• Title/Summary/Keyword: Alpha imaging

Search Result 216, Processing Time 0.025 seconds

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF

과학기술위성 3호 주탑재체 MIRIS 개발 현황

  • Han, Won-Yong;Lee, Dae-Hui;Park, Yeong-Sik;Jeong, Ung-Seop;Lee, Chang-Hui;Mun, Bong-Gon;Park, Seong-Jun;Cha, Sang-Mok;Pyo, Jeong-Hyeon;Ga, Neung-Hyeon;Lee, Deok-Haeng;Park, Jang-Hyeon;Seon, Gwang-Il;Nam, Uk-Won;Yang, Sun-Cheol;Lee, Seung-U;Park, Jong-O;Lee, Hyeong-Mok;Toshio, Matsumoto
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.55.2-55.2
    • /
    • 2010
  • 한국천문연구원은 과학기술위성 3호의 주탑재체인 다목적 적외선영상시스템(Multipurpose Infra-Red Imaging System, MIRIS)을 개발하고 있다. 이 연구개발 사업은 2007년 교육과학기술부의 과학위성 3호 사업 주탑재체 공모를 통하여 10여개의 후보 탑재체 제안서 중에서 최종적으로 채택되었고, 2011년 발사를 목표로, 3년 동안의 연구개발 기간을 거쳐 현재 비행모델 (FM, Flight Model) 개발이 진행 중이다. MIRIS는 한국천문연구원이 개발하여 2003년 발사에 성공한 과학위성 1호 주탑재체인 원자외선 영상분광기 (FIMS, Far ultra-violet IMaging Spectroscope)에 이어 국내에서 자체 개발되는 두 번째 우주망원경이다. MIRIS는 우주공간에서 0.9~2 micron 사이 적외선 영역의 파쉔 알파 방출선 (Paschen Alpha Emiision Line)과 광대역 I, H 파장영역을 관측할 예정이다. 주요 과학임무로는 아직까지 국제 천문학계에서 잘 알려지지 않은 우리은하 내부에 분포한 고온 플라즈마 (Warm Ionized Medium, WIM)의 기원 연구와 아울러 우리은하 성간난류(Interstellar Turbulence)의 특성 및 적외선 우주배경복사의 (Cosmic Infrared Background; CIB) 거대구조 등을 관측연구할 예정이다. 특히 MIRIS는 저온상태 (절대온도 77K, 약 $-200^{\circ}C$)에서 우주공간 관측을 수행할 예정이므로, 국내에서는 연구기반이 취약한 극저온 광학계 및 기계부 설계기술, 극저온 냉각기술 및 열해석 설계기술과 적외선 센서기술 및 자료처리 기술 등 관련기술을 개발하고 있으며 이러한 기반기술을 바탕으로, 아직까지 국내에서 시도된 바 없는 적외선우주망원경 개발을 통하여, 우리나라의 관련 우주기술 분야의 기초원천 기술로서 크게 활용될 것으로 기대하고 있다.

  • PDF

Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles (Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석)

  • Ryu, Young-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Choi, Sung-Hyun;Jang, Young-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

Tiny Pores Observed by New Solar Telescope and Hinode

  • Cho, Kyung-Suk;Bong, Su-Chan;Chae, Jong-Chul;Kim, Yeon-Han;Park, Young-Deuk;Ahn, K.;Katsukawa, Y.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.37.2-37.2
    • /
    • 2011
  • Our previous study on tiny pores (R < 2") observed by HINODE/Solar Optical Telescope (SOT) revealed that the plasma in the pores at the photosphere is always moving down and the pores are surrounded by the strong downward motions (highly red-shifted) of neighboring granulations. From this study, we speculated that the flow motions above the pore should be related with the motions at the photosphere, since the pore is strong magnetic field region. Meanwhile, SNU and KASI installed Fast Imaging Solar Spectrograph (FISS) in the Cude room of the 1.6 m New Solar Telescope (NST) at Big Bear Solar Observatory. FISS is a unique system that can do imaging of H-alpha and Ca II 8542 band simultaneously, which is quite suitable for studying of dynamics of chromosphere. To get some clue on the relationship between the photospheric and low-chromospheric motions at the pore region, we took a coordinate observation with NST/FISS and Hinode/SOT for new emerging active region (AR11117) on October 26, 2010. In the observed region, we could find two tiny pores and two small magnetic islands (SMIs), which have similar magnetic flux with the pores but does not look dark. Magnetic flux density and Doppler velocities at the photosphere are estimated by applying the center-of-gravity (COG) method to the HINODE/spectropolarimeter (SP) data. The line-of-sight motions above the photosphere are determined by adopting the bisector method to the wing spectra of Ha and CaII 8542 lines. As results, we found the followings. (1) There are upflow motion on the pores and downflow motion on the SMIs. (2) Towards the CaII 8542 line center, upflow motion decrease and turn to downward motion in pores, while the speed of down flow motion increases in the SMIs. (3) There is oscillating motion above pores and the SMIs, and this motion keep its pattern along the height. (4) As height increase, there is a general tendency of the speed shift to downward on pores and the SMIs. This is more clearly seen on the other regions of stronger magnetic field. In this talk, we will present preliminary understanding of the coupling of pore dynamics between the photosphere and the low-chromosphere.

  • PDF

Role of Chemical Exchange Saturation Transfer and Magnetization Transfer MRI in Detecting Metabolic and Structural Changes of Renal Fibrosis in an Animal Model at 3T

  • Anqin Li;Chuou Xu;Ping Liang;Yao Hu;Yaqi Shen;Daoyu Hu;Zhen Li;Ihab R. Kamel
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.588-597
    • /
    • 2020
  • Objective: To investigate the value of combined chemical exchange saturation transfer (CEST) and conventional magnetization transfer imaging (MT) in detecting metabolic and structural changes of renal fibrosis in rats with unilateral ureteral obstruction (UUO) at 3T MRI. Materials and Methods: Thirty-five Sprague-Dawley rats underwent UUO surgery (n = 25) or sham surgery (n = 10). The obstructed and contralateral kidneys were evaluated on days 1, 3, 5, and 7 after surgery. After CEST and MT examinations, 18F-labeled fluoro-2-deoxyglucose positron emission tomography was performed to quantify glucose metabolism. Fibrosis was measured by histology and western blots. Correlations were compared between asymmetrical magnetization transfer ratio at 1.2 ppm (MTRasym(1.2ppm)) derived from CEST and maximum standard uptake value (SUVmax) and between magnetization transfer ratio (MTR) derived from MT and alpha-smooth muscle actin (α-SMA). Results: On days 3 and 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of contralateral kidneys (p < 0.05). On day 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of sham-operated kidneys (p < 0.05). The MTRasym(1.2ppm) of UUO renal medulla was fairly negatively correlated with SUVmax (r = -0.350, p = 0.021), whereas MTR of UUO renal medulla was strongly negatively correlated with α-SMA (r = -0.744, p < 0.001). Conclusion: CEST and MT could provide metabolic and structural information for comprehensive assessment of renal fibrosis in UUO rats in 3T MRI and may aid in clinical monitoring of renal fibrosis in patients with chronic kidney disease.

A Study on the Effect of Erycibae Caulis and Corydalis Tuber Pharmacopuncture on a Mouse Model with Collagen Induced Rheumatoid Arthritis (정공등현호색(丁公藤玄胡索) 약침(藥鍼)이 류마티스 관절염 생쥐 모델에 미치는 영향)

  • Kim, Hyun Ji;Jeon, Ju Hyun;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.21-34
    • /
    • 2016
  • Objectives : The aim of the present study is to examine the effect and mechanism of Erycibae Caulis and Corydalis Tuber Pharmacopuncture (ECP) on a mouse model with collagen induced rheumatoid arthritis (CIA). Methods : We evaluated the Aspartate aminotransferase (AST), Alanine aminotransferase (ALT), Creatinine, and the Blood urea nitrogen (BUN) of serum to examine the safety of this study. In vivo, we compared the results of the non-treated group, the normal saline pharmacopuncture treated control group, the indomethacin treated group and the ECP group. We evaluated rheumatoid arthritis manifestation and the Rheumatoid Arthritis Index (AI). Also, immune cells in blood affected by ECP were evaluated by calculating the level of white blood cells (WBC), neutrophil, lympocytes and monocytes. Next, the level of Immunoglobulin M (IgM), Immunoglobulin G (IgG), Interleukin (IL)-$1{\beta}$, IL-6, IL-17, Tumor Necrosis Factor (TNF)-${\alpha}$ and Granulocyte-macrophage Stimulating Factor (GM-CSF)in serum were measured. We examined the imaging of cartilage degeneration using micro CT-arthrography of the hind paw. Additionally, we examined the effects of reducing bone volume (BV) ratio and bone surface/bone volume (BS/BV) ratio with 3D Micro-CT. Finally, we did a histopathologic examination analysis. Results : The absence of liver and kidney toxicity was evident. In vivo, edema of the joints of the ECP group decreased greatly in macroscopic observation. AI measurement of the ECP group also decreased significantly compared to the control group. The level of WBC, neutrophil, lympocytes, and monocytes in the blood decreased but there was no statistical significance of this data. IgM of the ECP group decreased significantly compared to the control group. IL-$1{\beta}$, IL-6, TNF-${\alpha}$, and GM-CSF production of the ECP group decreased significantly compared to the control group. As a result of examining joint condition with 3D micro CT, deformation and destruction of the joint was shown to have decreased. Bone density of ECP group increased at a statistically significant level compared to the control group. Degree of joint inflammation of ECP group decreased significantly compared to the control group. After H&E and M-T staining, infiltration of immune cells, subsidence of the cartilage, damage to the synovial cells and joint erosion decreased. Conclusion : This study showed that ECP hindered the process of rheumatoid arthritis and protected joints and cartilage.

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Precision Evaluation of Scanning the Digital Dental Abutment Impression and Dental Gypsum Model according to 3-dimensional Superimposing Different Skills (3차원 중첩 기술 차이에 따른 디지털 치과용 지대치 인상체 및 경석고 모형의 스캐닝 정밀도 평가)

  • Jeon, Jin-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.639-645
    • /
    • 2018
  • The objective of this research was to compare the precision of scanning the digital abutment impression and gypsum model according to 3-dimensional superimposing different skills. There were made with the abutment impression and gypsum model of a maxillary 1st premolar, blue light scanner scanned to obtain the stereolithography (STL) file. After the same process was performed 10 more times without moving them on the scanner table about the abutment impression and gypsum model, respectively (n=11, per types). By superimposing the date of scanning the abutment impression and gypsum model used with no control and best-fit-alignment skills, 10 color-difference maps and root mean square (RMS) data were obtained. The independent t-test was performed to compare RMS data between the each other groups (${\alpha}=0.05$). In the scanning abutment impressions, $RMS{\pm}SD$ of no control, best-fit-alignment showed $6.86{\pm}0.94$, $5.04{\pm}0.24$. in the scanning gypsum model, $4.98{\pm}1.16$, $3.39{\pm}0.07$, all groups showed a significant difference (P<0.001). Trough the this study's result, not only best-fit-alignment but no control is used with digital dental computer-aided design/computer-aided manufacturing (CAD/CAM) research and clinical part.

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.