• Title/Summary/Keyword: AmBe

Search Result 1,659, Processing Time 0.034 seconds

Pre-distorter Method Using LUT with 2ι Partition Interpolation in the OFDM System (OFDM 시스템에서 2ι 분할 보간을 LUT에 결합한 전치왜곡기에 관한 연구)

  • 권오주;이호근;하영호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7A
    • /
    • pp.668-675
    • /
    • 2002
  • This paper proposes pre-distorter combined LUT with 2ιpartition interpolation method to reduce nonlinear distortion which was caused by high PAPR and to update LUT quickly. Pre-distorted gain and phase can be found by using LUT which consisted of AM/AM and AM/PM value, and OFDM signal amplitude. The proposed 2ιpartition interpolation can accurately find predistorted gain and phase using bit shift and add component instead of increasing size of LUT which requires increasing the amount of computation. The performance of the proposed method was measured by the difference between HPA input and output characteristics by the LUT size, constellation, SER performance by the HPA, and LUT update error by the HPA characteristic changes. As a result, it is shown that when the size of the LUT is 32 and 64 for 16-QAM and 64-QAM, nonlinear distortion nearly didn't occurred.

Implementation of the Vehicle Antenna for the AM/FM/TDMB/GPS Receiver (AM/FM/TDMB/GPS 수신용 전장 안테나 제작)

  • Kim, Joo-Man;Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.105-113
    • /
    • 2009
  • In this paper, a vehicle antenna for AM, FM, TDMB, GPS systems was designed and implemented. AM antenna loaded into small space of shark shape was designed by ferrite turn style antenna. For the FM and TDMB antenna, folded monopole antenna which helical is folded was applied. GPS antenna for achieving characteristics both bandwidth and gain improvement was designed microstrip patch that has air substrate and fractal structure. Receiving signal strengths by the measurement were presented for the AM, FM and TDMB antenna. AM signal strength was -65.7dBm, this strength is almost as same conventional pole antenna as -63.4dBm. It can be replaced conventional pole or glass antenna by the studied antenna. Signal strengths for FM and TDMB were -55.66 and -43.50dBm at center frequency, they are 5~10dB higher than conventional antenna. Measurements of bandwidth and gain for the GPS antenna showed 135 MHz under VSWR 2 : 1 and 4.31dBi, gains over GPS band were 3~5dB higher than ceramic patch antenna.

  • PDF

An Analog Predistortion Linearizer using Series Feedback Structure (직렬 궤환을 이용한 아날로그 전치왜곡 선형화기)

  • Kim, Ell-Kou;Jeon, Ki-Kyung;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.3
    • /
    • pp.256-262
    • /
    • 2006
  • This paper proposes a new predistortion linearizer to compensate for AM/AM and AM/PM in the nonlinear characteristics of amplifier. This consists of common-emitter amplifier and schottky diode that is connected between emitter and ground. When effective resistance of the schottky diode with bias condition varies, common-emitter amplifier with series feedback has a increase of amplitude and expansion of phase. This makes a amplifier nonlinear characteristics are to be improved. The proposed linearizer and amplifier has been manufactured and tested to operate in cellular base station frequency (869~894MHz). The test results show that third order intermodulation distortion (IMD3) cab be removed by more than 10.4dB in case of CW 2-tone signals ${\Delta}f$=1MHz, and the adjacent channel power ratio (ACPR) also can be improved by more than 9.6dB for CDMA IS-95 1FA signals.

  • PDF

Review on additive manufacturing of dental materials (치과용 재료의 적층가공에 대한 문헌고찰)

  • Won, Sun;Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Additive manufacturing (AM) for dental materials can produce more complex forms than conventional manufacturing methods. Compared to milling processing, AM consumes less equipment and materials, making sustainability an advantage. AM can be categorized into 7 types. Polymers made by vat polymerization are the most suitable material for AM due to superior mechanical properties and internal fit compared to conventional self-polymerizing methods. However, polymers are mainly used as provisional restoration due to their relatively low mechanical strength. Metal AM uses powder bed fusion methods and has higher fracture toughness and density than castings, but has higher residual stress, which requires research on post-processing methods to remove them. AM for ceramic use vat polymerization of materials mixed with ceramic powder and resin polymer. The ceramic materials for AM needs complex post-processing such as debinding of polymer and sintering. The low mechanical strength and volumetric accuracy of the products made by AM must be improved to be commercialized. AM requires more research to find the most suitable fabrication process conditions, as the mechanical properties and surface of any material will vary depending on the processing condition.

Arbitrary Sampling Method for Nonlinearity Identification of Frequency Multipliers

  • Park, Young-Cheol;Yoon, Hoi-Jin
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 2008
  • It is presented that sampling rates for behavioral modeling of quasi-memory less nonlinear devices can be far less than the Nyquist rate of the input signal. Although it has been believed that the sampling rate of nonlinear device modeling should be at least the Nyquist rate of the output signal, this paper suggests that far less than the Nyquist rate of the input signal can be applied to the modeling of quasi-memoryless nonlinear devices, such as frequency multipliers. To verify, a QPSK signal at 820 MHz were applied to a frequency tripler, whereby the device can be utilized as an up-converting mixer into 2.46 GHz with the aid of digital predistortion. AM-AM, AM-PM and PM-PM can be successfully measured regardless of sampling rates.

Average and Effective Energies, and Fluence-Dose Equivalent Conversion Factors for $^{239}Pu-Be,\;^{241}Am-Li\;and\;^{241}Am-F$ Neutron Sources

  • Ro, Seung-Gy;Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.155-160
    • /
    • 1971
  • Average and effective energies for 239Pu-Be, 241Am-Li and 241Am-F neutron sources have been calculated from a number of published data for the neutron spectra and for the dose equivalent as a function of neutron energies by a numerical method. Also a calculation of the dose equivalent conversion factors, i. e., the first collision dose equivalent and the surface (or multicollision) dose equivalent that equals the product of surface-absorbed dose and a corresponding quality factor, per unit fluence of neutrons from these sources has been carried out in the same way as before. The results are as follows : 1. for average energies 4.07$\pm$0.33, 0.42 and 1.41 MeV; 2. for effective energies based on the concept of the first collision process in the human body 4.45$\pm$0.344, 0.51 and 1.47 MeV; 3. for effective energies based on the concept of the multi-collision process in the human body 4.50$\pm$0.36, 0.50 and 1.45 MeV; 4. for fluence-first collision dose equivalent conversion factors (2.74$\pm$0.07)10$^{-8}$ , 1.58$\times$ 10$^{-8}$ and 2.34$\times$10$^{-8}$ rems/(n/$\textrm{cm}^2$); and 5. for fluence-surface dose equivalent conversion factors (3.55$\pm$0.09)10$^{-8}$ , 2.19$\times$10$^{-8}$ and 2.82$\times$10$^{-8}$ rems/(n/$\textrm{cm}^2$) : respectively.

  • PDF

A Study on the Usefulness of Subjective Lumbar Instability Factor for Respiratory Pattern Change and Abdominal Mobility in Peoples with CLBP (만성허리통증자의 호흡 패턴과 배부 운동성 변화에 대한 주관적 허리부위 불안정성 요소의 유용성에 관한 연구)

  • Ki, Chul;Lee, Kwan-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.206-214
    • /
    • 2020
  • This study examined the correlation between the respiratory pattern change (RPC) and abdominal mobility (AM) according to the positive result of the subjective lumbar instability factor (SLIF) in people with chronic low back pain (CLBP). Thirty-six adults with CLBP participated in this study. Twenty-eight items of the SLIFs were examined, and the subjects were divided into three groups according to the positive response numbers (PRN). After the change lists were scored, three RPC scores [costo-diaphragmatic RPC (CDRPC), breath hold change (BHC), and total RPC (TRPC)] were obtained. The abdominal mobility (AM) was measured between the maximal inspiration and exhalation at the xiphoid (AM1) and the 10th rib (AM2) level of the trunk. The results showed that the RPC score and AM were compared according to the positive response number of SLIF, and the relationship between them was analyzed. A positive correlation was observed between the SLIF positive response number and CDRPC score, BHC score, and total RPC score, and a negative correlation was observed between the SLIFs positive response number and AM1 and AM2. Based on the results of this study, the combination of SLIF positive responses can be a predictor of non-physiological respiratory pattern changes in people with CLBP. Clinically, this prediction is expected to help save time for screening and improve the efficiency of therapy.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

The Effect of Cosmetic on Anti-Wrinkle of Acer mono Sap (우산고로쇠의 향장효과)

  • Sohn, Sang Hyun;Lee, Sang Won;Shin, Yu Su;Kim, Hyung Don;Yang, Seung Ok;Kim, Seung Yu;Kim, Young Ock
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.4
    • /
    • pp.262-267
    • /
    • 2013
  • The purpose of this study was to research for anti-oxidation and anti-wrinkle effects of Acar mono Sap (AM). To cosmetic effect of AM, safety effect (MTT assay), anti-wrinkle effect (elastase, MMP-1 inhibition assay) and anti-oxidant effect (DPPH assay) were measured. When water extract of AM was used for cell viability, it was over 100% at 6% (6 ml/100 ml in phosphate buffer) concentration. AM showed 45.7% elastase inhibition and 23.7% MMP-1 inhibition at 50% (50 ml/100 ml in phosphate buffer) concentration so that it had good anti-wrinkle characteristic. And AM showed 68.9% antioxidation capacity at 50% concentration by using a DPPH assay. Consequently, AM can be used as natural materials or additives for human skin owing to their beneficial biologic functions, including the anti-wrinkle effect, for cosmetic compositions.

Use of americium as a burnable absorber for VVER-1200 reactor

  • Shelley, Afroza;Ovi, Mahmud Hasan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2454-2463
    • /
    • 2021
  • The objective of this research is to the use of americium (AmO2) as a burnable absorber effectively instead of conventional gadolinium (Gd2O3) for VVER-1200 reactor by analyzing its impacts on reactivity, power peaking factor (PPF), safety factor, and quality of the spent fuel. The assembly is burned to 60 GWd/t by using SRAC-2006 code and JENDL-4.0 data library for finding the optimum amount and effective way of using AmO2 as a burnable absorber. From these studies, it is found that AmO2 can decrease the excess reactivity like Gd2O3 without changing the criticality life span and enrichment of 235U. A homogeneous mixture of the 0.20% AmO2+ 4.95% enriched UO2 fuel rod (model MF-4) decreases the PPF than the reference assembly. The use of AmO2+UO2 in the integral burnable absorber (IBA) rod or the outer layer could also decrease the PPF up to 10 GWd/t but increases rapidly after 30 GWd/t, which could be a safety threat. The fuel temperature coefficient and void coefficient of the model MF-4 are the same as the reference assembly. In addition, 22% of initially loaded Am are burning effectively and contributing to the power production.