• 제목/요약/키워드: All-in-one dentin adhesive

검색결과 86건 처리시간 0.036초

상아질 접착제의 미세누출과 변연부 혼화층 (MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES)

  • 조영곤;김영관;안종모
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구 (Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin)

  • 최용훈;배지현;손호현;이인복;백승호;엄정문;김오영;김창근;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.177-184
    • /
    • 2004
  • 본 연구는 광중합형 상아질 접착제에서 광조사 시간의 증가가 접착제 표면의 미중합층에 대한 영향과 그에 따른 전단접착강도에 대해 연구하고자 120개의 치아를 아크릴 몰드에 식립한 후 상아질이 노출되도록 연마하였다. 3종류의 접착제 〔All Bond2 (AB2), One-Step (OS) and Adper Prompt (AP)〕를 40개 치아에 제조사의 지시대로 도포한 후 각각 다른 광조사 시간 (10, 20, 30 and 60sec)동안 광조사 하고 복합레진을 접착한 24시간 후 전단접 착강도를 측정하였다. 미중합층의 두께와 중합률은 슬라이드 글라스와 FT-NIR을 이용하여 FT-NIR spectrum에서의 peak height를 비교 측정하여 다음과 같은 결론을 얻었다. 1. 전단접착강도에서 AB2는 20초 이후 감소하고, AP는 30초까지 증가하였으며,OS는 차이를 보이지 않았다. 2. 미중합층 두께는 3가지 접착제 모두 유의성 있는 차이를 보이지 않았다. 3. 중합률에서 OS는 10초와 나머지군 사이에 유의성 있는 차이를, AP는 60초에서 유의성 있게 증가되고, AB2의 경우 차이를 나타내지 않았다.

자가 중합 복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와 흐름성 레진의 효과 (EFFECT OF AN INTERMEDIATE BONDING RESIN AND FLOWABLE RESIN ON THE COMPATIBILITY OF TWO-STEP TOTAL ETCHING ADHESIVES WITH A SELF-CURING COMPOSITE RESIN)

  • 최속경;염지완;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.397-405
    • /
    • 2009
  • 이 연구의 목적은 자가 중합복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와흐름성 레진의 효과를 미세 인장 결합 강도를 통해 비교하는 것이었다. 20개의 발거된 대구치를 사용해 접착제와 부가적인 적용(활성제, 중간 접착제, 흐름성 레진)에 따라 XP bond 그룹 (XA, XB, XF 그룹), Prime & Bond NT 그룹 (NA, NB, NF 그룹), Optibond solo plus 그룹 (OA, OB OX 그룹)으로 나누었다. 접착제 적용 후 활성제, 중간 접착제, 흐름성 레진을 각각 적용하고 상부에 자가 중합 레진을 축성하였다. 24시간 동안 실온의 증류수에 보관 후 각 그룹당 10개의 시편을 준비하였다. 모든 시편의 미세인장 결합 강도를 측정하여 다음과 같은 결과를 얻었다. 1. 모든 그룹에서 중간 접착제와 흐름성 레진의 적용은 활성제 적용보다 더 높은 결합 강도를 보였다. 2. 선택된 방법에 관계없이, Optibond solo plus 그룹은 가장 낮은 미세인장 결합강도를 보였다. 3. 파절 양상은 대부분 접착성 파절을 보였고 일부 레진 내에서 응집성 파절을 보였다. 이번 연구의 결과로부터, 중간 접착제와 흐름성 레진의 적용이 낮은 pH를 가지는 두 단계 산 부식 접착제와 자가 중합복합 레진의 상아질 접착에 더 효과적이라 예상된다.

타액 오염이 One bottle 상아질 결합제의 전단결합강도에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF SALIVA CONTAMINATION ON THE BOND STRENGTH OF ONE-BOTTLE ADHESIVE SYSTEM)

  • 전형준;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.566-574
    • /
    • 2001
  • 법랑질과 상아질에 대한 접착시스템의 결합력은 타액이나 혈액에 의하여 저하될 수 있다. 제 5세대 상아질 결합제 적용시에 산부식된 치면이 타액에 오염될 경우, 보다 효율적인 치면 처리 방법을 알아보기 위해 여러 가지 치면 처리 방법과 조건을 설정한 다음 수복물의 유지력을 전단결합강도 측정으로 서로 비교 분석하고, 치아와 수복물 사이의 계면을 주사전자 현미경을 이용해 관찰하였다. 그 결과 우치상아질의 산부식후 타액오염된 경우, 물로 10초간 세척한 후 공기로 가볍게 건조하여 수복하면 전단결합강도의 감소가 일어나지 않았으나, Prime & Bond NT의 광중합후에 타액오염된 경우에는 물로 10초간 세척한 후 공기로 완전히 건조를 하여도 레진과의 결합력이 매우 약해지며 Prime & Bond NT를 재적용하더라도 전단결합강도의 상당한 감소를 보였으며, 주사전자 현미경 관찰결과 모든 군에서 유사한 혼화층과 레진태그의 형성을 보였으며 특이할만한 각 군간의 차이를 관찰할 수 없었다.

  • PDF

The effects of dentin bonding agent formulas on their polymerization quality, and together with tooth tissues on their microleakage and shear bond strength: an explorative 3-step experiment

  • Erfan, Mohmmad;Jafarzadeh-Kashi, Tahereh Sadat;Ghadiri, Malihe;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.333-345
    • /
    • 2014
  • PURPOSE. Bonding agents (BA) are the crucial weak link of composite restorations. Since the commercial materials' compositions are not disclosed, studies to formulize the optimum ratios of different components are of value. The aim of this study was to find a proper formula of BAs. MATERIALS AND METHODS. This explorative experimental in vitro study was composed of 4 different sets of extensive experiments. A commercial BA and 7 experimental formulas were compared in terms of degree of conversion (5 experimental formulas), shear bond strength, mode of failure, and microleakage (3 experimental formulas). Statistical analyses were performed (${\alpha}$=.05). The DC of selected formula was tested one year later. RESULTS. The two-way ANOVA indicated a significant difference between the shear bond strength (SBS) of two tissues (dentin vs. enamel, P=.0001) in a way that dentinal bonds were weaker. However, there was no difference between the four materials (P=.283). The adhesive mode of failure was predominant in all groups. No differences between the microleakage of the four materials at occlusal (P=.788) or gingival (P=.508) sites were detected (Kruskal-Wallis). The Mann-Whitney U test showed a significant difference between the microleakage of all materials (3 experimental formulas and a commercial material) together at the occlusal site versus the gingival site (P=.041). CONCLUSION. A formula with 62% bisphenol A-glycidyl methacrylate (Bis-GMA), 37% hydroxy ethyl methacrylate (HEMA), 0.3% camphorquinone (CQ), and 0.7% dimethyl-para-toluidine (DMPT) seems a proper formula for mass production. The microleakage and SBS might be respectively higher and lower on dentin compared to enamel.

Effect of Dentin Bonding Agent Acidity on Surface Microhardness of Mineral Trioxide Aggregate

  • Yun-Hui Im;Yoon Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.36-44
    • /
    • 2024
  • Purpose: This study investigated the effect of dentin bonding agent acidity on surface microhardness of MTA. Materials and Methods: Forty cylindrical molds (3 mm×5 mm) were prepared, and three dentin bonding agents with different acidities: Adper Single Bond 2 (ASB), Single Bond Universal (SBU), and Clearfil SE bond 2 (CSE) were applied to the inner surface of the molds (n=10). No bonding agent was applied in the control group. MTA was mixed and inserted into the molds and sealed with a wet cotton pellet for 4 days. After setting, the Vickers microhardness (HV) test was done at 200, 400, 600 ㎛ from the inner surface of the mold. One-way ANOVA was conducted for all samples. A P-value of less than .05 was considered significant. Tukey HSD test was performed for post-hoc analysis. Results: The mean HV values and standard deviations were 67.02±11.38 (Con), 48.76±11.33 (ASB), 43.78±11.19 (CSE), 37.84±9.36 (SBU), respectively. The difference between the control group and the experimental groups was statistically significant (P<0.001). The difference between ASB and SBU was statistically significant (P<0.001), while the difference between SBU and CSE was not. There were no statistically significant differences between the various points from the inner surface of the mold within each group (P>0.05). Conclusion: Results of the current study indicate that use of dentin bonding agents with MTA can reduce the surface microhardness of MTA. Moreover, there is a direct relationship between the acidity of dentin bonding agents and the surface microhardness of MTA.

우치에 대한 All-in-one 상아질 결합제의 전단결합강도 비교 연구 (STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM)

  • 박형주;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.661-672
    • /
    • 2006
  • 우치 60개를 준비하여 법랑질과 상아질에 대하여 각각 1군 AQ Bond, 2군 AQ Bond $Plus^{TM}$, 3군 Single $Bond^{TM}$로 설정하고, 군당 10개씩 배정하였고, 군당 혼화층 관찰에 5개와 resin tag 관찰을 위해 5개씩 배정하였다. 준비된 우치의 법랑질과 상아질을 노출시킨 후 제조사의 지시에 따라 표면을 처리하고, 내경 3mm의 폴리에틸렌 튜브를 이용하여 $Z-250^{TM}$ 복합레진 접착을 시행하였다. 100% 습윤 상태에서 24시간동안 보관 후 $5^{\circ}C$$55^{\circ}C$ 조건하에서 500회 열순환을 시행하였다. 만능시험기를 분당 cross head speed 5mm 속도로 설정하고 100kg F load cell을 사용하여 전단결합강도를 측정하고 파절된 시편들을 수거하여 주사전자현미경으로 파절면을 관찰하였다. 혼화층과 resin tag 관찰을 위하여 상아질 접착면에 대해 수직으로 절단하고 인산과 질산으로 처리한 후 주사전자현미경으로 관찰하였다. 이상의 결과를 토대로 행동 조절에 어려움이 많은 소아 환자의 복합레진 수복시 적용 과정 및 시간 단축이 장점으로 부각되고 있는 all-in-one system의 임상 적용 가능성을 평가하고 다음과 같은 결론을 얻었다. 1. 전단 결합 강도 측정결과 1군, 2군 간에는 유의차가 없었으나, 3군이 1군과 2군에 비해 높은 전단 결합 강도를 보였으며 통계학적 유의차를 보였다 (p<0.05). 2. 파절 양상 관찰 결과 1군과 2군의 법랑질과 상아질 모두에서 그리고 3군의 상아질에서 주로 adhesive fracture 양상을 보였으며, 3군 법랑질에서 각각 cohesive와 adhesive fracture가 균등한 분포를 보였다. 3. 주사 전자 현미경 소견에서 1군과 2군은 resin tag형성이 매우 미약하고 불규칙한 양상을 보인 반면, 3군에서는 비교적 긴밀하게 형성된 resin tag이 관찰되었으며 resin tag의 표면에 형성된 뚜렷한 측부 가지들도 발견되었다.

  • PDF

The effect of additional etching and curing mechanism of composite resin on the dentin bond strength

  • Lee, In-Su;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.479-484
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS. Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ${\times}20$ magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (${\alpha}$=.05). RESULTS. Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION. The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.

수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구 (MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS)

  • 최상철;박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

Benzalkonium Chloride가 NTG-GMA/BPDM계 및 DSDM계 상아질접착제의 접착성능에 미치는 영향 (EFFECT OF BENZALKONIUM CHLORIDE ON DENTIN BONDING WITH NTG-GMA/BPDM AND DSDM SYSTEM)

  • 신일;박진훈
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.699-720
    • /
    • 1995
  • 본 연구는 양이온 계면활성효과를 가져 소독제로 사용되고 있는 benzalkonium chloride 수용액을 상아질 표면에 대한 습윤용 처리제로 적용시킬 경우 상아질접착제의 접착성능에 미치는 영향을 관찰하기 위해 시행되었다. 소의 하악전치 80개를 8개군으로 분류하여 순면의 상아질을 노출시켜서 산처리한 후 물로 습윤 상태를 유지시킨 대조군과 0.1%, 0.5% 및 1% 농도의 benzalkonium chloride 수용액으로 습윤시킨 실험군으로 나누어 NTG-GMA/BPDM계 상아질접착제인 All-bond 2와 DSDM 계 상아질접착제인 Aelitebond를 각각 접착시킨 후 접착시험을 시행하였다. 상아질 표면을 10% 인산수용액으로 처리한 후 습윤과정을 거친 시편을 각 접착시스템의 primer와 bonding resin을 도포하고 Aelitefil 복합레진으로 접 착시 킨후 항온조에서 24시간 방치한 뒤 인장접착강도를 측정하고, 상아질표면 및 파단면의 양상을 주사전자 현미경으로 관찰하였으며 FT-IR을 사용하여 전처리 전후의 상아질 표면을 분석하여 다음의 결과를 얻었다. 1. NTG-GMA/BPDM 계 상아질접착제 (All-bond 2)로 접착시킨 경우 물로 습윤시킨 대조군에 비해 0.1 % benzalkonium chloride 수용액으로 습윤시킨 군에서 유의하게 높은 인장접착강도를 보였으나(p<0.05), 0.5% 및 1.0 % benzalkonium chloride 수용액으로 습윤시킨 군에서는 유의한 차이가 나타나지 않았다. 2. DSDM계 상아질접착제 (Aelitebond) 로 접착시킨 경우 물로 습윤시킨 대조군과 0.1 %, 0.5% 및 1.0 % benzalkonium chloride 수용액으로 습융시킨 군 간의 인장접착강도의 유의한 차이는 없었다(p>0.05). 3. Benzalkonium chloride 수용액의 적용과 관계 없이 전체적으로 NTG-GMA/ BPDM계 상아질접착제로 접착시킨 경우가 DSDM계 상아질접착제로 접착시킨 경우보다 인장접착강도가 높았으며, 파단양상의 관찰결과에서도 NTG-GMA /BPDM계 상아질접착제를 사용한 경우는 응집성 및 혼합성 파단양상이, DSDM 계 상아질접착제를 사용한 경우는 부착성 파단양상이 우세하였다. 4. 주사전자 현미경적 관찰상에서 benzalkonium chloride 수용액 적용 유무에 따른 각 상아질 표면의 primer 도포양상의 뚜렷한 차이는 관찰되지 않았으나, 상아질 표면에 대한 benzalkonium chloride 수용액 적용 전후의 FT-IR 분석결과 에서는 0.1 % benzalkonium chloride 수용액으로 습윤 처리 시킨 군이 대조군에 비해 NTG-GMA/ BPDM 및 DSDM primer의 도포효과를 다소 향상시킨 소견이었다.

  • PDF