• Title/Summary/Keyword: Allowable Vibration

Search Result 197, Processing Time 0.021 seconds

The Prediction of Allowable Limit Distance about Human Body by Vibration Regulation (진동 규제기준에 따른 인체의 허용 한계거리 예측)

  • Song, Jeong-Un;Hong, Woong-Ki;Kim, Seung-Kon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.289-296
    • /
    • 2012
  • The shock vibration such as machine vibration, blasting vibration etc. has effect on nearby structure as well as human body. The purpose of this study is to predict allowable limit distance of vibration about human body. First of all, vibration velocity such as PPV, PVS was measured by shock vibration experiment, and vibration level was calculated by conversion formula of vibration velocity. And then, allowable limit distance was analyzed by converted vibration level. The results are as follows : Firstly, the correlation coefficient of converted vibration level was over R=0.94, and vibration level caused by PVS was usually represented to high curve line. Secondly, the cross point of vibration level between ground and concrete condition was represented to 66.68dB(V), and allowable limit distance was represented to difference over three times when vibration regulation was raised from 65dB(V) to 80dB(V).

A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions (발파진동 제어에 의한 특수구간 터널굴착에 관한 연구)

  • Choi, Hyung-Bin;Lim, Han-Uk
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

On the study of the measurement of blasting Vibration and Sound influenced to housing structure at Wire-Tunnelling (부산 통신구굴진 발파작업으로 인한 지상주택 구조물에 미치는 진동폭음영향계측조사보고)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1990
  • The Caustious blasting have often increased Complaints of ground Vibration and Sound when the Wire-Tunnel Constructed in Pusan. In order to prevent the influence to housing structure, it was necessary to predict blasting-Induced Vibration and Sound. The Suveyer determined the Burden and spacing of Drill holes, minimum delay charges within a allowable Vibration and Sound Level. Tunnel drilling and Ignition patterns are made as follows; No. 1 Tunel (Stable rock, hard rock) No.2 Tunnel (Instable plastic rock; wethered rock) and other Tunnels (Instable rock). The result of 1st testing blasting of No. 1 Tunnel was recorded Under allowable Vibration Level but sound was over 75 Db of allowable value. So Tunnel drilling pattern was amended with 52 Non-charg holes to reduce the blast-sound. The other pattern had no need to amend.

  • PDF

A Dynamic Structure Design of PC type Sub-structure for next Semi-conduct, TFT-LCD Fab based on Dynamic Test and Simulation (차세대 반도체, TFT-LCD Fab 구조설계를 위한 PC형 격자보에 대한 동적 특성 평가 및 개선방안)

  • 손성완;김강부;전종균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.237-242
    • /
    • 2004
  • In design stage of high precision manufacture/inspection FAB building, it is necessary to investigate the vibration allowable limits of high precision equipment and to study a structure dynamic characteristics of C/R and Sub-structure in order to provide a structure vibration environment to satisfy thess allowable limits. The aim of this study is to investigate the dynamic characteristics of PC-Type mock-up structures designed for next TFT LCD FAB through vibration measurement and analysis procedure, therefore, to provide a proper dynamic structure design for high precision manufacture/inspection work process, which satisfy thess allowable limits.

  • PDF

Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System (고압급수가열기 배수계통 배관계 고진동 해소방안 연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Sang-Bok;Hong, Soon-Bup;Shin, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

A Study on the Dynamic Design of Anti-Vibration Structures for Nano-class Measuring System (나노 측정시스템을 위한 방진 구조물의 동적 설계에 관한 연구)

  • 전종균;김강부;백재호
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.3
    • /
    • pp.37-43
    • /
    • 2003
  • It is necessary to design the anti-vibration system of precision machinery for a quality assurance. However, in general, the allowable vibration limit is not well known. In this paper, the vibration criteria for foundation of sensitive machinery is proposed and anti-vibration system is designed by using vibration measurement results of foundation. Also, the finite element analysis is performed to verify the effectiveness of the designed anti-vibration system and to determine the allowable dynamic loads of precision measuring system. The results of this study will be helpful for the future design of anti-vibration structures with nano scale measuring system.

  • PDF

A Study on the Dynamic Design of Structure for Sub-Vibration Control of Precision Measuring System (극 초정밀 측정시스템의 미진동제어를 위한 구조물의 동적 설계에 관한 연구)

  • 김강부;김현식;전종균;김기현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.863-868
    • /
    • 2001
  • It is necessary to design th anti-vibration system of precision machinery for a sound operation and a quality assurance. However, in general. the allowable vibration limit is not well known. In the paper, the vibration criteria for foundation of vibration sensitive machinery is proposed and anti-vibration system is designed by using vibration measurement results of foundation. Also, the F.E. analysis is performed to verify the effectiveness of a designed anti-vibration system and to determine allowable dynamic load of machinery

  • PDF

A Dynamic Structural Design of PC type Sub-Structure for Next-Generation FAB based on Dynamic Test and Simulation (차세대 반도체 FAB의 동적 구조 설계를 위한 PC형 격자보 구조물의 동적 특성 평가)

  • 전종균;김강부;손성완;이홍기
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.4
    • /
    • pp.51-55
    • /
    • 2004
  • In the design stage of high precision manufacturing/inspection FAB facilities, it is necessary to investigate the allowable vibration limits of high precision equipments and to study structural dynamic characteristics of C/R and Sub-structure in order to provide structural vibration criteria to satisfy these allowable limits. The goal of this study is to investigate the dynamic characteristics of PC-Type mock-up structures designed for next generation TFT-LCD FAB through experiments and analysis procedures. Therefore, in order to provide a proper dynamic structural design for high precision manufacturing/inspection work process, these allowable limits must be satisfied.

  • PDF

초정밀 반도체 및 TFT-LCD FAB 동적 구조 설계를 위한 PC형 격자보 구조물의 동적 특성 평가 및 개선 방안

  • 손성완;김강부;전종균
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.195-201
    • /
    • 2004
  • In design stage of high precision manufacture/inspect ion FAB building, it is necessary to investigate the vibration allowable limits of high precision equipment and to study a structure dynamic characteristics of C/R and Sub-structure in order to provide a structure vibration environment to satisfy thess allowable limits. The aim of this study is to investigate the dynamic characteristics of PC-Type mock-up structures designed for next TFT LCD FAB through vibration measurement and analysis procedure, therefore, to provide a proper dynamic structure design for high precision manufacture/inspection work process, which satisfy thess allowable limits.

  • PDF