• 제목/요약/키워드: All ceramic system

검색결과 236건 처리시간 0.031초

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

Structural, Dielectric and Field-Induced Strain Properties of La-Modified Bi1/2Na1/2TiO3-BaTiO3-SrZrO3 Ceramics

  • Hussain, Ali;Maqbool, Adnan;Malik, Rizwan Ahmed;Zaman, Arif;Lee, Jae Hong;Song, Tae Kwon;Lee, Jae Hyun;Kim, Won Jeong;Kim, Myong Ho
    • 한국재료학회지
    • /
    • 제25권10호
    • /
    • pp.566-570
    • /
    • 2015
  • $Bi_{0.5}Na_{0.5}TiO_3$ (BNT) based ceramics are considered potential lead-free alternatives for $Pb(Zr,Ti)O_3$(PZT) based ceramics in various applications such as sensors, actuators and transducers. However, BNT-based ceramics have lower electromechanical performance as compared with PZT based ceramics. Therefore, in this work, lead-free bulk $0.99[(Bi_{0.5}Na_{0.5})_{0.935}Ba_{0.065}]_{(1-x)}La_xTiO_3-0.01SrZO_3$ (BNBTLax-SZ, with x = 0, 0.01, 0.02) ceramics were synthesized by a conventional solid state reaction The crystal structure, dielectric response, degree of diffuseness and electric-field-induced strain properties were investigated as a function of different La concentrations. All samples were crystallized into a single phase perovskite structure. The temperature dependent dielectric response of La-modified BNBT-SZ ceramics showed lower dielectric response and improved field-induced strain response. The field induced strain increased from 0.17%_for pure BNBT-SZ to 0.38 % for 1 mol.% La-modified BNBT-SZ ceramics at an applied electric field of 6 kV/mm. These results show that La-modified BNBT-SZ ceramic system is expected to be a new candidate material for lead-free electronic devices.

시멘트 공간이 적층 가공으로 제작한 지르코니아 하부구조물의 변연 및 내면 적합도에 미치는 영향 (Effect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing)

  • 민지원;김세연;김재홍
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Purpose: The goal of this study was to determine the clinical acceptability of various cement space settings for the marginal and internal fit of a zirconia core manufactured using additive manufacturing. Methods: The maxillary right incisor served as the master model. After scanning the maxillary right incisor with a dental 3D (three-dimensional) scanner, the stereo lithography file was created using different cement space settings of 40, 120, and 200 ㎛ using computer-aided design software (Dental System 2018; 3Shape). The marginal and internal fit of the 3 groups were determined using the silicon replica technique. Measurement points were divided into the following three categories: margin, axial wall, and incisal. To ensure more accurate measurements, these three measurement points were divided into 8 points. The Shapiro-Wilk, one-way ANOVA, and Tukey's honestly significant difference test (for all tests α=0.05) were the statistical analyses that were included in the study. Results: The CS (cement space)-200 group had better marginal and internal fit than the CS-40 and CS-120 groups, and there were statistically significant differences at the marginal and incisal points, except for the axial wall points. CS-200 group, both marginal and internal fit were within 120 ㎛, which is the clinically acceptable value. Conclusion: This study suggests that a 200 ㎛ cement space setting is ideal for optimal marginal and internal fit of 3D-printed ceramic crowns.

물질수지를 이용한 A2O 고정생물막법에서의 호기탈질평가 (Evaluation of Oxic Denitrification in A2O Fixed Biofilm System through Mass Balance)

  • 윤조희;박승환;이상훈;김승현
    • 대한환경공학회지
    • /
    • 제22권2호
    • /
    • pp.231-239
    • /
    • 2000
  • 본 연구는 $A_2O$ 공정을 적용한 고정생물막법을 이용하여 고농도의 총무기성질소(TIN) 유입으로 인해 C/N비가 낮은 폐수를 처리하기 위하여 최적의 운전조건 탐색과 생물학적 호기탈질을 평가하였다. 혐기조와 무산소조에 세라믹 여재를 그리고 호기조에 PVC 여재를 충전한 실험장치는 C/N(TOC/TIN)비를 0.5로 일정하게 유지하고 알칼리도를 변화시켜 실험을 실시하였으며 그 결과는 다음과 같다. 유기물제거는 운전조건에 관계없이 96.0% 이상의 높은 제거효율을 얻었다. 유입수의 알칼리도를 약 1210mg/L(Run 5)로 운전하였을 때, $NH_4{^+}-N$와 총 질소 평균 제거효율은 각각 93.5%, 81.8%이었으며, 제거된 총 질소 중 64.9%가 호기조에서 생물학적 탈질에 의해서 제거되었다. 호기조에서 물질수지를 이용하여 질소와 알칼리도를 분석한 결과, 1mg의 $NO_2{^-}-N$가 탈질에 의해 제거될 때 2.49~3.46mg의 알칼리도가 생성되었다. 호기조에서의 생물학적 탈질은 ${\Delta}TOC/{\Delta}DEN$의 이론적인 비 1.22보다 낮은 0.84(Run 5)에서 일어났다.

  • PDF

PLS 선형가속기 진공계의 운전특성 (Operatonal characteristics of the PLS linac vacuum system)

  • 김임경;박용정;김경렬;남궁원
    • 한국진공학회지
    • /
    • 제5권4호
    • /
    • pp.269-277
    • /
    • 1996
  • PLS 선형가속기 진공계는 클라이스트론 첨두출력 54MW, 펄스폭 4.1$\mu \textrm s$, 반복율 10Hz의 마이크로파 전력 공급상태에서 $2.6\times 10^{-6}$Pa의 진공도를 유지하고 있으며 $45^{\circ}C$ 운전조건에서 마이크로파 전력이 공급되지 않았을 때 진공도는 $2.4\times 10^{-6}$Pa이다. 설치 초기에 $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$이었던 가스방출율은 각 가속단위마다 약 140 GJ의 마이크로파 에너지가 전파된 현재 $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$이다. 주 장비로 사용중인 이온펌프는 모두 포화된 상태이며 60 l/s, 120 l/s, 230 l/s 이온펌프의 유효배기속도는 운전 영역에서 각각 45 l/s, 65 l/s, 140 l/s이다. 진공계 운전중 야기된 문제점들로는 이온펌프 및 진공 게이지 전원제어기의 오동작, 에너지 배가장치의 출력창, 전자총 및 가속관 종단부하의 진공누출 등이었다. 최근 일년간 총 41회에 140.8시간 운전 중지를 경험하여 98%의 가용도(availability)를 나타내었다. 추후 시험중인 도파관 밸브와 개발중인 가속관 종단부하가 설치된다면 가용도를 99.5% 이상으로 증가시킬 수 있을 것으로 기대한다.

  • PDF

CaCO3, CaCl2 및 CaSO4 · 2H2O 첨가에 의한 AFm상의 변화 (A Conversion of AFm Phases by Addition of CaCO3, CaCl2 and CaSO4 · 2H2O)

  • 이종규;추용식
    • 한국세라믹학회지
    • /
    • 제40권1호
    • /
    • pp.24-30
    • /
    • 2003
  • AFm상의 생성과 전이는 시멘트에서의 수화반응, 경화속도 그리고 내구성에 큰 영향을 미친다. 실험실에서 제조한 3종류의 대표적인 AFm상에 CaC $O_3$, CaC $l_2$ 및 CaS $O_4$.2$H_2O$를 첨가하였을 때의 상변화를 검토를 하였다 AFm상의 상전이는 각 수화물의 용해도적과 밀접한 관계가 있다. 각종 AFm상( $M_{S}$ , $M_{C}$, $M_{Cl}$ )에 CaS $O_4$.2$H_2O$를 첨가한 경우, 모든 경우에서 AFm상은 ettringite로 전이를 하였다. 전이의 순서는 $M_{S}$ 가 가장 빠르게 ettringite로 전이를 하였으며 $M_{Cl}$ 이 가장 늦게 전이를 하였다. CaC $O_3$를 AFm상에 첨가하였을 경우에는 $M_{S}$ 는 보다 안정한 상인 $M_{C}$로 전이를 하였으며, 또 $M_{S}$ 중의 S $O_4$$^{2-}$ 이온이 방출되어 ettringite가 생성된다. $M_{C}$$M_{Cl}$ 에 CaC $O_3$를 첨가한 경우에는 아무런 상 변화가 일어나지 않았다. CaC $l_2$를 AFm상에 첨가하였을 경우, $M_{S}$$M_{Cl}$ 로 전이를 하였으며, $M_{S}$ 중의 S $O_4$$^{2-}$ 이온이 방출되어 ettringite가 생성된다. $M_{C}$에 CaC $l_2$를 첨가한 경우 $M_{C}$는 완전히 $M_{Cl}$ 로 전이를 하였다. $M_{Cl}$ 에 CaC $l_2$를 첨가하였을 경우에는 아무런 수화물의 변화는 발생하지 않았다. 따라서 CaS $O_4$.2$H_2O$를 CaC $O_3$및 CaC $l_2$와 반응시켰을 때의 AFm상의 안정성 순서는 $M_{S}$ < $M_{C}$< $M_{Cl}$ 로 된다.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

In-Ceram 전부도재관의 shoulder 폭경에 따른 변연적합도 (Marginal fit of In-Ceram crown according to shoulder width)

  • 천승근;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.105-112
    • /
    • 2000
  • 본 연구는 치아형성시 shoulder 폭경이 변연 적합도에 미치는 영향을 평가하기 위해 시행하였다. 지대치의 치경부쪽의 shoulder 폭경을 0.6 mm, 0.9 mm, 1.2 mm로 나누어 각각 9개씩, 총 27개의 모형을 제작하여 통법에 따라 In-Ceram 전부 도재관을 제작한 후 시멘트 접착하고 근심, 원심, 협, 설측 중앙 부위를 200배 확대하여 변연 적합도의 측정한 후 각 군과, 측정부위에 따른 변연 적합도 비교해 본 결과 다음과 같은 결론을 얻었다. 1. shoulder 폭경이 0.6 mm인 경우 $81.28{\mu}m$, 0.9 mm인 경우는 $70.78{\mu}m$, 1.2mm 인 경우는 $67.75{\mu}m$의 변연간극을 보였다. 2. shoulder 폭경이 0.6 mm인 경우가 0.9 mm, 1.2 mm인 경우보다 변연간극이 유의한 차이를 크게 나탔났으며(p<0.05), 0.9 mm인 경우와 1.2 mm인 경우는 유의한 차이가 없었다(p>0.05). 3. In-Ceram 시편의 변연부에서 근심측, 원심측, 순측, 설측의 측정위치에 따른 변연적합도의 비교시 유의한 차이가 없었다(p>0.05).

  • PDF

Fe(NO3)3 수용액의 농도와 침지시간에 따른 지르코니아의 색상 및 특성 변화 (The change of color and physical properties of zirconia according to the variation of concentration and dipping time of Fe(NO3)3solution)

  • 서정일;박원욱;고재숙
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.281-290
    • /
    • 2016
  • Purpose: The increased aesthetic requirements and demands of patients have resulted in the developments of coloring liquid for zirconia. Methods: In this study, zirconia block was dipped into $Fe(NO_3)_3$solution, which showed a color and then concentration of $Fe(NO_3)_3$and zirconia's color and physical properties depending on the dipping time were observed and compared with exclusive coloring solutions. As the result, the following conclusions were obtained. Results: When compared with the specimens that were colored using exclusive solutions, $L^*$ value rose overall depending on the concentration of $Fe(NO_3)_3$and $a^*$ value was red in the form of (+) in all the specimens. Also, $b^*$ value was in the form of (+) at 0.5 to $1{\ss}fl$, but was in the form of (-) at 1.5 to $2{\ss}fl$. The dipping time did not highly influence $L^*$ value, but $a^*$ value and $b^*$ value were directly opposite to the specimens, which were not colored, except the sample that was dipped for only 2 seconds. When compared with exclusive coloring solutions, $Fe(NO_3)_3$had the most similar color at 0.5 to $1{\ss}fl$ and the longer the coloring time, the higher the rate of color change became. In relation to the density change depending on the addition of $Fe(NO_3)_3$, there was the lowest density at $2{\ss}fl$ and the density was increased in the specimens that were not colored. Conclusion: These results show that $Fe(NO_3)_3$solution can be used to make colored zirconia. It is expected that newly made colored zirconia can be used in clinical practice because the colored zirconia not only possesses the mechanical properties that all ceramic core material should have but also was biocompatible to a living cells.

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.