• Title/Summary/Keyword: Allowable load

Search Result 507, Processing Time 0.026 seconds

Experimental study on fatigue behavior of innovative hollow composite bridge slabs

  • Yang Chen;Zhaowei Jiang;Qing Xu;Chong Ren
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.745-757
    • /
    • 2023
  • In order to study the fatigue performance of the flat steel plate-lightweight aggregate concrete hollow composite bridge slab subjected to fatigue load, both static test on two specimens and fatigue test on six specimens were conducted. The effects of the arrangement of the steel pipes, the amplitude of the fatigue load and the upper limit as well as lower limit of fatigue load on failure performance were investigated. Besides, for specimens in fatigue test, strains of the concrete, residual deflection, bending stiffness, residual bearing capacity and dynamic response were analyzed. Test results showed that the specimens failed in the fracture of the bottom flat steel plate regardless of the arrangement of the steel pipes. Moreover, the fatigue loading cycles of composite slab were mainly controlled by the amplitude of the fatigue load, but the influences of upper limit and lower limit of fatigue load on fatigue life was slight. The fatigue life of the composite bridge slabs can be determined by the fatigue strength of bottom flat steel plate, which can be calculated by the method of allowable stress amplitude in steel structure design code.

Structural Safety Evaluation for the Hydraulic Power Unit of Topside Module According to the Movement of Offshore Plant (해양구조물 움직임에 따른 Topside Module의 HPU에 대한 구조안전성 평가)

  • Ryu, Bo-Rim;Lee, Jin-Uk;Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.723-731
    • /
    • 2020
  • The design of offshore plants should reflect the various requirements of the owner and the classification society. For a topside module mounted on an of shore structure, the design process is very demanding because of the large spatial constraints and the many requirements related to marine environmental conditions and safety such as the movement of the structure. In this study, the load acting on the hydraulic power unit, which is one of the main equipment in the topside module, was calculated according to the DNVGL rule; the structural safety was evaluated according to each load condition and the structural reliability of the developed product was improved. For structural analysis, MSC software was used, and structural analysis was performed under five load conditions to review structural safety for various movements. The results show that the maximum stress occurred during pitching toward the stern (Load Case 5). The stress level was approximately 85 % of the allowable stress, and the maximum deformation was approximately 5 % of the allowable value. The structural safety was confirmed, and no intermember interference occurred.

Evaluation on Transverse Load Performance of Lightweight Composite Panels (경량 복합패널의 분포압 강도 성능 평가)

  • Kang, Su-Min;Hwang, Moon-Young;Kim, Sung-Tae;Cho, Young-Jun;Lee, Byung-yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.146-157
    • /
    • 2018
  • Over the last 10 years, the number of disasters has been increasing in Korea. As a result, the need for temporary residences or shelters for disaster conditions is increasing. In this study, post-disaster refugees housing was developed using lightweight composite panels that are lighter than the materials that make up the existing shelter. To accomplish this, the structural performance of the lightweight composite panel was validated. Among the performance tests on the panels, the transverse load test was conducted according to the ASTM E 72 criteria. As a result of the experiment, when each specimen was subjected to a uniformly distributed load, the allowable load was determined according to the span. All the experiments were ended due to a loss of adhesive at the junction of the skin and core. Further analysis was conducted to calculate the shear stress when the junction was dropped. The mean shear stress at the adhesive surface of a specimen, 150 mm and 200 mm in thickness, was 0.0170MPa and 0.0156MPa, respectively. This suggests that similar values were obtained from panels of equal thickness. In addition, this stress provides a criterion of judgment that could be used to inspect the structural performance of the panels. The performance of the panel was evaluated based on the allowable load, but it may be possible to increase the strength of the lightweight composite panel by improving the joining method to avoid separation from the junction.

The Estimation of Fatigue Design Strength on Base Metal and Welded Parts of Rail (철도궤조(鐵道軌條) 및 용접연결부(鎔接連結部)에 대한 피로설계강도(疲勞設計强度)의 평가(評價))

  • Yong, Hwan Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.109-116
    • /
    • 1988
  • The strength and load of structure are varied with the Passage of time, and become a process of probability. It is possible to estimate the reliability from the relation between strength and load. Considering the safety, It is reasonable to estimate allowable stress from the safety factor based on the reliability. In this study, the method to estimate probability of fracture, which is index of reliability for rail subjeict to long term fatigue load were examined. In estimation of reliablity it is meaningless to evaluate numerical value especially this difficult case estimating parameter of random variable. To overcome this problem, conventional design method estimating relative reliability were proposed. In this study the Cornell method were examined. The uncertainity of random variale, ie coefficient of variation which is the index of variation of strength and load were considered. The effect of uncertainity related to probability of fracture, and safety factor based on reliability were examined. The results of this study are followed. The reliability of weld metal were influenced by variation of strength more then load, and base metal were influenced by load. It is confirmed that the allowable stress range calculating with factor of safety based an reliability is conservative.

  • PDF

Performance Evaluation of Pile-Filling Material Using High Calcium Ash by Field Loading Test (고칼슘 연소재를 이용한 매입말뚝 주면고정액의 현장 재하시험을 통한 성능평가)

  • Seo, Se-Kwan;Kim, You-Seong;Lim, Yang-Hyun;Jo, Dae-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.17-24
    • /
    • 2018
  • In this study, static load test and dynamic load test were performed to evaluate pile-filling material (ZA-Soil) of soil-cement injected precast pile method which was developed by using the ash of circulating fluidized boiler as a stimulant for alkali activation reaction of blast furnace slag. As a result of the static load test, the allowable bearing capacity of pile was 1,350 kN, which was the same as the result of using ordinary portland cement. And total settlement was 6.97 mm, and net settlement was 1.48 mm. These are similar to the total settlement, 7.825 mm, and net settlement, 2.005 mm of ordinary portland cement. As a result of the dynamic load test and CAPWAP analysis, the skin friction was 375.0 kN, the end bearing capacity was 3,045.9 kN, and the allowable bearing capacity was 1,368.36 kN. These results are similar to the results of using ordinary portland cement as pile-filling material.

Study on the Characteristic of System Frequency Decay In Case of Large Generator Unit Outage (전원탈락에 따른 계통주파수저하문제검토 제1보)

  • 송길영
    • 전기의세계
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 1969
  • According to the construction of Seoul Thermal #5 (250MW) unit, there will be prospected several new problems on the power system operation. This paper describes the characteristic of system frequency decay during severe emergencies which result in sudden outage of such large generator unit. It also studies the factors involved in applying under frequency relays to maintan an allowable frequency level and to prevent total area collapse by automatic load shedding program.

  • PDF

Vibration Analysis of Composite Satellite Antenna by Acoustic Excitation (음향 가진에 의한 위성 안테나의 진동해석)

  • ;;;;;Horst Stockburger
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.123-126
    • /
    • 2002
  • Acoustic vibration analysis has been performed using random vibration analysis module of MSC/NASTRAN to evaluate the safety of the composite satellite antenna structure under the acoustic pressure from the launch vehicle. It was found that maximum $3\sigma$ stress by acoustic excitation was less than allowable stress.

  • PDF

Speed Control of the Motor in Automatic Control Using the Thyristor (싸이리스터에 의한 전동기 속도의 자동제어에 관한 연구)

  • Min Ho Park
    • 전기의세계
    • /
    • v.19 no.2
    • /
    • pp.6-11
    • /
    • 1970
  • For the variable speed in automatic control, this paper describes, at first, performance equations of an induction motor which has the free rotating stator. This motor with rotating stator has a speed control factor itself by equivalent variable frequency in stator side. Secondly, an additional invertor source on the rotor slip ring serves the purpose of improving the speed control factor. The advantages decribed above permit to control the speed continuosly from zero to maximum allowable speed with low energy of thyristor a feed-back device may be used for speed stabilization under variable load.

  • PDF

Anattical Perfowmnce Modeling of Multi-class QoS IP Router (다중클래스 QoS를 지원하는 IP라우터의 성능분석을 위한 해석적 모델의 구현)

  • 진승의;김태일;이형호
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.257-260
    • /
    • 2001
  • As today's network infrastructure continues to grow and DiffServ IP networks ate now available to provide various levels of flexible QoS services. DiffServ guarantees good scalability but shows dynamic QoS dependent on network traffic loads. Therefore, in this paper, we investigate the dynamics of DiffSev QoS and present analytical model to estimate the allowable traffic load under the given network conditions.

  • PDF

A Study on the two span preflex composite girder bridges with LRFD (LRFD에 의한 2경간 Preflex 합성형교에 관한 연구)

  • 구민세;박영제;오석태
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.95-102
    • /
    • 1999
  • Preflex beams are prestressed by the predeflection technique, which enables the use of concrete-encased high strength steel beams where deflection or cracking of concrete, or both, would otherwise be excessive. This study presents the analysis of the two span preflex composite girder bridges with Load and Resistance Factor Design(LRFD), which is most widely used design nile in the advanced states. The results show that the comparison of LRR with Allowable Stress Design(ASD) according to span length.

  • PDF