellent refining technical level at that time. Aowever, the nail, ferrous matrix used for strength needed, composed of silver foil packed and gold layer for adherence between ferrous matrix and gold layer

  • PDF

MERCURY LEAKAGE TO SALIVA AFTER AMALGAM FILLING (아말감 충전후(充塡後) 수은(水銀)의 타액내(唾液內) 누출(漏出)에 관(關)한 연구(硏究))

  • Kim, Soo-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.8-10
    • /
    • 1975
  • This study is to determine or detect deposition of mercury particles emitted from dental amalgam fillings. Amalgam fillings were carried out routinely on the dogs' teeth. (CIV cavities) Mercury which contains about 200${\mu}Ci$ of $^{197}Hg$ was employed on this purpose in each cavity. Radioactivity was measured by means of well type scintillation counter from saliva and mucous membrane of surrounding tissue. The C. P. M. value from the saliva was highest, mucous membrane was moderate and least on blood and fecs, as shown table on I. II. III. IV. 1. C.P. Mvalue from Saliva reveals 114 to 135 (lowest and highest) throughout the measuring period until 41 hours. 2. From blood samples no significant value was found. 3. CPM value from feces at2nd day and 4th day was about 90. 4. The highest and lowest CPMvalue from marginal gingiva was 465 and 209 respectively. Palatine showed 281 and 189, esophagus 179 and 165, and pulp from experiment tooth 190 and 104 respectively.

  • PDF

Attachment of Human Gingival Fibroblast to Various Subgingival Restorations;A Comparative Study in Vitro (다양한 치은 연하 수복물에 대한 치은 섬유아 세포 부착 연구)

  • Lee, Eun-Suk;Song, In-Taeck;Lim, Jeong-Su;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.621-636
    • /
    • 1999
  • When mucoperiosteal flaps are positioned and sutured to desirable position, the wound contains several interface between tissues which differ fundamentally in composition & biological reaction. Thus the C-T surface of the flap will, on one hand, oppose another vascularized surface, and on the other, the avascular dental material for example, when root resoptions, fractured root, endodontic perforation, deep root carious lesions were filled with amalgam, glass ionomer, resin etc. Recently, a number of case report described the successful treatment of a subgingival root lesion with restorative material & free gingival graft, open flap surgery, but more objective research was needed . Most of study on restorative materials were concerned for cytotoxicity not for actual healing event on that materials and its influencing factors such as biocompatibility, surface wettability, surface topography . The aim of this in vitro study was to evaluate the effect of amalgam, resin modified glass ionomer, composite resin per se, and their surface roughness on the growth of human gingival fibroblast. The cells were obtained and placed on culture flask and incubated for 3 days with the prepared test materials. Then count the attached cell number with hemocytometer,(n=12) and 2 samples were examined with SEM about attachment cell morphology . Another 4 samples were evaluated on their surface roughness with Talysurf and average surface roughness value(Ra) were obtained. Statistical difference in attached cell number, roughness value were analyzed using ANOVA. The number of attached cell was as follows, for root dentin specimen 16.7${\pm}$4.41, resin modified glass ionomer 14.0${\pm}$4.15, resin 8.13${\pm}$3.63, amalgam 0.72${\pm}$3.33(${\times}10^3$). Between root dentin and resin-modified glass ionomer, no significant difference was observed, but resin, amalgam showed a significant less cell numbers than for root dentin, resin modified glass ionomer cement. SEM examination expressed many cell surface attachment apparatus in root dentin and resin modified glass ionomer specimens. For resin specimen, cell attachment was observed but exposed less appratus. The average surface roughness value are following results. Dentin specimen 0.6972${\pm}$ 0.104, resin modified glass ionomer 0.0822${\pm}$0.009, resin 0.0875${\pm}$0.005, amalgam 4.2145${\pm}$0.985(${\mu}m$). Between root dentin, resin-modified glass ionomer, and resin, no significant difference was observed, but amalgam showed a significant more rough surface than other groups. When evlauated the interrelationship between cell attachment and surface roughness, therefore, there was weak reverse correlation.(pearson correlation : - 0.593) These results suggest that resin modified glass ionomer have the favorable healing potential when used for subgingival restoration. And for relationship between cell attachment and surface characteristics, further investigations were needed.

  • PDF

Restoration of Gold Gilding Using Plum Acid for Geumdong-samjonpanbul Excavated from Walji, Gyeongju (매실산을 이용한 월지 출토 금동삼존판불의 금도금법 복원)

  • Yun, Yong Hyun;Cho, Nam Chul;Yoon, Dae-Sik;Lee, Tae Sub;Bae, Chaerin
    • Journal of Conservation Science
    • /
    • v.33 no.2
    • /
    • pp.107-120
    • /
    • 2017
  • This research involves a gilding experiment using plum acid that has previously been reported to restore Geumdongsamjonpanbul excavated from Wolji, Gyeongju. Chromaticity analysis revealed that the yellowness of the samples was high, and the samples treated with acid for more than 10 minutes showed high brightness. SEM studies revealed that the sample subjected to amalgam application and immediate heating was rarely gilded with gold. When the amalgam application time was longer than 36 h, the gold layer observed was uneven. Therefore, the optimum amalgam application time was 12-24 h. EDS analysis showed that mercury content was ~5 wt.% for samples with an acid treatment time of 20 min, lower than that in other samples. Gold gilding was successful for the sample with amalgam application time of 24 h and acid treatment time of 20 min. This sample showed the high-resolution XPS peak corresponding to Au and retains a little Hg compared with the other samples. In other words, experimental and analytical results using plum acid showed that gilding was successful when acid treatment time was 20 min and amalgam application time was 24 h. Based on these results, Geumdongsamjonpanbul excavated from Wolji, Gyeongju can be restored.

AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS (II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구)

  • Lee, Kye-Hyuck;Hur, Seung-Myun;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).