• Title/Summary/Keyword: Alkaline Wastewater

Search Result 97, Processing Time 0.022 seconds

Natural Purification Treatment using Soil Brick with Combined Effective Microorganisms and Emergent Plants (복합유용미생물 및 수생식물을 활착시킨 흙블록을 이용한 자연정화 처리방법 연구)

  • Sim, Hagjae;Oh, Yongkeol;Park, Chulhwi;Kang, Wonsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.543-550
    • /
    • 2015
  • In this study, using soil brick with combined effective microorganisms and emergent plants was identified which it can increase the effect of conservation and improvement of water. Lab-test was consist of four kind of reactors and each of reactors were A(rawwater), B(soil brick), C(emergent plant) and D(soil brick+emergent plant). Iris pseudoacorus, Phargmites australis, Typha angustifolia and Zizania latifolia were used for emergent plant. Evaluation of application on various environment were performed on agricultural waterway and pond. The pH measurement test of soil brick was performed due to evaluate whether a strong alkaline water flows out of the soil brick. Result of lab-test, removal efficiency of D was better than removal efficiency of A presenting 20.9%, 27.9% 21.5%, 33.8% and 58.4% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Removal efficiency of soil brick on agricultural waterway was revealed to be 49.5%, 45.0%, 43.7%, 37.3% and 28.6% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. And removal efficiency of soil brick on the pond was revealed to be 12.7%, 10.5%, 9.32%, 10.4% and 36.3% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Result of pH measurement test of soil brick was neutral which was about 6 to 8.

Decomposition of Hexahydro-1,3,5-trinitro-1,3,5-triazine by Gamma Ray Irradiation (감마선 조사에 의한 hexahydro-1,3,5-trinitro-1,3,5-triazine(RDX)의 분해)

  • Lee, Byungjin;Lee, Myunjoo;Kim, Yuri
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.731-741
    • /
    • 2004
  • The purpose of this study was to evaluate the potential of a gamma ray irradiation to decompose hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in an aqueous solution. The decomposition reaction of RDX by gamma ray irradiation was a first-order kinetic over the applied initial concentrations (10-40mg/L). The dose constant was strongly dependent on the initial concentration of the RDX. The removal of RDX was more efficient at pH below 3 and at pH above 11 than at neutral pH (pH 5-9). The required irradiation dose to remove 99% of the RDX (40mg/L) was 4, 8 and 1 kGy, at pH 2, 7 and 13, respectively. The dose constant was increased by two folds and over twelve folds at pH 2 and 13, respectively, when compared with that at pH 7. When an irradiation dose of 20 kGy was applied, the removal efficiencies of TOC were 80, 57 and 91% at pH 2, 7 and 13, respectively. Ammonia and nitrate were detected as the main nitrogen byproducts of RDX and formic acid was detected as an organic byproduct. The results showed that a gamma ray irradiation was an attractive method for the decomposition of RDX in an aqueous solution and it was found that a strong alkaline pH over 12 should be applied to the decomposition reaction of RDX.

Mechanism of Removal of Cr(VI) Ions from Solution by Borosilicate Glasses Containing Alkaline Earth Oxides (알칼리토 금속산화물이 함유된 붕규산염계 유리를 이용한 용액 중 Cr6+ 이온 제거 기구)

  • Back, Il-Hee;Lim, Hyung-Bong;Kim, Cheol-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.222-227
    • /
    • 2011
  • The hexavalent chromium ions in wastewater are highly toxic chemicals even at low concentrations. It causes serious diseases, such as cancer, skin disease, digestive trouble et. al. In this study, $Cr^{6+}$ ions were removed by using borosilicate glasses. Various glasses system with different compositions were prepared and then reacted in a solution contaning $Cr^{6+}$ ions. After the reaction, the concentration of the $Cr^{6+}$ ions remained in the solution was measured by ICP-OES. The reacted surface of the glasses was also analyzed by using a XRD, SEM, and EDS. When $Na_2O-RO-SiO_2-B_2O_3$ (RO=MgO, CaO, SrO, BaO) glasses were reacted with a solution containing $Cr^{6+}$ ions, the optimum removal efficiency of $Cr^{6+}$ ions was observed in the BaO glass. $Ba^{2+}$ ions leached out of these glasses combine with $Cr^{6+}$ ions in a solution to form $BaCrO_4$ crystals on the glass surface. In this manner, the $Cr^{6+}$ ions can be removed from the solution. It is conceivable that $Ba^{2+}$ ions are reacted with $Cr^{6+}$ ions in a solution immedeately after leaching out of the glasses. The pH of the solution for optimum removal of $Cr^{6+}$ ions were 3.0~5.0.

Removal of Arsenic in Synthesis Method and Characteristics of Fe(III)-ettringite (비소제거를 위한 Fe(III)-ettringite 합성방법 및 특성 연구)

  • Hong, Seong-Hyeok;Park, Hye-Min;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Arsenic is one of the most abundant contaminant found in waste mine tailings, because of it's carcinogenic property, the countries like United states of America and Europe have made stringent regulations which govern the concentration of arsenic in drinking water. The current study focuses on different treatment methods for removal of arsenic from waste water. Treatment method the high strength arsenic waste water is treated with Fe(III)-ettringite by co-precipitation method. Number of experiments were carried out to decide the optimal dosage of Fe(III)-ettringite to treat arsenic waste water. The Fe(III)-ettringite was synthesized by taking appropriate equivalent ratios of calcium oxide and ferric chloride in proportion to the arsenic. The best removal efficiencies of 94% were observed at a As/(Ca: Fe) ratio of 1:3. The maximum removal of arsenic was observed in pH range of 12. But as the pH increases the arsenic removal efficiency decreases as portlandite is formed in the pH above 12. The analysis of surface of precipitate conform the needle like structure of ettringite. This treatment technique has promising features such as, the chemicals required in the treatment as well as the sludge generated can be reduced. The operating pH range is in alkaline region which is advantageous over traditional treatment process which has lower pH. Also the co-precipitation not only helps in removal of arsenic but also heavy metals.

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

Charateristics of Akalophilic Microorganism Developed for Color Removal of Dye (염료의 색도 제거를 위해 개발된 호알칼리성 미생물의 특성)

  • Lee, Hyun-Wuk;Lim, Dong-Joon
    • Textile Coloration and Finishing
    • /
    • v.22 no.2
    • /
    • pp.145-154
    • /
    • 2010
  • An alkalophilic microorganism capable of degrading dyes was developed for the treatment of alkaline dye solution. This strain was identified as Pseudomonas species. Using this microorganism, biological treatment of dye was studied in Erlenmeyer flasks. The characteristics of this microorganism were observed under various incubating-condition such as temperature, pH, nitrogen source, and macronutrients concentration. The removal effciencies of Disperse Red 60 from synthetic wastewater were 33.5 ~ 36.9% at the range of $30{\sim}40^{\circ}C$, and they were 31.1 ~ 36.7% at the range of initial pH 8 ~ pH 10, respectively. The optimal culture medium was found to be 0.25%(w/v) yeast extract, 0.25%(w/v) polypeptone, 0.1%(w/v) $KH_2PO_4$, 0.2%(w/v) $MgSO_4{\cdot}7H_2O$, and 1.0%(w/v) $Na_2CO_3$. In treatment of various dyes using Erlenmeyer flasks, the removal effciencies of Disperse Blue 87, Disperse Yellow 64, Disperse Red 60, Acid Blue 193, Acid Red 138, and Direct Yellow 23 were found to be 76%, 71%, 58%, 93%, 94%, and 90% respectively after 24hrs reaction of alkalophilic strain Pseudomonas sp. YBE-12.

The pH as a Control Parameter for Oxidation-Reduction Potential on the Denitrification by Ochrobactrum anthropi SY 509

  • Kim, Sung-Hong;Song, Seung-Hoon;Yoo, Young-Je
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.639-642
    • /
    • 2004
  • The pH as a control parameter for oxidation-reduction potential (ORP) was investigated through the denitrification by Ochrobactrum anthropi SY509 under non-growing condition. The optimal pH of nitrate reductase was 7.0, and the minimal ORP level was -250 mV for the denitrification under aerobic condition. In the case of anaerobic condition, the optimal pHs of nitrate and nitrite reductase were shifted to 10.0 and 9.0, respectively, and the minimal ORP levels of nitrate and nitrite reductase were decreased to -370 mV and -340mV, respectively. In the case of alkaline pH and anaerobic condition, the denitrification efficiency of nitrate was increased up to about 2-fold over that of neutral pH and anaerobic condition. Therefore, the combined control of pH and ORP in the anaerobic condition is shown to be an important parameter in the biological denitrification process.

Characteristics of Acid Fermentation and Alkali Pretreatment of Organic Wastes (유기성 폐기물의 산발효 특성 및 알카리 전처리에 관한 연구)

  • 박종안;허준무
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.108-116
    • /
    • 2001
  • It is difficult to task to achieve high biological nutrient removal from municipal wastewater because of low organic content. Volatile fatty acids(VFAs) produced from acid fermentation of food wastes can be utilized as external carbon sources for the biological nutrient process. Significant reduction and stabilization of the food wastes can also be obtained from the acid fermentation. The objective of this study is to evaluate characteristics of acid fermentation of the food wastes. Results obtained from the batch experiment of various organic wastes showed that the food wastes had high potential to be used as an external carbon source because of the largest production of the VFAs with low nitrogen and phosphorus content. The fish waste was found to be the next possible organic waste, while the others such as radish cabbage and molasses waste showed high VFAs consumption potential as a results of high nitrogen and phosphorus content. alkaline hydrolysis of the food waste was carried out using NaOH prior to the acid fermentation. As the alkali addition increased, solubilization of the organics as well as TSS reduction increased. However, fraction of soluble COD to total COD became stable after a sharp increase. Alkali addition greater than 0.5g NaOH per g TS resulted in significant increase in pH.

  • PDF

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.