• 제목/요약/키워드: Aluminum Tube

검색결과 243건 처리시간 0.025초

열전냉각소자와 열전발전소자의 발전특성 (Characteristics of electric power for thermoelectric cooling & generating module)

  • 우병철;이희웅;이동윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.448-451
    • /
    • 2000
  • The purpose of this study is to manufacture and test a thermoelectric generator which converts unused energy from close-at-hand sources, such as garbage incineration heat and industrial exhaust, to electricity. A manufacturing process and the properties of a thermoelectric generator are discussed before simulating the thermal stress and thermal properties of a thermoelectric module located between an aluminum tube and alumina plate. We can design the thermoelectric modules having the good properties of thermoelectric generation. Resistivity of thermoelectric module for thermoelectric generation consisting of 62 cells was 0.15-0.4$\Omega$ Developed thermoelectric modules can be expected th have better properties than thermoelectric cooling modules above $70^{\circ}C$ in temperature difference between hot and cold ends.

  • PDF

태양열 집열판의 레이저용접을 위한 공정변수 평가 (Evaluation of Process Parameter to Laser Welding of Solar Panel)

  • 김용;박기영;김부환
    • 한국레이저가공학회지
    • /
    • 제14권4호
    • /
    • pp.9-13
    • /
    • 2011
  • The solar panel that consists of copper plate and copper tube was successfully welded by ultrasonic seam welding. However it was not only expensive the copper material but also ultrasonic welding has many problem such as high error rate, difficulty of dissimilar material welding, noise, etc. At this study, the laser welding of solar panel with aluminum plate instead of copper. The welding were carried out with the pulsed Nd:YAG laser and the weld bead geometry was measured with the variation of pulse energy. Consequently, there was no difference between the ultrasonic and the laser welding on the performance of heat transfer capacities. Also the formation of intermetalic compound such as CuAl2 was increased with the pulse energy.

  • PDF

빙점이하에서 과일쥬스의 밀도측정방법 및 예측모델 (Density Measurement Technique and Prediction Model of Fruit Juices under Freezing Point)

  • 배동호;최용희
    • Current Research on Agriculture and Life Sciences
    • /
    • 제6권
    • /
    • pp.163-169
    • /
    • 1988
  • 본 연구는 식품의 동결시 동결기구의 설계 및 동결에너지의 효율적인 운용등을 위하여 동결상태에서 과일쥬스의 농도 및 온도변화에 따른 밀도변화를 예측하기 위하여 수행되었다. 10, 15, 20, 25, 30, 35, 40%농도의 Orange Juice, Apple Juice, Grape Juice 및 Sucrose Solation을 시료로 하여 온도강하에 의해 동결팽창되는 부위를 제거하므로써 거기에 따른 무게변화를 $-5^{\circ}C$에서 $-40^{\circ}C$까지의 온도범위에서 $5^{\circ}C$ 간격으로 각각 측정하여 밀도를 산출하였다. 그리고, Heldman의 식을 이용하여, 위의 농도와 온도범위에서 각 과일쥬스와 Sucrose Solution의 Unfrozen water fraction을 계산하였다. 실험을 통해 측정된 밀도데이타와 Unfrozen water fraction 데이타를 최적화 컴퓨터 프로그램을 이용하여 10%에서 40%까지의 농도범위와 $-5^{\circ}C$에서 $-40^{\circ}C$까지의 온도범위에서 Orange Juice, Apple Juice, Grape Juice 및 Sucrose Solution의 밀도를 예측할 수 있는 모델을 수립하였다.

  • PDF

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

저속 영역에서 루버휜이 장착된 평판관형 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구 (Air-side Performance of Louver-Finned Flat Aluminum Heat Exchangers at a Low Velocity Region)

  • 조진표;오왕규;김내현;윤백
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1681-1691
    • /
    • 2002
  • The heat transfer and pressure drop characteristics of heat exchangers with louver fins were experimentally investigated. The samples had small fin pitches (1.0 mm to 1.4 mm), and experiments were conducted up to a very low frontal air velocity (as low as 0.3 m/s). At a certain Reynolds number (critical Reynolds number), the flattening of the heat transfer coefficient curve was observed. The critical Reynolds number was insensitive to the louver angle, and decreased as the louver pitch to fin pitch ratio (L$_{p}$F$_{p}$) decreased. Existing correlations on the critical Reynolds number did not adequately predict the data. It is suggested that, for proper assessment of the heat transfer behavior, the louver pattern in addition to the flow characterization need to be considered. The heat transfer coefficient increased as the fin pitch decreased. At low Reynolds numbers, however, the trend was reversed. Possible explanation is provided considering the louver pattern between neighboring fins. Different from the heat transfer coefficient, the friction factor did not show the flattening characteristic. The reason may be attributed to the form drag by louvers, which offsets the decreased skin friction at a low Reynolds number. The friction factor increased as the fin pitch decreased and the louver angle increased. A new correlation predicted 92% of the heat transfer coefficient and 90% of the friction factor within $\pm$10%.10%.

A Inclined Slot-excited Circular Plasma Source with a Cusp Magnetic Field

  • You, H.J.;Kim, D.W.;Koo, M.;Jang, S.W.;Jung, Y.H.;Lee, B.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.435-435
    • /
    • 2010
  • A inclined slot-excited plasma source is newly designed and constructed for higher flux HNB(Hyperthermal Neutral Beam) generation. The present source is different from the vertical SLAN(SLot ANtenna) sources [1] in two aspects. One is that the slots are inclined, and the other is that the magnetic field is configured to a cusp type. These modifications are intended to make the source plasma operated in sub-milli-torr pressure regime and as thin as possible, both of which is to get higher HNB flux by decreasing the re-ionization rate of the reflected atoms from the neutralizer [2]. The plasma is generated in a quartz tube of internal diameter 170 mm enclosed in a aluminum application chamber of larger diameter 250 mm. The microwave power is fed to the plasma chamber by 8 inclined slots cut into the application chamber wall. The slots are coupled the chamber to a WR280 waveguide wound around it to form a ring resonator. In order to make two slots $\lambda_g/2$ apart in phase, the adjacent slots are rotated in opposite directions. The rotation angle of the slots are set to $60^{\circ}$ from the chamber axis. Between the quartz chamber and the aluminum cylindrical chamber 8 NdFeB magnets are equally spaced and fixed to form the cusp magnetic field confinement and ECR (Electron Cyclotron Resonance) field. In this presentation, the magnetic and electromagnetic simulations, and the measured plasma parameters are given for both the inclined and the vertical slot-excited plasma sources. We also discuss how the sources can be tailored to suit better-performing HNB sources.

  • PDF

유방촬영용장치 부가필터에 따른 선량변화 및 화질개선 (Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography)

  • 조우일;김영근;이길동
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.78-90
    • /
    • 2013
  • 최근 방사선 피폭에 대한 관심이 높아지고 있다. 유방촬영용장치의 방사선 피폭은 일반 X선 촬영에 비해 비교적 흡수선량이 높기 때문에 화질은 개선하되 불필요한 피폭을 줄여야 노력을 할 필요가 있다. 최근 국제방사선방어위원회(ICRP)나 우리나라의 한국의료영상품질관리원(KIAMI)에서 권고하는 평균유선선량은 3 mGy이하이지만 이는 유방의 두께에 따라 다르므로 모든 경우에 권고수치가 넘지 않는다고 해서 적다고 말할 수는 없다. 일반적으로 방사선 촬영에 사용되는 선질은 영상의 화질과 피폭선량을 결정하는 중요한 인자로 촬영 관전압과 부가필터에 영향을 받는다. 일반적으로 유방촬영용장치에서 방출되는 X선 에너지는 연속 스펙트럼(spectrum)으로서 영상의 화질에 미치는 영향이 적은 저 에너지부터 이미지상의 대조도(contrast)를 저해하는 고 에너지 성분까지 포함하고 있다[1,3]. 현재 유방촬영용장치에 많이 사용되고 있는 부가필터는 몰리브덴(molybdenum, Mo), 로듐(rhodium, Rh)등이 있으며, 이는 사용되어지는 X선질의 에너지 영역에 따라 구분하여 사용되고 있다. 현재 유방촬영용장치에 가장 많이 사용되어지고 있는 부가필터의 물질인 몰리브덴(Molybdenum, Mo), 로듐(rhodium, Rh)외에 원자번호와 K-흡수단 영역이 비슷한 니오븀(niobium, Nb)이나 지르코늄(zirconium, Zr)재질의 부가여과판을 사용 하였을때 화질과 선량의 개선된 변화를 알아보고, X선의 저에너지를 흡수할 수 있는 알루미늄(aluminum, Al)재질을 복합으로 사용하였을 때 유방촬영용장치의 화질에 손실없이 알루미늄(aluminum, Al)두께에 따른 조사선량의 경감 정도를 확인하려 한다. 본 실험에서는 몰리브덴(molybdenum, Mo), 니오븀(niobium, Nb), 지르코늄(zirconium, Zr)등의 부가필터를 종류별로 단일필터로 사용할 경우와 이들 단일필터에 알루미늄(aluminum, Al)필터를 복합으로 사용한다. 이 경우 상기 부가필터의 종류에 따른 화질의 개선이 될 것으로 판단되고, 알루미늄(aluminum, Al)필터를 복합으로 사용함으로 인해 저 에너지의 불필요한 X선이 흡수되므로 동일한 농도가 되었을 때 화질에 큰 영향없이 선량이 감소될 것으로 기대된다.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

듀얼 에너지 감산기법을 이용한 디지털 X-ray 영상 최적화에 관한 연구 (Optimization Study of Digital X-ray Imaging with Dual Energy Subtraction Method)

  • 김대호;이용구;이영진
    • 전자공학회논문지
    • /
    • 제53권10호
    • /
    • pp.138-142
    • /
    • 2016
  • 듀얼 에너지 디지털 촬영법 (dual-energy digital radiography, DEDR)은 에너지 감산법을 이용하여 신체 내 병변을 감지하는 데 사용 되어 왔다. 본 연구에서는 DEDR을 이용하여 관전압과 부가필터와 같은 물리적 인자를 변화시킴으로써 최적의 뼈와 조직 영상을 획득하고, SRS-78 프로그램으로 예측한 값과 비교하고자 한다. 에너지 감산법을 이용하여 뼈와 조직의 분리된 영상을 획득하기 위하여 다양한 물질의 물리적 인자의 변화에 따른 영상을 구하였다. 연구에 사용된 팬텀은 알루미늄과 polymethyl methacrylate (PMMA)로 구성되었으며, 영상의 최적화는 대조도 대 잡음비 (contrast-to-noise ratio, CNR)로 측정하였다. 실험 결과 50 kVp와 120 kVp 두 영상의 감산 영상이 최적의 뼈와 조직의 분리 영상임을 확인 할 수 있었다. 또한 고 에너지에 10 mm 알루미늄 부가필터를 추가하였을 때, 최적의 뼈와 조직의 분리 효과를 기대 할 수 있었다. 이러한 결과는 실험 전에 SRS-78 프로그램으로 예측한 최적화 조건과 일치함을 알 수 있었다. 본 연구를 통해 관전압이나 부가필터 두께와 같은 물리적 인자를 적절하게 조절한다면 최적의 영상을 얻을 수 있음을 확인하였고, DEDR을 이용하여 원하는 부분만을 표현함으로써 의료영상분야에 기여하고 응용분야를 확장 할 수 있을 것으로 기대한다.

중형 선회 스크롤의 품질 특성 인자에 대한 연구 (The study on the quality characteristics factor of medium-sized orbit scroll)

  • 김재기;임정택;강순국;박종순
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.718-723
    • /
    • 2016
  • 중형 차량용 에어컨에 사용되는 스크롤 압축기는 토크변동이 적고 에너지 효율이 높으며, 소음이 적어 적용이 확대되어 가고 있다. 또한 경량화에 따라 압축기를 구성하는 주요부품이 스틸에서 알루미늄으로 변경하는 등 소재에 대한 연구가 활발히 이루어지고 있다. 또한 스크롤 압축기는 고정 스크롤과 선회 스크롤의 인벌루트 랩의 가공 정밀도가 $10{\mu}m$ 이하로 정밀도가 높은 전용장비와 전용 툴은 물론 숙련된 가공기술이 요구되므로 가공 품질을 확인하기 위하여 표면조도와 윤곽도를 측정하였으며, 알루미늄을 모재로하여 양극 산화 처리하여 사용되고 있는 선회스크롤의 경도를 향상시키기 위한 방법의 일환으로 봉공처리를 수행에 따른 특성들을 살펴보았다. 알루미늄 소재는 Al-Mg-Cu계 합금으로 미량의 Ni, Fe, Zn 이 부가된 것으로 나타났으며, 표면조도는 $3{\mu}m$이하로 가공 정밀도 기준 $10{\mu}m$를 만족하였다. 또한 양극산화 후 나노다이아몬드, CNT로 봉공처리 한 경우 경도는 450 이상으로 수봉공처리의 경우 보다 50% 이상 경도가 향상됨을 알 수 있었으며, 봉공재로 사용하기 위한 소재로서 탄소나노튜브나 나노다이아몬드는 큰 차이를 보이지 않았다.