• Title/Summary/Keyword: Alternative Energy Strategy

Search Result 66, Processing Time 0.019 seconds

Green Marketing Strategy & Alternative Energy Development (그린마케팅전략과 대체에너지개발)

  • Gim, Jin-Goo;Yoon, Dae-Gwun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.237-240
    • /
    • 2011
  • The purpose of this paper is to increase the competitiveness of firms by establishment of green marketing strategy and its application to a new alternative energy development, ultimately contributing to the advancement of national economy. This study adopted an integrated approach to develop a strategic theory of 'Sun Tzu on the Art of War' that is one of the oldest military treaties and still applicable to today's management development. It applies to the empirical result from a new alternative energy development. For more qualitative improvement of this paper, it needs further detailed studies in both theory and practice in green marketing theory that is applicable to the new alternative energy development.

  • PDF

Feasibility Analysis of Alternative Electricity Systems by 2030 in the Post-Fukushima Era

  • Park, Nyun-Bae;Lee, Sanghoon;Han, Jin-Yi;Jeon, Eui Chan
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The Fukushima nuclear accident in 2011 had an extensive impact on the national electricity plans. This paper outlines alternative electricity scenarios that meet the goals of nuclear phase-out and greenhouse gas (GHG) emission reduction. This paper also analyzes the results of each scenario in respect to the electricity mix, GHG emissions, costs and employment effects. The Long-range Energy Alternatives Planning system (LEAP) model was used to simulate the annual electricity demand and supply system from 2011 to 2030. The reference year was 2009. Scenarios are reference (where existing plans are continued), A1, A2, B1, B2, and C2 (where the levels of demand management and nuclear phase-out are different). The share of renewable energy in the electricity mix in 2030 for each scenario will be increased from about 1% in 2009 to 8% in the reference scenario and from 11% to 31% in five alternative scenarios. Total cumulative cost increases up to 14% more than the reference scenario by replacing nuclear power plants with renewable energy in alternative scenarios could be affordable. Deploying enough renewable energy to meet such targets requires a roadmap for electricity price realization, expansion of research, development and deployment for renewable energy technologies, establishment of an organization dedicated to renewable energy, and ambitious targets for renewable energy.

Strategy of Technology Development for the production of EtOH as an Alternative Automobile Fuel. (수송용 대체 에너지-EtOH 생산에 관한 기술개발 전략)

  • 허병기
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.139-153
    • /
    • 1993
  • 20세기 인류가 이룩한 물질문명의 화려한 발전은 물질의 과량소비 에너지의 과다소비 공해물질의 대량배출 등의 바탕 위에 이룩되었다는 것을 아무도 부인하지 못할 것이다. 이 기간 동안 인류의 삶의 질은 향상되었을지 모르나 물질 및 에너지 자원의 고갈 지구환경의 파괴 질병의 유발 등과 같은 풀기 어려운 숙제를 후손들에게 남겨놓게 되었다.

  • PDF

Urban energy transition and energy autonomy in Daegu (대구의 도시 에너지 전환과 에너지 자립)

  • Choi, Byung-Doo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.647-669
    • /
    • 2013
  • Depletion of fossil fuels and sharp rise of international oil price as well as climate worming and frequent environmental disasters have required to strengthen resource(esp. energy) and environmental policy and discourse. And hence highly influential discourses and policies such as the concept of sustainable development and strategy for carbon regulation have been developed and pursued world-widely. But these concept and strategy have seemed to be subsumed in the process of neoliberalism, so as to have little effective results. This leads us to energy transition and energy autonomy or autarky as alternative strategic and normative concepts. Daegu has shown strong interests in urban energy problems relatively earlier than other cities, and developed the so-call 'Solar City' project. But it could not properly tackled with the problems, while tending to meet with the global imperatives. This paper considers urban energy problems and energy policy of Daegu with its significance and limitations, and suggests 4 principles for urban energy transition and autonomy with some concrete alternative measures; that is, the transition from fossil and nuclear energy to renewable energy, the transition from supply-led policy to demand side focusing policy, the transition from central governing energy system to locally distributed one, and the transition from market-dependent management to citizen-participatory energy governance.

  • PDF

An Hourly Operating Strategy for Direct Load Control Resources (직접부하자원의 시간대별 부하배분 전략)

  • Jeong, Sang-Yun;Park, Jong-Bae;Shin, Joong-Rin;Kim, Hyeong-Jung;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.816-818
    • /
    • 2005
  • In this paper, we have developed an hourly operating strategy for Direct load control (DLC) considering the efficiency of DLC program and increasing the utility of DLC resource. According to the operating code for DLC, the DLC center should curtail the load for 4 hours when the control notification has been enforced. Since the above strategy may limit the participation of entities, who intend to take part in the DLC program, the new strategy to mitigate the above limitation is required. In this paper, we have developed the operating strategy of DLC program and the mechanism to apply the proposed strategy in the DLC center. The proposed strategy makes the important role from the view of guaranteing the effective alternative raising the participation and avoiding the penalty of the entities.

  • PDF

Union Substitution Strategy and Human Resource Management by Non-Unionized Valero Energy Co. (비노조기업 Valero Energy의 노조대체전략과 인적자원관리)

  • Lee, Jeonghyun
    • Korean Journal of Labor Studies
    • /
    • v.24 no.2
    • /
    • pp.409-441
    • /
    • 2018
  • This study is a case study about the Valero Energy Corporation, the largest American independent refinery company, examining the characteristics of human resource management as a union avoidance strategy. The main research questions here are whether union substitution strategy differs clearly from union suppression strategy in the context of Valero Energy. Since the establishment in 1980, the Valero had maintained non-union tradition. The typical examples of human resource management in the non-unionized American companies are easily found in the Valero, such as strong CEO leadership, manpower policy emphasizing corporate culture and teamwork, direct communication between company and individual employees, no lay-off policy and no outsourcing policy of HRM, salary level around average of industry and best level of fringe benefits in the industry, non-union tradition and well-functioned alternative dispute resolution system and so on. Until now, based on tremendous growth and profitability, the company have applied union substitution method adopted by good companies as concrete method of union avoidance strategy instead of union suppression method that marginal enterprise prefers.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

Trend on Technology Development of Bioenergy from Woody Biomass (목질계 바이오매스를 이용한 바이오에너지 기술개발 동향)

  • Kwon, Gu-Joong;Kim, Nam-Hun
    • Journal of Forest and Environmental Science
    • /
    • v.25 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • Recently, various efforts for the extended utilization of woody biomass has been attempted due to the fact that global warming, energy and environmental problems are urgent ones to be solved. Development of new energy sources at our national security level is desperately needed as we depend on almost all of energies supplied from other countries, let alone the economic crisis caused by oil price hike. Woody biomass can be converted to energy by means of thermochemical, biological, or direct combustion processes. Many processes are available for producing bioenergy, such as bioethanol, wood pellet, wood chip, combined heat, and power system. Political support and R&D investment should be provided that can boost the utilization of the wood biomass, the eco-environment, and recyclable and alternative energy resources for national power security. In addition, a long-term strategy that can utilize unused and low efficient woody biomass resources, and systematically collect and manage them in a national level should be set up. Even though the possibility in total exchange of fossil oil with woody biomass is quite low, technology developments of woody biomass for the solution to global warming and environmental problem through its commercialization are expected to grow steadily.

  • PDF

An Evaluation on the Effect of the MSW-RDF Power Generation on the Thermal Efficiency and $CO_2$ Reduction (RDF발전에 의한 열효율향상 및 $CO_2$삭감효과에 대한 평가)

  • Choe, Gap-Seok;Choe, Yeon-Seok;Kim, Seok-Jun;Gwon, Yeong-Bae
    • 연구논문집
    • /
    • s.31
    • /
    • pp.45-51
    • /
    • 2001
  • One of emerging technologies under development in the advanced countries is considered as RDF(Refuse Derived Fuel) power generation, which could meet both the requirement of an alternative energy resource utilization and $CO_2$ reduction. This paper deals with the effect to the thermal effiency and CO2 reduction of RDF firing power generation. The statistical data of domestic MSW generation in last year in small and medium cities for evaluating the merits of the RDF power generation were used. The analysis for RDF power generation compared to the existing incinerator w/o(or w/) power generation shows around 20.6%(10.0%) up in the total thermal efficiency and 57.0%(31.4%) up in the $CO_2$ reduction respectively.

  • PDF

A Smooth LVRT Control Strategy for Single-Phase Two-Stage Grid-Connected PV Inverters

  • Xiao, Furong;Dong, Lei;Khahro, Shahnawaz Farhan;Huang, Xiaojiang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.806-818
    • /
    • 2015
  • Based on the inherent relationship between dc-bus voltage and grid feeding active power, two dc-bus voltage regulators with different references are adopted for a grid-connected PV inverter operating in both normal grid voltage mode and low grid voltage mode. In the proposed scheme, an additional dc-bus voltage regulator paralleled with maximum power point tracking controller is used to guarantee the reliability of the low voltage ride-through (LVRT) of the inverter. Unlike conventional LVRT strategies, the proposed strategy does not require detecting grid voltage sag fault in terms of realizing LVRT. Moreover, the developed method does not have switching operations. The proposed technique can also enhance the stability of a power system in case of varying environmental conditions during a low grid voltage period. The operation principle of the presented LVRT control strategy is presented in detail, together with the design guidelines for the key parameters. Finally, a 3 kW prototype is built to validate the feasibility of the proposed LVRT strategy.