• 제목/요약/키워드: All-In-One

검색결과 24,904건 처리시간 0.051초

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

개심술 113예에 대한 임상적 고찰 (Clinical experience of open heart surgery -113 cases-)

  • 진성훈
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.270-280
    • /
    • 1987
  • One hundred thirteen cases of open heart surgery were performed in the department of thoracic and cardiovascular surgery of Inha General Hospital from April 1986 to April 1987. There were 73 cases of congenital heart disease and 40 cases of acquired valvular heart disease, including one redo case respectively. The technique of deep hypothermia with circulatory arrest was used widespreadly for infants and small children, and early extubation was performed as possible in the great number of all cases. There were three operative deaths [2.7%], all in congenital cases, and three follow-up deaths, all in acquired cases.

  • PDF

대동맥동 동맥루 파열 -수술치험 6예- (Ruptured Aneurysm of Aortic sinus of Valsalva -A Report of 6 Cases-)

  • 이종명
    • Journal of Chest Surgery
    • /
    • 제7권2호
    • /
    • pp.201-208
    • /
    • 1974
  • The purpose of this paper is to present author's experience with 6 cases of ruptured aneurysm of sinus of Valsalva which were treated surgically during last 10 years. Among the 6 cases, 5 were male and one was female. All of them originated from the right coronary sinus and 5 cases were ruptured into the RV while remained one into RA. The diagnosis was obtained in 4 cases by cineangiocardiogram. Clinically, we had difficulties in differential diagnosis with combined cases of VSD with A.I. and had special experience in its differentiation during cardiac catheterization. By simultaneous trans-venous and trans-arterial catheterization, identified two catheter tips in the RV, and pull back tracing obtained aortic pressure directly from RV, and RA from RV pressure which were benefit in confirm ruptured aneurysm of the aortic sinus. Surgical correction was performed by means of direct suture closure or combined Teflon pledget Of patch enforcement graft after aneurysm resection by trans-RA or trans-RV approach. All patients had no history of bacterial endocarditis, syphilis, or tuberculosis and operative findings revealed intact coronary sinus except involved one moreover 3 cases combined with high VSD which uggested congenital in origin although pathologic reports revealed only fibrosis. Post-operative course were uneventful in all cases but one who had bleeding and 2 months to 9 years follow up results were good and spend their usual life in all cases.

  • PDF

스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구 (A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device)

  • 박준현;호예지;이예림;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

End-burning 고체추진기관 적용 일체형 연소관 내열재 개발 (Development of All-in-one Case Insulation for the End-burning Solid Rocket Motor)

  • 김진용;이선재;최지용;박재범;이상연
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1045-1047
    • /
    • 2017
  • 본 연구는 고체 추진기관에 적용되는 내열재를 기존의 autoclave 공법이 아닌 hot press molding을 포함한 B/D 성형공법으로 제작하는데 초점을 두고 있다. EPDM/kevlar를 기본 조성으로 내열재 원료가 구성된다. 우선 부츠 내열재는 금형을 사용하여 가황 상태로 제작한다. 연소관에 일체형 내열재로 성형하기 위하여 두 개의 내열재 사이에 테이프를 삽입하였고, bladder를 사용하여 압력과 온도를 상승시켜 제작하였다.

  • PDF

A quantitative analysis about microleakage of all-in-one adhesive

  • Kang, Yong-Hee;Shin, Dong-Hoon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.574-574
    • /
    • 2003
  • I. Objectives Newly all-in-one adhesives were developed for reducing the techique sensitivity and chair time, but lots of concerns were made on bondability, longevity, and microleakage. The object of this study was to measure micro leakage and marginal quality of all-in-one adhesives using electrochemical method and SEM analysis quantitatively. II. Materials and Methods After making Class V cavities, they were bulk filled with Heliomolar(#A1) after surface treatment with three adhesives:Adper Prompt (Group 1), One up bond F (Group 2), Xeno III(Group 3).(omitted)

  • PDF

Benzalkonium Chloride가 BPDM/HEMA계 접착제의 상아질 접착에 미치는 영향 (EFFECT OF BENZALKONIUM CHLORIDE ON DENTIN BONDING WITH BPDM/HEMA SYSTEM)

  • 권병균;안식환;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.569-584
    • /
    • 1996
  • The purpose of this study was to elucidate the effect of benzalkonium chloride on tensile bond strength of BPDM/HEMA dentin bonding. One hundred sixty dentin specimens from freshly extracted bovine mandibular incisors were used, and 0, 0.02, 0.1 or 0.5% benzalkonium chloride solution was applied to the dentin specimen with/after phosphoric acid. 32% phosphoric acid was used when the specimens were bonded with One-Step$^{TM}$, a BPDM/HEMA system and 10% was used when bonded with All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system. Aelitefil$^{TM}$ composite resin was bonded to the pretreated dentin specimen with the use of All-Bond$^{(R)}$ 2 or One-Step$^{TM}$ dentin bonding agent. After the bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strength was measured. The fractured dentin specimens were examined under the scanning electron microscope. The results were as follows : Benzalkonium chloride application after acid-treatment resulted in decrease of dentin bond strength of One-Step$^{TM}$, a BPDM/HEMA system (p>0.05). Benzalkonium chloride application did not exert any influence on dentin bond strength of All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system (p>0.05). There was no relationship between the concentration or application method of benzalkonium chloride and the dentin bond strength of One-Step$^{TM}$ or All-Bon$^{(R)}$ 2 (p<0.05). On SEM examination of the fractured dentin-resin interface, while mixed failure was prominent in dentin bonding with One-Step$^{TM}$, adhesive and mixed failures were seen together in dentin bonding with All-Bond$^{(R)}$ 2 regardless of the concentration and application method of benzalkonium chloride.

  • PDF

Effect of additives and filling methods on whole plant corn silage quality, fermentation characteristics and in situ digestibility

  • Jiao, Ting;Lei, Zhaomin;Wu, Jianping;Li, Fei;Casper, David P.;Wang, Jianfu;Jiao, Jianxin
    • Animal Bioscience
    • /
    • 제34권11호
    • /
    • pp.1776-1783
    • /
    • 2021
  • Objective: This project aimed to evaluate the effects of both different additives and filling methods on nutritive quality, fermentation profile, and in situ digestibility of whole plant corn silage. Methods: Whole plant corn forage harvested at 26.72% dry matter (DM) was chopped and treated with two filling methods, i) fill silos at one time (F1), ii) fill silos at three times (F3), packing samples into one/three silo capacity at the first day, another one/three capacity at the second day, then one/three at the third day, three replicates. For each replicate, samples were treated with three additives, i) control (CTRL, no additive), ii) Sila-Max (MAX, Ralco Nutrition Inc., Marshall, MN, USA), and iii) Sila-Mix (MIX, Ralco Nutrition Inc., USA). With three replicates of each secondary treatment, there were nine silos, 54 silos in total. Each silo had a packing density of 137.61 kg of DM/m3. All silos were weighed and stored in lab at ambient temperature. Results: After 60 d of ensiling, all items showed good silage fermentation under MAX filled one time or three times (p<0.01). Higher silage quality for all additives was obtained at filling one time than that filled three times (p<0.01). The highest DM and lowest DM loss rate (DMLR) occurred to MAX treatment at two filling methods (p<0.01); Digestibility of acid detergent fiber, neutral detergent fiber (NDF), and curde protein had the same results as silage quality (p<0.01). Yield of digestible DM and digestible NDF also showed higher value under MAX especially for filling one time (p<0.05). Conclusion: All corn silages showed good fermentation attributes (pH<4.0). The forage filled one time had higher silage quality than that filled three times (p<0.01). MAX with homofermentative lactic acid bacteria enhanced the lactic acid fermentation, silage quality and nutrient digestibility, and so improved the digestible nutrient yield.

공개키 암호 시스템을 위한 LFSR 곱셈기 설계 (Design of LFSR Multipliers for Public-key Cryptosystem)

  • 이진호;김현성
    • 한국산업정보학회논문지
    • /
    • 제9권1호
    • /
    • pp.43-48
    • /
    • 2004
  • 본 논문에서는 GF(2m)상에서 Linear Feedback Shift Register 구조기반의 새로운 구조를 제안한다. 먼저 모듈러 곱셈기와 제곱기를 제안하고, 이를 기반으로 곱셈과 제곱을 동시에 수행할 수 있는 구조를 설계한다. 제안된 구조는 기약다항식으로 모든 계수가 1인 속성의 All One Polynomial 을 이용한다. 제안된 구조는 구조복잡도면에서 기존의 구조들보다 훨씬 효율적이다. 제안된 곱셈기는 공개키 암호의 핵심이 되는 지수기의 구현을 위한 효율적인 기본구조로 사용될 수 있다.

  • PDF

심장종양 6례 보고 (Cardiac Tumors)

  • 김병주
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.667-672
    • /
    • 1985
  • Primary cardiac tumors are uncommon in all age group. In contrast, tumors metastatic to the heart are significantly more common. On rare occasions, tumor may extend into the heart chamber via inferior vena cava from other parts of the body, such as liver, kidney, and uterus cava. With recent advancement in diagnostic imaging modalities and surgical techniques, cardiac tumors are now potentially curably form of heart disease. The most important factor in diagnosing the tumor is a high index of clinical suspicion. Six patients underwent surgical removal of intracardiac tumor during a 5-year period. The mean age of the 4 women and two men was 40 years [range 23 to 60]. All patients were operated on in the last five years of the studied period. All patients had symptoms varying in duration from 1 month to 4 years [average 13 months]. 2-Dimensional echocardiography contributed most to preoperative diagnosis, confirming presence of an intracardiac tumor in all examined patients. Of the six intracardiac tumor, 5 were myxomas [4 left atrial and 1 right ventricular] and one right atrial metastasis from hepatocellular carcinoma of the liver. In all cases, tumor masses were successfully excised. One patient expired after the operation on account of low cardiac out-put syndrome. Remained one patient among six, tumor mass extended into RA and RV with a stalk via IVC. On later follow-up study showed cold area on liver scan [hepatocellular ca.], so she was transferred to internal medicine, department for chemotherapy. Follow up results showed no signs of tumor recurrence in 4 myxoma cases.

  • PDF