Heat Characteristics of Electric Fittings for Power Transmission Line (송배전 접속 금구류의 도전 열특성에 관한 연구)

  • 이창식;진양덕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.697-702
    • /
    • 1989
  • This study deals with the heat cycle characteristics of sleeve connector of aluminum stranded conductors steel reinforced(ACSR). In order to investigate the effect of heat cycle on the sleeve connector of stranded conductor, experimental study has been performed for both the temperature rising and electrical resistance of sleeve connector. Also, the effect of changes in surrounding temperature on the allowable current of sleeve connector was studied in order to investigate the influence on the connector size of conductor. Under the given test conditions of heat cycle, the temperature rising s decreased with the increase of sleeve size of conductor. The deviation of resistance of sleeve connector in conductor decreased with the increase in the size of sleeve connector.

Evaluation of Effect for Connector System in Reinforced Earth Retaining Wall (보강토 옹벽에서 연결시스템의 영향성 평가)

  • Lee, Jun-Dae;Heo, Yol;Ahn, Kwang-Kuk;Lee, Yong-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.85-94
    • /
    • 2006
  • In this study, in order to evaluate the effect of two types of connector systems in reinforced retaining wall, the centrifugal tests for the conventional connector and new settlement connector system were performed. In the centrifugal tests, the aluminum plate for the face was used and the aluminum foil was used as a reinforcement. The granite soil was adopted as a fill. As a result, The settlement reinforced retaining wall reached to the failure at 80g-level. In contrast, the conventional reinforced retaining wall was collapsed at 69g-level. It means that the settlement reinforced retaining wall has the stronger stability than the conventional reinforced retaining wall. In addition, it was shown that the settlement connector system is more effective to release the stress concentration occurred at the face of reinforced retaining wall than the conventional connector system.

Development of Automatic Resistance Measuring System for Aluminum Connector (금구류 히트사이클 시험용 자동 저항측정 시스템 개발)

  • Park, Sung-Kyun;Son, Hwa-Young;Ryu, Jae-Nam;Kim, Kyung-Hwan;Park, Byung-Rak;Park, Choong-Yeol;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.161-163
    • /
    • 1997
  • Heatcycle testing for aluminum connector is very important. But because of connecting or disconnecting the test circuit, measuring resistance is difficult. Also the previous measuring resistance instrument is analog type. So measuring method is difficult. And four measuring points for one test circuit cause difficulty in automation. In this paper we developed the automatic system for measuring resistance. Automation will allow more information to be gathered, which will lead to the connector aging process being better understood and controlled.

  • PDF

Development of Connector Sealing Method for Maintaining of Vacuum in the Momentum Wheel (모멘텀 휠의 내부 진공 유지를 위한 커넥터 밀봉방법 개발)

  • Cheon, Dong-Ik;Gong, Sung-Chul;Oh, Hwa-Suk;Lee, Seung-Wu
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.25-30
    • /
    • 2008
  • In general, we utilize momentum wheel to control spacecraft. It needs vacuum test to analyze the effect of space environments. The conventional vacuum connector which is composed of steel has problems for test with built in momentum wheel because of weight, thermal expansion, etc. We suggest possibility to manufacture the vacuum connector using aluminum mount, epoxy and industrial D-Sub considering cost, weight. We verify the performance through vacuum test.

  • PDF

Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재 개발 및 최적 보강량 산정을 위한 해석적 연구)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.136-145
    • /
    • 2013
  • Social interest in the seismic retrofit of the structure is growing massive earthquake that occurred recently. The brittle fracture of Non-seismically designed Columns lead to full collapse of the building. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly in recent years, fiber-reinforced method utilizing the advantages of the composite material are preferred. However, the reinforcement methods such as this, there is a drawback to induce physical damage to structures, and time consuming work space is large. IIn this study, FRP seismic reinforcement was developed using the Aluminum connector and the composite material (Glass Fiber Reinforced Polymer). Then, the optimum quantities of FRP seismic reinforcement was determined using a nonlinear finite element analysis program. Finally, the quantity decision process through the design and analysis of FRP reinforcement was suggested.

An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors (전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석)

  • Kang, Dong Howa;Kang, Dong Hwa;Shin, Dong Hyeon;Kim, Hyung Joon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

Effect on the Stress and Displacement of Aluminum Profiles Fastening Method (알루미늄 프로파일의 체결방법이 응력과 변위에 미치는 영향)

  • Hur, Jang-Wook;Shin, Baek-Cheon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.99-104
    • /
    • 2015
  • This study analyzed the effects on displacement and stress as a result of improving the profile fastening method targeting rectangular-shaped and cube-shaped specimens. For the rectangular-shaped specimens, the improved fastening method reduced maximum displacement to 41.7% and maximum stress to 18.3% compared to the existing fastening method. For the cube-shaped specimens, maximum displacement and maximum stress results were found to be similar to those of the rectangular-shaped specimens. Thus, as a result of comparing the stress and displacement of the existing and improved fastening methods, it was found that the improved fastening method is superior to the existing fastening method in terms of load support.

A Study on Realization of Wireless Umbilical Device for Missile Systems (유도무기체계의 무선배꼽장치 구현연구)

  • Eun, Heehyun;Jung, Sukjong;Jung, Jaewon;Ro, Donggyu;Kang, Cheewoo;Park, Youngsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.813-821
    • /
    • 2017
  • This paper presents the study result on a realization of wireless umbilical device for missile systems. In general, a missile system is connected to a fire control equipment via an umbilical connector to get the electrical power for its internal equipment and communicate with each other. And these connectors inherently have many problems of mis-contact between pin and socket, and mis-separation during missile firing, etc. A wireless umbilical device using LC resonance is devised to solve these problems of the current technology. For hundreds of watts power transmission under the missile system environment of restricted space, we designed and made a prototype of wireless umbilical device. And we tested this wireless umbilical device with an aluminum cylinder having cutout windows which simulate missiles. We realized that the wireless technology can be used as a substitute for the conventional umbilical connectors, and EMI and environment tests should be followed further.

An Experimental Study on Seismic Performance Evaluation of Retrofitted Column of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재로 보강된 기둥의 내진성능평가 실험)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.21-30
    • /
    • 2013
  • As increasing number of large-size earthquake, the social interest of seismic retrofitting of RC structure is growing. Especially, the RC columns that are not reflected seismic design can not resist lateral loads by the earthquake. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. Thus, the emergency columns reinforcement method is needed. That have a fast construction time, do not cause damage to the column. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly, but in recent years, carbon fiber sheet taking advantage of FRP (Fiber Reinforced Polymer) is widely used. In this study, retrofitting effect of seismic performance of FRP seismic reinforcement, which is possible to emergency construction, was examined. Reinforced concrete specimens were constructed to experimental study. The seismic performence of specimes retrifitted with FRP seismic reinforcement were evaluated. As a result, the seismic performance of specimen reinforced with FRP seismic reinforcement has been improved.