• Title/Summary/Keyword: All Air

Search Result 3,831, Processing Time 0.036 seconds

Oceanography in the Waters Adjacent to Kamchatka and Kurile islands in the Northwestern Pacific - II (북서태평양 명태 어장의 해황 - 2 . 기후의 특성 -)

  • Han, Young-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.13 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • For four calender years (1971-1974), daily observations of weather conditions (air temperature, humidity, wind speed, wind direction, cloud amount, fog, precipitation etc.) at six stations in the north western Pacific Ocean are used to calculate mean monthly values and to check extra-conditions. At Petropavlosk and Miko'skoe, where indicate the characteristics of modified continental climate, the temperature and humidity are high in summer, and Iow in winter. At A Dak and She Mya, where indicate the characteristics of warm current type maritime climate, humidity is high in all season and annual range of air temperature is nearly negligible. At Simusir and Vasi!' eva, where indicate the characteristics of cold current type maritime climate, humidity is high in all season and annual range of air temperature is $15^{\circ}C.$ As dry cooling power is relatively high in winter, working condition on deck is bad. Most of fogs are advection fog in the area of cold current type climate in summer.

  • PDF

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

Comparison of Exposure Estimation Methods on Air Pollution of Residents of Industrial Complexes (광양만권 주변지역 주민들의 대기오염 노출추정을 위한 방법론 비교 연구)

  • Jung, Soon-Won;Cho, Yong-Sung;Yang, Won-Ho;Yu, Seung Do;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.151-161
    • /
    • 2013
  • The assessment of personal exposure is a critical component in population-based epidemiologic studies of air pollution. This study was conducted to apply and compare the four exposure estimation methods of individual-level to air pollution concentration in a cohort including 2,283 subjects in Gwangyang, Korea. Individual-level exposure of air pollution were estimated using multiple approaches, including average across all monitors, nearest monitor, and spatial interpolation by inverse distance weighting and kriging. The mean concentrations of $PM_{10}$, $NO_2$, $SO_2$, CO, $O_3$ by four exposure estimation methods were slightly different but not significantly different from each other. Cross-validation showed that kriging was more accurate than other exposure estimation methods because kriging has probably predicted individual exposure levels equivalent to residential locations after estimating the parameters of a model according to the spatial surface of air pollution concentration. These data support that spatial interpolation methods may provide better estimates than selecting the value from the nearest monitor and averaging across values from all monitors by reflecting spatial attributes of air pollution on personal level.

A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions - (한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 -)

  • Song, Min-Kyu;Kwon, Seo-Yoon;Jung, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.14 no.4
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.

Air in the Left Brachiocephalic Vein Accompanied with Pulmonary Edema (폐부종을 동반한 왼팔머리정맥 내의 공기 음영)

  • Lee, Sung Won;Kang, Hyeon Hui;Kim, Min Hee;Kwon, Hyuk Min;Lee, Ji Myoung;Lee, Jong Yul;Oh, Su Jin;Lee, Sang Haak;Moon, Hwa Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.1
    • /
    • pp.57-60
    • /
    • 2008
  • A fifty-seven year old female patient visited the emergency department with tachypnea and a decreased mental status. The patient had been receiving fluid therapy at home and a bolus of air was injected into the fluid bottle in order to increase the infusion speed. Chest computed tomography revealed air in the left brachiocephalic vein that was accompanied with pulmonary edema the diagnosis of venous air embolism was made. Venous air embolism can result from various procedures that are performed in almost all clinical specialties and they can be fatal in cases of massive air embolism. Therefore, it is important for all clinicians to be aware of this problem.

Estimation of Air Pollutant Emission Factors for Motorcycle (이륜자동차의 대기오염물질 배출계수 산정을 위한 연구)

  • Lim, Jae-Hyun;Kim, Hyun-Min;Lee, Sang-Moon;Kang, Hee-Jun;Lim, Yoon-Sung;Seo, Choong-Yeol;Kim, Jong-Choon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2010
  • While increased use of motor cycles in the recent years for various demands could worsen air quality, only few studies have been conducted on estimation of emission factors and characterization of emissions from motorcycle. In this study, emissions from selected six models of motorcycle based on largest market share and production rate were investigated. To investigate gaseous and carbonaceous air pollutants, such as carbon monoxide (CO), total hydrocarbon (THC), nitrogen oxide ($NO_x$), elemental carbon (EC) and organic carbon (OC), total 124 motorcycles between 2003 and 2007 model year were tested with regulatory driving conditions, such as CVS-40 and CVS-47 mode. These motorcycles were further sub-categorized based on their displacement (< 50 cc, 50~150 cc, and $\geq$ 150 cc), type of stroke (2- and 4 strokes) and model year (2003~2005 and 2006~2007). Tested motorcycles with recent model year (2006~2007) exhibited less emissions of regulatory gaseous and carbonaceous air pollutants compared to old model year (2003~2005). Chemical analysis showed that CO present in highest concentration followed by THC and $NO_x$ for all tested motorcycles. Interestingly, two strokes motorcycle produced higher THC emission but less CO and $NO_x$ than those of four strokes. For all types of displacement and stroke, emission factors (gram per kilometer) of THC and CO except $NO_x$ with recent model year (2006~2007) showed decreased trend compared to old model year (2003~2005). In addition to this, due to mixed combustion between gasoline fuel and lubricant, two strokes motorcycle showed OC > EC emission trend.

THE EFFECTS OF SURFACE TREATMENT AND THERMOCYCLING ON THE MICROLEAKAGE OF COMPOSITE RESIN CORES (치아표면 처리방법과 thernocycling이 콤포짓트 레진 코어의 미세누출에 미치는 영향)

  • Lim, Yong-Chul;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.255-263
    • /
    • 2000
  • The purpose of this study was to compare the microleakage of the composite resin cores according to surface treatment, dentin bonding agents, and thermocycling. For this study, 120 extracted premolar teeth were used. Flat occlusal surfaces were prepared with diamond disk, and treated with air-abrasion, acid-etching, combination. The composite resin core was built with Z-100 after application of Scotchbond Multi-Purpose and All-Bond 2. Prepared specimens were thermocycled for 2,000 cycles. Specimens were immersed in 1% methylene blue solution for 24hours at $37^{\circ}C$. The microleakage was measured with a inverted metallurgical microscope(BHS313, Olympus, Japan). The following conclusions were drawn from this study: 1. The microleakages in the groups treated with air-abrasion and with acid etching were greater than that of the groups treated with combination method before thermocycling(p<0.05), the microleakages of the groups treated with air-abrasion were greater than that of the groups treated with acid-etching and combination method after thermocycling(p<0.05) 2. There were no significant difference between groups using Scotchbond Multi-Purpose and the groups using All-Bond 2. 3. Thermocycling didn't affect the change of microleakage in all cases.

  • PDF

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete (콘크리트 공극 분석을 위한 평면간격계수의 제안)

  • Jeong, Won-Kyong;Choi, Sung-Yong;Kim, Sung-Hwan;Yun, Kyong-Ku
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

Comparison of the PMV and $CO_2$ Concentration, Energy Consumption Characteristics of Central Air-Conditioning System and System Air-Conditioner with Ventilation System for Large Space (중형공간에서 중앙공조방식과 시스템에어컨 방식에 따른 PMV와 $CO_2$농도, 에너지소비량 비교)

  • Sung, Sang-Chul;Noh, Kwang-Chul;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.298-303
    • /
    • 2008
  • PMV, $CO_2$ and the energy consumption performance were numerically investigated in a large space with air-conditioning systems of four type. The numerical results showed that thermal comforts in the occupied zone are nearly similar in three systems except 3-way wall type system air-conditioner with ventilation system installed 2.2m height from the bottom. In case of 3-way wall type system air-conditioner the energy consumption for cooling loads was reduced about 25.5% compared to other air-conditioning systems. From the viewpoint of IAQ, it was turned out that system air-conditioner with ventilation system became worse about 20% compared to central air-conditioning systems for cooling load. The PMV, $CO_2$ concentration and energy consumption of all systems for heating loads were similar in a large space considered.

  • PDF